General Orthopaedics

OUTCOMES OF CERAMIC BEARINGS AFTER PRIMARY THA IN THE MEDICARE POPULATION

The International Society for Technology in Arthroplasty (ISTA), 29th Annual Congress, October 2016. PART 2.



Abstract

Introduction

Previous registry studies of ceramic-on-polyethylene (C-PE) and ceramic-on-ceramic (COC) have focused on revision outcomes following primary surgery. Less is known about the effect of ceramic bearings on infection, dislocation, and mortality as outcomes following primary total hip arthroplasty (THA) for the Medicare population. We asked (1) does the use of C-PE bearings influence outcomes following THA as compared with metal-on-polyethylene (M-PE); and (2) does the use of COC bearings influence outcomes following THA as compared with M-PE?

Methods

A total of 315,784 elderly Medicare patients (65+) who underwent primary THA between 2005 and 2014 with known bearing types were identified from the Medicare 100% inpatient sample administrative database. Outcomes of interest included relative risk of 90-day readmission, infection, dislocation, revision, or mortality at any time point after primary surgery. Propensity scores were developed to adjust for selection bias in the choice of bearing type at index primary surgery. Cox regression incorporating propensity score stratification (10 levels) was then used to evaluate the impact of bearing surface selection on outcomes, after adjusting for patient-, hospital-, and surgeon-related factors.

Results

For primary THA patients treated with C-PE bearings and COC bearings, there was significantly reduced risk of infection relative to M-PE bearings (C-PE Hazard Ratio, HR: 0.86, p=0.001; COC Hazard Ratio, HR: 0.74, p=0.01). For the C-PE cohort, we also observed reduced risk of 90-day readmission (HR: 0.94, p<0.001); dislocation (HR: 0.81, p<0.001); and mortality (HR: 0.92, p<0.001). There was no significant difference in risk of revision for either the C-PE or COC bearing cohorts when compared with M-PE. For the COC cohort, there was no significant difference in readmission, dislocation, or mortality risk.

Conclusions

The results indicate that, after adjusting for selection bias and various confounding patient-, surgeon-, and hospital-related factors, Medicare patients treated with primary THA with ceramic bearings exhibit lower risk of infection than those treated with M-PE bearings. In addition, C-PE bearings were associated with lower risk of dislocation and mortality. As in previous registry studies, we found that ceramic bearings have similar revision risk as M-PE bearings in primary THA at between 8 and 9 years of follow-up. The findings of this study support further research into the long-term association between ceramic bearings in primary THA and clinical outcomes.


*Email: