header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

FEMORAL BOWING IS MAIN DETERMINANT OF THE PROPER ALIGNMENT TO RESTORE MECHANICAL AXIS IN TOTAL KNEE ARTHROPLASTY

The International Society for Technology in Arthroplasty (ISTA), 28th Annual Congress, 2015. PART 3.



Abstract

Introduction

The success of knee replacement surgery depends, in part, on restoration of the correct alignment of the leg with respect to the load-bearing vector passing from the hip to the ankle (the mechanical axis). Conventional thinking is that the correct angle of resection of the distal femur (Valgus Cut Angle, VCA) depends on femoral length or femoral offset, though femoral bowing, in addition to length and medial offset, may also have a significant influence on the VCA. We hypothesized that femoral bowing has a strong effect on the VCA necessary to restore physiologic alignment after arthroplasty or osteotomy.

Methods

A total of 102 long-leg radiographs were obtained from patients scheduled for primary total knee arthroplasty. The patients on average were 41% male 59% female, 67.9 ± 11.1 years, 67.0 ± 4.7 in, 192 ± 43 lbs, and had a BMI of 29.7 ± 4.8. All radiographs were prepared with the feet placed in identical rotation and the patellae pointing forward, and were excluded if there was evidence of malrotation, as defined by (i) a difference in the medial head offsets of the right and left femur of >3mm, (ii) a difference in the width of the tibiofibular syndesmoses, or (iii) a difference in the rotation of one foot compared to the other.

The following anatomic variables were measured on each radiograph: (i) the neck shaft angle (NSA) of the femur, (ii) the length of the femur, (iii) the length of the femoral shaft, (iv) the medial head offset, (v) the medial-lateral bow of the distal femur, (vi) the hip- knee axis angle, (vii) the mechanical axis deviation of the extremity at the knee, (viii) the medio-lateral bow of the tibia, and (ix) the valgus cut angle required to restore the mechanical axis to the center of the knee during surgery (VCA). Bivariate plots were constructed using the measurements thought to influence the VCA: femoral bowing, femoral offset, and length of femur. Multivariate regression was then used to find the variable that had the strongest effect on the VCA.

Results

The bivariate plot of offset and VCA yielded an R2 of 0.02544 (p = 0.11) was not statistically significant. However, the bivariate plot of femoral length and VCA yielded an R2 of 0.1294 (p = 0.0002) showing significant correlation. Lastly, the bivariate plot of femoral bowing and VCA yielded an R2 of 0.59136 (p < 0.00001) demonstrating significant correlation (Figure 3). Multivariate analysis revealed that femoral bowing was the best predictor of VCA: VCA = 5.46–0.363 femoral bowing (°) + 0.106 Femoral offset (mm) − 0.010 femoral length (mm).

Discussion

While clinicians performing knee replacements typically do not consider femoral bowing when selecting the valgus angle appropriate for each patient, our findings demonstrate that femoral bowing has a potent effect on VCA. The multivariate regression indicated that femoral bowing had the highest effect on VCA followed by offset and femoral length. These findings suggest that surgeons should consider measuring long alignment radiographs before performing a total knee arthroplasty.


*Email: