header advert
Results 1 - 8 of 8
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 741 - 746
1 Jun 2016
Hagio T Naito M Nakamura Y Muraoka K

Aims

Acetabular dysplasia is frequently associated with intra-articular pathology such as labral tears, but whether labral tears should be treated at the time of periacetabular osteotomy (PAO) remains controversial. The purpose of this study was to compare the clinical outcomes and radiographic corrections of PAO for acetabular dysplasia between patients with and without labral tears pre-operatively.

Patients and Methods

We retrospectively reviewed 70 hips in 67 patients with acetabular dysplasia who underwent PAO. Of 47 hips (45 patients) with labral tears pre-operatively, 27 (25 patients) underwent PAO alone, and were classified as the labral tear alone (LT) group, and 20 (20 patients) underwent combined PAO and osteochondroplasty, and were classified as the labral tear osteochondroplasty (LTO) group. The non-labral tear (NLT) group included 23 hips in 22 patients.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 597 - 603
1 May 2014
Nomura T Naito M Nakamura Y Ida T Kuroda D Kobayashi T Sakamoto T Seo H

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°).

Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001).

This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs.

Cite this article: Bone Joint J 2014; 96-B:597–603.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1438 - 1442
1 Nov 2009
Maeyama A Naito M Moriyama S Yoshimura I

We compared the dynamic instability of 25 dysplastic hips in 25 patients using triaxial accelerometry before and one year after periacetabular osteotomy. We also evaluated the hips clinically using the Harris hip score and assessed acetabular orientation by radiography before surgery and after one year. The mean overall magnitude of acceleration was significantly reduced from 2.30 m/s2 (sd 0.57) before operation to 1.55 m/s2 (sd 0.31) afterwards. The mean Harris hip score improved from 78.08 (47 to 96) to 95.36 points (88 to 100). The radiographic parameters all showed significant improvements.

This study suggests that periacetabular osteotomy provides pain relief, improves acetabular cover and reduces the dynamic instability in patients with dysplastic hips.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1150 - 1156
1 Aug 2005
Hayashi K Fotovati A Ali SA Oda K Oida H Naito M

The reduced stability of hydroxyapatite (HA)-coated implants in osteopenic conditions is considered to be a major problem. We therefore developed a model of a boosted cementless implantation in osteopenic rats.

Twelve-week-old rats were either ovariectomised (OVX) or sham-operated (SO), and after 24 weeks plain or HA-coated implants were inserted. They were treated with either a prostaglandin EP4 receptor agonist (ONO-4819) or saline for one month.

The EP4 agonist considerably improved the osteoporosis in the OVX group. Ultrastructural analysis and mechanical testing showed an improvement in the implant-bone attachment in the HA-coated implants, which was further enhanced by the EP4 agonist. Although the stability of the HA-coated implants in the saline-treated OVX rats was less than in the SO normal rats, the administration of the EP4 agonist significantly compensated for this shortage. Our results showed that the osteogenic effect of the EP4 agonist augmented the osteoconductivity of HA and significantly improved the stability of the implant-bone attachment in the osteoporotic rat model.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 966 - 969
1 Sep 2004
Shiramizu K Naito M Shitama T Nakamura Y Shitama H

The existing methods of assessing limb lengthening during total hip arthroplasty (THA) are prone to error because the measurements are not parallel to the limb lengthening axis. In order to address this, we designed a caliper to estimate limb lengthening during THA and evaluated its accuracy compared with our previous device, the straight caliper. Limb lengths were measured in 100 patients. The L-shaped caliper was used in 50 cases and the straight caliper in 50. The correlation between intra-operative and post-operative radiographic measurements was significantly improved using the L-shaped device (p < 0.0001, r = 0.934). This method was extremely accurate in predicting changes in limb length due to surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 6 | Pages 922 - 925
1 Nov 1994
Naito M Ogata K Shiota E Oyama M

We performed curettage and bone grafting of amyloid cysts of the femoral neck in five patients on long-term haemodialysis. All had had hip pain on weight-bearing. The duration of haemodialysis before the operation averaged 15 years and the average age of the patients was 53 years. All the large cystic lesions were located in the anterosuperior quadrant of the femoral neck. At operation, they were found to consist of fibrous tissue containing amyloid deposits. Postoperatively, all five patients had painless hips and the grafts had incorporated into the bone defects.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 428 - 431
1 May 1994
Naito M Ogata K Shiota E Nakamoto M Goya T

We retrospectively reviewed 17 hip arthroplasties in 15 patients having haemodialysis for chronic renal failure. The duration of haemodialysis before the operation averaged 8.6 years and the average age of the patients was 61 years. All patients were followed for more than two years (mean 4.6 years). Six arthroplasties in four patients had failed due to loosening, and one of these patients died from undiagnosed infection of both hips at 7.6 years after the operation. General skeletal abnormalities caused by maintenance haemodialysis may explain the high incidence of loosening and it is important to be aware of the danger of postoperative infection. The risk-to-benefit ratio of hip arthroplasty is high in patients on haemodialysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 5 | Pages 686 - 690
1 Sep 1992
Naito M Ogata K Nakamoto M Goya T Sugioka Y

We reviewed 29 patients who had developed destructive arthropathy of the spine during long-term haemodialysis. Their mean age when haemodialysis began was 43.8 years; at diagnosis they had been dialysed for an average of 8.6 years. In 26 patients, the lesions were between C4 and C7; in six they were between L4 and S1, three having lesions in both regions. Sixteen patients had had previous surgery for carpal tunnel syndrome. Spinal surgery was performed in nine patients with satisfactory results in only five. We demonstrated beta-2 microglobulin amyloid deposits in the discs and surrounding ligaments in all biopsied cases. The natural history and management of this condition are not yet clear.