LONG-TERM OUTCOME AFTER ARTHROSCOPIC ACROMIOPLASTY FOR FULL THICKNESS TEARS OF THE ROTATOR CUFF



Abstract

Purpose: The purpose of this study was to assess long-term functional outcome after arthroscopic acromioplasty for full-thickness rotator cuff tears, to evaluate the efficacy of complementary procedures (biceps tenotomy, extended acromioclavicular resection), and to examine the course of anatomic lesions.

Material and methods: From 1988 to 1994, 141 full-thickness rotator cuff tears were treated by arthroscopic acromioplasty. Ninety-eight patients, mean age 60 years, were reviewed clinically, radiographically, and sonographically at more than eight years. The mean preoperative Constant score was 48.5 points. The tear involved the supraspinatus in 18 cases, the supraspinatus and infraspinatus in 40, the supraspinatus and the subscapularis in ten, and all three tendons in 20. Coronal extension showed a distal tear in four, an intermediate tear in 52, and a retracted stump in 32. Systemic acromioplasty was associated in 36 patients with tenotomy of the long head of the brachial biceps and in 44 with acromioclavicular extension.

Results: At mean follow-up of 10.7 years (8–13.5), the mean Constant score was 60 points. The clinical outcome was excellent or good in 39.7%, fair in 45.5%, and poor in 14.8. 62.5% of the patients were satisfied or very satisfied. The height of the subacromial space was 5.19 mm at last follow-up compared with 4.3 mm preoperatively. The antalgesic effect of biceps tenotomy was significant when the initial acromiohumeral space was less than 5 mm. This procedure did not produce any significant change in the subacromial height or development of osteoarthritis at last follow-up. Sonography showed stability of the size of the tear in 83.8% of the cases. The results were significantly less satisfactory when the initial tear involved the subscapularis or all three tendons.

Conclusion: The clinical results of arthroscopic acropmioplasty for full-thickness tears show long-term stability. Biceps tenotomy improves the antalgesic effect significantly, particularly if the subachromial space measures less than 5 mm preoperatively, without causing significant radiological degradation. Extension to the acromioclavicular level should be systematic in patients with acromioclavicular pain preoperatively and/or radiological anomalies.