header advert
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1539 - 1539
1 Nov 2008
Thomas N


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 1 | Pages 1 - 1
1 Jan 2004
Thomas N Hamblen D


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 4 | Pages 747 - 748
1 Jul 1999
Thomas N


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 312 - 316
1 Mar 1987
Thomas N Turner I Jones C

Four types of prosthetic replacement for the anterior cruciate ligament (carbon fibre, carbon fibre and Dacron composite, Dacron alone and bovine xenograft) were assessed at three, six and 12 months after implantation in the knees of New Zealand white rabbits. The synovium and both intra-articular and intra-osseous portions of the ligaments were examined macroscopically, by light microscopy and by scanning electron microscopy. All the knees showed mild synovitis, and there was no significant growth into the intra-articular part of any ligament. Carbon fibre and xenograft did not appear to be suitable materials in this animal model. The composite ligament showed short-term ingrowth of fibrous tissue only into the periphery of the sheath in its intra-osseous portion, whereas the Dacron ligament showed progressive fibrous tissue ingrowth with some bony incorporation of its outer fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 173 - 177
1 Mar 1986
Ransford A Crockard H Pozo J Thomas N Nelson I

Rigid posterior fixation of the skull to the third, fourth and fifth cervical vertebrae was achieved in three patients who, as a result of operation, had gross instability of the craniocervical junction. An anatomically contoured steel loop was secured to the occiput via small burr holes and to the vertebrae by sublaminar wiring. This technique has the advantage over bone grafting, either alone or with cement, in that it affords rigid stabilisation, allows early mobilisation and may contribute to eventual bony fusion.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 301 - 304
1 Mar 1986
Simpson D Thomas N Aichroth P

We reviewed 230 patients an average of 34 months after they had undergone partial or total meniscectomy by surgeons of different experience in a busy unit. Open and arthroscopic meniscectomies were compared. Arthroscopic partial meniscectomy resulted in a significant reduction of inpatient stay and earlier return to work and sport. Analysis of the type of meniscal damage showed that arthroscopic removal of "bucket handles" achieved better results than open techniques. Comparatively poor results were found for lateral meniscectomy.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 4 | Pages 572 - 575
1 Aug 1985
Thomas N Jackson A Aichroth P

The clinical and radiological features of 12 knees (10 patients) with congenital absence of the anterior cruciate ligament are presented. The high frequency of this condition in association with other more easily recognised congenital abnormalities of the knee is discussed. It is concluded that congenital absence of the anterior cruciate ligament is more common than generally suspected and is associated with other developmental abnormalities of both bone and soft tissue in the lower limb, particularly around the knee joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 134 - 139
1 Mar 1983
Jones S Edgar M Ransford A Thomas N

An electrophysiological system for monitoring the spinal cord during operations for scoliosis is described. During the development of the technique the recording of cortical somatosensory evoked potentials from the scalp and spinal somatosensory evoked potentials from the laminae or spines was superseded by the positioning of recording electrodes in the epidural space cephalad to the area to be fused. All recordings were made in response to stimulation of the posterior tibial nerve at the knee. Results in 138 patients are presented and the findings in three patients who exhibited neurological deficits after operation are described. It is concluded that spinal somatosensory evoked potentials are sensitive to minor spinal cord impairment, possible due to ischaemia, and that these changes may be reversed when the cause is quickly remedied. The monitoring system interferes minimally with anaesthetic and surgical procedures and is now performed as a routine.