header advert
Results 1 - 5 of 5
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 461 - 466
1 Apr 2007
Tsuboi M Hasegawa Y Suzuki S Wingstrand H Thorngren K

We studied prospectively the change over ten years in mortality, walking ability and place of residence after a hip fracture in 753 patients in Japan. We compared the deaths observed in these patients with those expected in the general population, matched for age, gender and calender year at the time of fracture. The survival rate decreased dramatically for two years after the event and the mortality risk remained higher for ten years. This risk was approximately double that of the general population, even at ten years after fracture. The risk was higher, and remained so for longer, in younger rather than in older patients.

The proportion of patients who were able to walk outdoors alone, with or without an assistive device, was 68% (514) before fracture. This decreased to 56% (340) by one year after and remained stable at approximately 63% (125) until ten years. The proportion of patients living in their own home was 84% (629) before fracture, 81% (491) one year later, and then remained stable at approximately 86% (171) until ten years after the event.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 3 | Pages 377 - 381
1 May 1998
Ilchmann T Markovic L Joshi A Hardinge K Murphy J Wingstrand H

We analysed in-vivo migration and wear over a long period of all-polyethylene acetabular cups which had not been affected by mechanical loosening. The selection criteria of regular radiological follow-up, good clinical outcome (Charnley score of 5 or 6), continued walking without crutches and no radiological signs of loosening of the acetabular cups were fulfilled by 25 Charnley total hip arthroplasties.

Mean migration, measured by the Nunn method, was 0.6 mm in the medial and 0.2 mm in the cranial direction. The mean yearly rate of wear was 0.05 mm and 0.04 mm, with six and two cups having no detectable wear, as measured by the Livermore and Charnley-Cupic methods, respectively. The maximal detected wear was 3.7 mm. There were no changes in the rate of wear with time. Computerised Ein Bild Röntgen Analyse (single-image radiological analysis) measurements of 20 hips indicated plastic deformation of the cups.

We conclude that long-term successful cups do not migrate and have a very low rate of wear which was not affected by ageing of the polyethylene. There was no evidence that polyethylene wear alone caused mechanical loosening of the cup but high rates of wear seem to have an adverse prognostic value in terms of the long-term survival of the prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 379 - 382
1 May 1990
Egund N Nilsson L Wingstrand H Stromqvist B Pettersson H

Computed tomography was performed on 40 patients with recent hip trauma. Radiographs of 25 showed a fracture of the femoral neck with slight displacement; 24 of these had intra-articular fluid and 20 had a lipohaemarthrosis on the CT scan. In 15 patients, radiographs at the time of admission were normal but suspicion of fracture remained. A fracture was later verified in five patients, four of whom had lipohaemarthrosis on admission. In the remaining 10 patients no fracture could be detected; only one patient had a hip joint effusion but no free fat. Thus all 24 patients with lipohaemarthrosis had an intracapsular fracture of the hip. We suggest CT for patients with hip trauma and negative radiographs. The presence of a lipohaemarthrosis of the hip strongly suggests an intra-articular fracture of either the femoral neck or the acetabulum.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 2 | Pages 192 - 194
1 Mar 1988
Stromqvist B Nilsson L Egund N Thorngren K Wingstrand H

We studied intracapsular pressure in 50 patients with Garden Grade I and II subcapital fractures. Before operation pressures varied from zero to 320 mmHg, 16 patients having an intracapsular pressure of over 80 mmHg. The pressure was increased considerably by medial rotation and decreased by lateral rotation and especially by semi-flexion. From zero to 36 ml of blood was aspirated; the amount did not correlate with the intracapsular pressure. Of 25 patients who were also examined by scintimetry, 13 had reduced uptake at the femoral head before aspiration, and nine of these showed a marked increase in uptake after aspiration. Intracapsular tamponade of the hip may be one reason for the occasional occurrence of segmental collapse of the femoral head after subcapital fracture with minor displacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 254 - 256
1 Mar 1987
Wingstrand H Egund N Forsberg L

Sonography was successfully used to diagnose an effusion in the hips of three adults with septic arthritis and four with aseptic synovitis. The effusions were confirmed by aspiration. All the patients had markedly increased intracapsular pressure which, in the extended position, exceeded the systolic blood pressure and could well compromise the blood supply to the head of femur. Aspiration reduced pain and intracapsular pressure, as did flexion of the hip to 45 degrees.