EFFECTIVENESS OF ULTRASOUND AND CLINICAL SCREENING OF AT-RISK NEWBORN BABY HIPS



Abstract

Of the 30585 births (from 1997–2002) in the population served by our NHS trust, 2742 babies (8.96%) were referred to the hip screening clinic by the neonatologists and general practitioners. They were examined clinically and by US scans by the specialist consultants. The findings were documented prospectively. 233 hips were identified as abnormal by ultrasound scans (Graf). 45% (106) of these were normal on clinical examination. None of the hips identified as abnormal on clinical examination were normal on US scans. In 38% (88) clinical examination could not be reliably performed as the babies were tense.

Of the 1862 hips which were clinically normal, 106 (5.69%) had abnormal ultrasound findings. Furthermore, of the 841 babies who were tense on clinical examination, 88 (10.46%) babies had abnormal ultra-sonographic findings.

Ultrasound scanning of hips in at-risk babies by an experienced paediatric radiologist will identify all the abnormal hips. This will release the paediatric orthopaedic surgeon from routine clinical examination of all these babies. This time can be utilised for running other clinics. Babies found to have abnormal hips on US scanning may be seen by the orthopaedic surgeon for treatment and follow-up. Parents of babies with normal hip US scans may be reassured by a nurse practitioner or a paediatric physiotherapist.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom