General Orthopaedics

20-Year Survival of Cemented Versus Cementless Total Hip Arthroplasty for 60-Year Old or Younger Patients With Hip Dysplasia

International Society for Technology in Arthroplasty (ISTA) 2012 Annual Congress



Abstract

Although there are several reports of excellent long-term survival after cemented total hip arthroplasty (THA), cemented acetabular components are prone to become loose when compared with femoral components. On the other hand, the survival of cementless acetabular components has been reported to be equal or better than cemented ones and the use of cementless acetabular components is increasing. However, most of the reports on survival after THA are for patients with primary hip osteoarthritis (OA) and there is no report of 20-year survival of cementless THA for patients with hip dysplasia. It is supposed to be more difficult to fix cementless acetabular components for OA secondary to hip dysplasia than primary OA. The purposes of this study were to review retrospectively the 20-year survival of cemented and cementless THA for hip dysplasia and to compare the effect of fixation methods on the long-term survival for patients with hip dysplasia. We retrospectively reviewed all patients with OA secondary to hip dysplasia treated with a cemented Bioceram hip system between 1981 and 1987, and a cementless cancellous metal Lübeck hip system between 1987 and 1991. We excluded patients aged more than 60 years, males, and Crowe 4 hips. The studied subjects were 70 hips of cemented THA (Group-C) and 57 hips of cementless THA (Group-UC). Both hip implants had a 28-mm alumina head on polyethylene articulation. The mean age at operation was 50.5 years (range, 36–60 years) in Group-C and 50.0 years (range, 29–60 years) in Group-UC. The mean BMI was 23.2 kg/m2 in Group-C (range, 17.3–29.3 kg/m2) and 22.9 kg/m2 in Group-UC (range, 18.8–28.0 kg/m2). There were no significant differences in age and BMI between the two groups. The average follow-up period was 18.0 years in Group-C and 18.4 years in Group-UC. In Group-C, revision was performed in 33 hips due to aseptic cup loosening (30 hips), stem loosening (one hip), and loosening of both components (two hips). In Group-UC, revision was performed in 10 hips due to stem fracture secondary to distal fixation (4 hips), cup loosening (three hips), polyethylene breakage (two hips), and extensive osteolysis around the stem (one hip). The survival at 20 years regarding any revision as the endpoint was 51% in Group-C and 84% in Group-UC. This difference was significant using Log-rank test (P=0.006). The cup survival at 20 years was 54% in Group-C and 92% in Group-UC. This difference was also significant (P = 0.0003). The stem survival at 20 years was 95% in Group-C and 92% in Group-UC. This difference was not significant (P = 0.4826). Cementless THA showed a higher survival rate at 20 years for hip dysplasia than cemented THA because of the excellent survival of the acetabular component without cement. We conclude that cementless THA with the cancellous metal Lübeck hip system led to better longevity at 20 years than cemented THA with the Bioceram for patients with OA secondary to hip dysplasia.