Abstract

The hips of 1000 newborn babies were examined clinically and by ultrasonography. The ultrasound assessment was based on measurements of the coverage of the femoral head by the bony acetabular roof, and this parameter was called the Bony Rim Percentage (BRP). The mean BRP was 55.3% in girls and 57.2% in boys, a significant difference. Clinical instability occurred in 0.7% of the newborn babies, and all of the unstable hips had a BRP below the lower limit of normal. All infants with normal clinical findings and suspected abnormal hips based on ultrasound were followed up; in all but two the hips became normal spontaneously. We conclude that ultrasonography, using the measurements of femoral head coverage, is appropriate for screening the newborn, is reliable in differentiating between a true and a false positive Ortolani sign, and that hip dysplasia which is not clinically demonstrable at birth can be detected by ultrasound. Ultrasound should replace radiography as the routine method of following up high-risk infants and those with suspicious signs.