header advert
Results 1 - 3 of 3
Results per page:
Bone & Joint Research
Vol. 2, Issue 5 | Pages 79 - 83
1 May 2013
Goffin JM Pankaj P Simpson AHRW Seil R Gerich TG

Objectives

Because of the contradictory body of evidence related to the potential benefits of helical blades in trochanteric fracture fixation, we studied the effect of bone compaction resulting from the insertion of a proximal femoral nail anti-rotation (PFNA).

Methods

We developed a subject-specific computational model of a trochanteric fracture (31-A2 in the AO classification) with lack of medial support and varied the bone density to account for variability in bone properties among hip fracture patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 832 - 833
1 Aug 2001
Gödde S Rupp S Dienst M Seil R Kohn D

The Fulkerson osteotomy has proved to be a reliable treatment for subluxation of the patella due to malalignment. Aggressive rehabilitation in the early postoperative period is unwise since the proximal tibia is weakened by the oblique osteotomy. Early weight-bearing and unrestricted activity have caused fractures in a few patients. Even late in the postoperative period the osteotomy may adversely influence the biomechanical properties of the proximal tibia.

We describe two athletes who sustained a fracture of the proximal tibia, during recreational activities, six months after a Fulkerson osteotomy. Both had been bearing full weight for about ten weeks without complaint. Bony healing of the osteotomy had been demonstrated on plain radiographs at ten and at 12 weeks. After a Fulkerson osteotomy, jogging and activities which impose considerable impact force should be discouraged for at least nine to 12 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1059 - 1064
1 Sep 2000
Rupp S Seil R Kohn D Müller B

Our aim was to analyse the effect of avascularity on the morphology and mechanical properties (tensile strength, viscoelasticity) of human bone-patellar-tendon-bone (BPTB) grafts in vitro. These were harvested at postmortem and stored submerged in denaturated human plasma at a constant pH, pO2, pCO2, temperature and humidity under sterile conditions. Mechanical testing was performed two and four weeks after removal of the graft. The mean ultimate strength was 1085.7 ± 255.8 N (control), 1009.0 ± 314.9 N (two weeks cultured) and 1076.8 ± 414.8 N (four weeks cultured). There was no significant difference in linear stiffness or deformation to failure between the groups. There was a difference in viscoelasticity between the control group and the avascular grafts and the latter had significant lower peak load-to-load ratios after 15 minutes compared with the control group. After two and four weeks the graft contained viable fibroblasts. There was regular cellularity in the superficial layers and decreased cellularity in the midportion. The structure of the collagen including the crimp pattern appeared to be normal in polarised light.

We conclude that avascularity does not significantly affect ultimate failure loads or stiffness of BPTB grafts. Slight changes in viscoelasticity were induced, but the significance of the increased stress relaxation is not fully understood.