header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Research

18F-FLUORIDE PET/CT AS AN EARLY PREDICTOR OF BONY FUSION AFTER POSTERIOR LUMBAR INTERBODY FUSION

European Orthopaedic Research Society (EORS) 2016, 24th Annual Meeting, 14–16 September 2016. Part 1.



Abstract

The clinical success of posterior lumbar interbody fusion (PLIF) may be limited by pseudarthrosis, defined as the absence of solid fusion 1 year after surgery. Currently, CT is used to diagnose pseudarthrosis but is not able to be conclusive earlier than 1 year after surgery. No non-invasive technique is available to reliably assess bone graft incorporation in the early phase after PLIF.

Positron Emission Tomography (PET) is a nuclear imaging modality that is able to identify changes at the cellular and molecular level in an early stage, well before manifestation of anatomical changes. PET/CT with the bone seeking tracer 18F-fluoride allows localization and quantification of bone metabolism.

This study investigates whether an 18F-fluoride PET/CT scan early after PLIF is able to predict the fusion status at 1 year postoperative on CT.

Twenty patients after PLIF were enrolled after written informed consent. At 6 weeks and at 1 year after PLIF, intravenous injection of 18F-fluoride was followed by a static scan at 60 minutes (Philips, Gemini TF PET/CT). Processing of images resulted in a bone metabolism parameter i.e. standardized uptake value (SUV). This parameter was determined for 3 regions of interest (ROIs): the intervertebral disc space (IDS) and the upper and lower endplate (UE and LE, respectively) of the operated segment.

Interbody fusion was scored on a diagnostic CT scan made 1 year postoperatively and was defined as the amount of complete bony bridges between vertebrae, i.e 0, 1 or 2. Based on these scores, patients were divided in either the pseudarthrosis group (score 0) or the fusion group (scores 1 and 2). Differences between groups were analyzed using the independent samples Mann-Whitney U-test.

Ten patients were classified as pseudarthrosis (0 bridges: n=10) and 10 patients as fused (1 bridge: n=5, 2 bridges: n=5).

Patients in the pseudarthrosis group showed significantly lower bone metabolism values in the IDS on the 6 weeks PET/CT scan compared to patients in the fusion group (SUVIDS,6w13.3±5.62 for pseudarthrosis and 22.6±6.42 for the fusion group, p=0.003), whereas values at the endplates were similar (SUVUE,6w20.3±5.85 for pseudarthrosis and 21.6±4.24 for the fusion group, p=0.282). Furthermore, only in the pseudarthrosis group, bone metabolism in the IDS was significantly lower than at the endplates (p=0.006). In the fusion group, bone metabolism in the IDS and at the endplates was similar (p=0.470).

The PET/CT scan at 1 year postoperative showed that in the pseudarthrosis group, bone metabolism of the IDS remained lower compared to the endplates (SUVIDS,1y13.2±4.37, SUVUE,1y16.4±5.33, p=0.004), while in the fusion group, IDS and endplate bone metabolism was similar (SUVIDS,1y13.6±2.91, SUVUE,1y14.4±3.14, p=0.397).

This study shows that low bone metabolism values in the IDS of the operated segment as seen on 18F-fluoride PET/CT 6 weeks after PLIF, is related to development of pseudarthrosis 1 year postoperatively. These results suggest that 18F-fluoride PET/CT might be an early diagnostic tool to identify patients prone to develop pseudarthrosis after PLIF.