Vol. 99-B, Issue 10 | Pages 1290 - 1297
1 Oct 2017
Devane PA Horne JG Foley G Stanley J

Aims

This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient’s bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA).

Materials and Methods

Models of the patient’s acetabular and femoral component obtained from the manufacturer and models of the patient’s pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 936 - 936
1 Sep 1999
Stanley J


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 691 - 695
1 Sep 1995
Dent C Hoy G Stanley J

We reviewed 25 patients with rheumatoid arthritis who had failure of 26 primary total elbow arthroplasties causing pain and loss of function. Most revision cases required special custom implants to treat varying bone loss and soft-tissue disruption. Assessment showed satisfactory functional results in the patients treated by revision at a mean follow-up period of 35 months. Our review suggests that revision surgery produces short- to medium-term painfree function, and is the treatment of choice for a failed total elbow arthroplasty in the absence of infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 691 - 700
1 Sep 1994
Stanley J Trail I


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 923 - 927
1 Nov 1992
Sanderson P Morris M Stanley J Fahmy N

We studied prospectively the relationship between serum lipids and Dupuytren's disease of the hand in 85 patients, 65 men and 20 women. The Dupuytren patients had significantly higher fasting serum cholesterol and triglyceride levels than did the controls (p < 0.001). The raised levels of serum lipids appeared to be associated with the pathogenesis of Dupuytren's disease, and this may help to explain the high incidence of Dupuytren's disease in alcoholic, diabetic and epileptic patients, since these conditions are also associated with raised serum lipid levels.


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 4 | Pages 401 - 409
1 Nov 1979
Stanley J Owen R Koff S

A review of seventy-one children with sacral anomalies is presented. The aetiology is discussed and a classification of sacral anomalies is suggested, with three groups of patients: agenetic, dysgenetic and dysraphic. The clinical presentation of each group is discussed and the high incidence of congenital visceral and skeletal abnormalities is indicated in the dysgenetic group. The need for constant urological assessment is emphasised, particularly in the agenetic and dysraphic children.