header advert
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 892 - 898
1 Nov 1996
Bulstra SK Geesink RGT Bakker D Bulstra TH Bouwmeester SJM van der Linden AJ

We have investigated the use of a conically-shaped cement plug made of Polyactive (PA), a biodegradable copolymer. The flexibility and hydrogel properties were thought to facilitate occlusion of the femoral canal even when it was oval or irregular in shape. The function of the plug was first compared with that of the Thackray polyethylene model in 16 artificial plastic femora.

The maximum intramedullary pressure achieved during cementing was ten times higher with the biodegradable model. Migration or leakage of cement did not occur when the diameter of the femoral canal was equal to or smaller than the diameter of the plug. We also showed that the biodegradable properties of this implant were such that it did not require removal during revision.

The new plug was tested in a pilot clinical trial. At two years only two out of 21 patients had evidence of migration or leakage of cement, probably due to a mismatch in the size of plug and femoral canal. There were no local changes in the femur.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 128 - 132
1 Jan 1996
Verhaar JAN Walenkamp GHIM van Mameren H Kester ADM van der Linden AJ

We performed a prospective, randomised trial on 106 patients to compare the effects of local corticosteroid injections with physiotherapy as advocated by Cyriax in the treatment of tennis elbow. The main outcome measures were the severity of pain, pain provoked by resisted dorsiflexion of the wrist, and patient satisfaction.

At six weeks 22 of 53 patients in the injection group were free from pain compared with only three in the physiotherapy group. In the corticosteroid-treated group 26 patients had no pain on resisted dorsiflexion of the wrist compared with only three in the physiotherapy group. Thirty-five patients who had injections and 14 who had physiotherapy were satisfied with the outcome of treatment at six weeks. At the final assessment there were 18 excellent and 18 good results in the corticosteroid group and one excellent and 12 good results in the physiotherapy group. There was a significant increase in grip strength in both groups but those with injections had a significantly better result.

After one year there were no significant differences between the two groups. Half of the patients, however, had received only the initial treatment, 20% had had combined therapy and 30% had had surgery.

We conclude that at six weeks, treatment with corticosteroid injections was more effective than Cyriax physiotherapy and we recommend it because of its rapid action, reduction of pain and absence of side-effects.