Vol. 103-B, Issue 5 | Pages 872 - 880
1 May 2021
Young PS Macarico DT Silverwood RK Farhan-Alanie OM Mohammed A Periasamy K Nicol A Meek RMD

Aims

Uncemented metal acetabular components show good osseointegration, but material stiffness causes stress shielding and retroacetabular bone loss. Cemented monoblock polyethylene components load more physiologically; however, the cement bone interface can suffer fibrous encapsulation and loosening. It was hypothesized that an uncemented titanium-sintered monoblock polyethylene component may offer the optimum combination of osseointegration and anatomical loading.

Methods

A total of 38 patients were prospectively enrolled and received an uncemented monoblock polyethylene acetabular (pressfit) component. This single cohort was then retrospectively compared with previously reported randomized cohorts of cemented monoblock (cemented) and trabecular metal (trabecular) acetabular implants. The primary outcome measure was periprosthetic bone density using dual-energy x-ray absorptiometry over two years. Secondary outcomes included radiological and clinical analysis.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1220 - 1225
1 Sep 2015
Chen LB Wang H Tie K Mohammed A Qi YJ

A total of 22 patients with a tibial avulsion fracture involving the insertion of the posterior cruciate ligament (PCL) with grade II or III posterior laxity were reduced and fixed arthroscopically using routine anterior and double posteromedial portals. A double-strand Ethibond suture was inserted into the joint and wrapped around the PCL from anterior to posterior to secure the ligament above the avulsed bony fragment. Two tibial bone tunnels were created using the PCL reconstruction guide, aiming at the medial and lateral borders of the tibial bed. The ends of the suture were pulled out through the bone tunnels and tied over the tibial cortex between the openings of the tunnels to reduce and secure the bony fragment. Satisfactory reduction of the fracture was checked arthroscopically and radiographically.

The patients were followed-up for a mean of 24.5 months (19 to 28). Bone union occurred six weeks post-operatively. At final follow-up, all patients had a negative posterior drawer test and a full range of movement. KT-1000 arthrometer examination showed that the mean post-operative side-to-side difference improved from 10.9 mm (standard deviation (sd) 0.7) pre-operatively to 1.5 mm (sd 0.6) (p = 0.001). The mean Tegner and the International Knee Documentation Committee scores improved significantly (p = 0.001). The mean Lysholm score at final follow-up was 92.0 (85 to 96).

We conclude that this technique is convenient, reliable and minimally invasive and successfully restores the stability and function of the knee.

Cite this article: Bone Joint J 2015;97-B:1220–5.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 8 | Pages 1033 - 1044
1 Aug 2011
Periasamy K Watson WS Mohammed A Murray H Walker B Patil S Meek RMD

The ideal acetabular component is characterised by reliable, long-term fixation with physiological loading of bone and a low rate of wear. Trabecular metal is a porous construct of tantalum which promotes bony ingrowth, has a modulus of elasticity similar to that of cancellous bone, and should be an excellent material for fixation.

Between 2004 and 2006, 55 patients were randomised to receive either a cemented polyethylene or a monobloc trabecular metal acetabular component with a polyethylene articular surface. We measured the peri-prosthetic bone density around the acetabular components for up to two years using dual-energy x-ray absorptiometry.

We found evidence that the cemented acetabular component loaded the acetabular bone centromedially whereas the trabecular metal monobloc loaded the lateral rim and behaved like a hemispherical rigid metal component with regard to loading of the acetabular bone. We suspect that this was due to the peripheral titanium rim used for the mechanism of insertion.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 9 | Pages 1259 - 1261
1 Sep 2010
Gupta S Augustine A Horey L Meek RMD Hullin MG Mohammed A

The management of the patella during total knee replacement is controversial. In some studies the absence of patellar resurfacing results in residual anterior knee pain in over 10% of patients. One form of treatment which may be used in an endeavour to reduce this is circumferential patellar rim electrocautery. This is believed to partially denervate the patella. However, there is no evidence of the efficacy of this procedure, nor do we know if it results in harm.

A retrospective comparative cohort study was performed of 192 patients who had undergone a primary total knee replacement with the porous coated Low Contact Stress rotating platform prosthesis without patellar resurfacing between 2003 and 2007. In 98 patients circumferential electrocautery of the patellar rim was performed and in 94 patients it was not. The two groups were matched for gender and age. The general Oxford Knee Score and the more specific patellar score for anterior knee pain were used to assess patient outcomes a minimum of two years post-operatively.

No statistically significant differences were noted between the groups for either scoring system (p = 0.41 and p = 0.87, respectively). Electrocautery of the patella rim did not improve the outcome scores after primary total knee replacement in our patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 142 - 145
1 Jan 2010
Spencer SJ Holt G Clarke JV Mohammed A Leach WJ Roberts JLB

The humerus is a common site for skeletal metastases in the adult. Surgical stabilisation of such lesions is often necessary to relieve pain and restore function. These procedures are essentially palliative and should therefore provide effective relief from pain for the remainder of the patient’s life without the need for further surgical intervention.

We report a retrospective analysis of 35 patients (37 nails) with symptomatic metastases in the shaft of the humerus which were treated by locked, antegrade nailing. There were 27 true fractures (73.0%) and ten painful deposits (27.0%). Relief from pain was excellent in four (11.4%), good in 29 (82.9%) and fair in two (5.7%) on discharge. Function was improved in all but one patient. One case of palsy of the radial nerve was noted. The mean postoperative survival was 7.1 months (0.2 to 45.5) which emphasises the poor prognosis in this group of patients. There were no failures of fixation and no case in which further surgery was required.

Antegrade intramedullary nailing is an effective means of stabilising the humerus for the palliative treatment of metastases. It relieves pain and restores function to the upper limb with low attendant morbidity.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 64 - 66
1 Jan 1995
Mohammed A Rahamatalla A Wynne-Jones C