header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

5.4 TO 12.9 YEAR RESULTS OF MENISCAL REPAIR USING AN ARTHROSCOPIC ASSISTED INSIDE-OUT SUTURE TECHNIQUE.



Abstract

This study reports our long-term results of arthroscopically assisted meniscal suture using an inside-out technique.

Between January 1990 and July 1997, 112 patients underwent 121 meniscal repairs in 112 knees. The average follow-up is 8.7 years (range 5.4 to 12.9 years). Repairs consisted of interrupted sutures using 2.0 PDS. Sutures were placed arthroscopically using a suture shuttle system and tied behind the capsule after making a small postero-medial or posterolateral incision. The meniscus and bed was prepared using a Rasp or hand-held instruments. Fibrin clot techniques were not used. 79% of patients had associated ACL reconstruction in addition to meniscal suture. All surgery was carried out by our senior author (PTM). Rehabilitation involved non-weight-bearing in an extension splint for 3 weeks and partial weight-bearing for a further 3 weeks followed by a progressive rehabilitation programme.

The average age at surgery was 23.9 years (range 12.2 to 57.7 years). The average time from injury to surgery was 13.5 months (range 0 to 60 months). There were 74 males and 38 females. 51% of patients were professional or semi-professional athletes. Repair involved 79 medial menisci, 42 lateral menisci. The average number of sutures used was 3.8 (range 1 to 12). Operative findings and procedure were entered prospectively into a database. Patients were assessed clinically until recovery and long-term follow-up consisted of a detailed postal questionnaire.

The average Lysholm scores were 86.4, with 59% excellent, 16% good, 17% fair and 8% poor. IKDC subjective scores averaged 82.0, with 40% excellent, 21% good, 27% fair and 12% poor. Confirmed failure of meniscal repair (as indicated by MRI or re-arthros-copy) has been identified in 11.8% of patients. A further 10.8% have a probable failure based on a recurrence of mechanical symptoms. Of the failures 73% were professional or semi-professional sportsman. Their average return to sport after surgery was 9.5 months (range 3 to 18 months). Failure was reported at an average of 29.3 months after surgery (range 0 to 84 months).

With an aggressive approach towards meniscal preservation we have achieved a success rate of 77.4% at an average follow-up of 8.7 years.

The majority of these tears are vertical posterior horn or large bucket handle and associated with an ACL reconstruction. The majority of patients are young and involved in a high level of sporting activity.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom