header advert
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 382 - 385
1 Mar 2006
Schindler OS Spencer RF Smith MD

The aim of this study was to re-assess whether the use of a ‘one-knife technique’ can be considered as safe as the alternative practice of using separate skin and inside knives for elective orthopaedic surgery. A total of 609 knife blades from 203 elective orthopaedic operations, with equal numbers of skin, inside and control blades, were cultured using direct and enrichment media. We found 31 skin blades (15.3%), 22 inside blades (10.8%), and 13 control blades (6.4%) gave bacterial growth.

Of the 31 contaminated skin blades only three (9.7%) had growth of the same organism as found on the corresponding inside blade. It is not known whether contamination of deeper layers in the remaining 90% was prevented by changing the knife after the skin incision. The organisms cultured were predominantly coagulase-negative staphylococci and proprionibacterium species; both are known to be the major culprits in peri-prosthetic infection. Our study suggests that the use of separate skin and inside knives should be maintained as good medical practice, since the cost of a single deep infection in human and financial terms can be considerable.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 927 - 937
1 Nov 1997
Schindler OS Cannon SR Briggs TWR Blunn GW

The use of extendible distal femoral replacements is a relatively new treatment alternative for malignant bone tumours in growing individuals. Although their appearance was widely appreciated, questions about functional practicality and longevity remain unclear. With longer follow-up, advantages of immediate functional restoration and beneficial psychological aspects seem to be overshadowed by an increase in complications such as aseptic loosening, infection or prosthetic failure.

We have reviewed 18 children with such tumours who were treated between 1983 and 1990 by custom-made Stanmore extendible distal femoral replacements. Four died from metastatic disease within 2.5 years of operation and two required amputation for local recurrence or chronic infection.

The remaining 12 patients were followed for a mean of 8.7 years (6 to 13.2). A mean total lengthening of 5.2 cm was achieved, requiring, on average, 4.3 operations. Using the Musculoskeletal Tumor Society rating score the functional result at review was, on average, 77% of the expected normal function, with seven patients achieving ≥ 80%. Revision of the prosthesis was required in ten patients, in six for aseptic loosening, at a mean of 6.2 years after the initial procedure.