header advert
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 491 - 494
1 May 1994
Jennings A Seedhom B

There are various methods of measuring proprioception at the knee. Beard et al (1993) have described a delay in reflex hamstring contraction in anterior cruciate deficient knees. We have repeated their experiment and were unable to detect any significant difference in reflex hamstring contraction between the injured and uninjured legs. We discuss possible neurophysiological and biomechanical causes for the conflicting results and conclude that this method may not be a valid measure of proprioception.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 2 | Pages 200 - 203
1 Mar 1994
Fujikawa K Ohtani T Matsumoto H Seedhom B

We describe a new method for the reconstruction of ruptures of the patellar ligament or the quadriceps tendon, using the flexible open-weave polyester Leeds-Keio prosthetic ligament. Of 25 operations performed since 1985, we were able to review 18 patients (19 knees) with a mean follow-up of 3.5 years (3 to 6.5). No patient had required immobilisation of the knee after operation and the average period to return to normal activities without a walking aid was 10.5 weeks. The average range of motion was 146 degrees, and four patients could squat fully in the Japanese style. There was an extension lag (< 10 degrees) in only four patients; eight patients had some patellar crepitus which was mildly painful in three. There were no cases of infection, persistent joint effusion or rerupture of the extensor apparatus.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 566 - 570
1 Aug 1989
Fujikawa K Iseki F Seedhom B

The healing of anterior cruciate ligaments reconstructed with the Leeds-Keio artificial ligament was observed by arthroscopy in 42 knees and biopsy in 19 knees at intervals from 3 to 24 months after implantation. By three months the implant was covered with immature new tissue, and a dense vascular network crossed its surface. At 12 months a new ligament had developed and matured, looking like the natural one in most cases. Histology at this stage showed abundant collagenous fibres running parallel and longitudinally, while the synovial membrane showed no more than very slight inflammatory changes. By 18 to 24 months, the new ligament often had the arthroscopic appearance of a normal anterior cruciate ligament. These results suggest that this scaffold type of artificial ligament is effective for cruciate reconstruction, giving satisfactory healing without significant complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 2 | Pages 255 - 260
1 Mar 1985
Nakamura N Ellis M Seedhom B

The effects of advancement of the tibial tuberosity by inserting bony wedges was studied on cadaveric specimens of the knee. The geometry, the contact areas and the forces acting on the patellofemoral joint were investigated, and the forces acting on the tibiofemoral compartment were calculated. A 1 cm advancement was found to be optimal in reducing the high patellofemoral joint forces occurring at 90 degrees and 110 degrees of flexion, whilst causing least reduction of the contact areas; the stresses on the joint were reduced significantly. Advancement by 2 cm and by 3 cm drastically reduced the congruity and the size of the contact area. It was also shown that 2 cm and 3 cm advancement caused an increase in forces at the patellofemoral joint and also in the tibiofemoral joint in a direction tangential to the articular surfaces.