header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 9 | Pages 1232 - 1236
1 Sep 2017
Dahill M McArthur J Roberts GL Acharya MR Ward AJ Chesser TJS

Aims

The anterior pelvic internal fixator is increasingly used for the treatment of unstable, or displaced, injuries of the anterior pelvic ring. The evidence for its use, however, is limited. The aim of this paper is to describe the indications for its use, how it is applied and its complications.

Patients and Methods

We reviewed the case notes and radiographs of 50 patients treated with an anterior pelvic internal fixator between April 2010 and December 2015 at a major trauma centre in the United Kingdom. The median follow-up time was 38 months (interquartile range 24 to 51).


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 686 - 689
1 May 2016
Griffin XL Parsons N McArthur J Achten J Costa ML

Aims

The aim of this study was to inform a definitive trial which could determine the clinical effectiveness of the X-Bolt Dynamic Hip Plating System compared with the sliding hip screw for patients with complex pertrochanteric fragility fractures of the femur.

Patients and Methods

This was a single centre, participant blinded, randomised, standard-of-care controlled pilot trial. Patients aged 60 years and over with AO/ASIF A2 and A3 type femoral pertrochanteric fractures were eligible.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 210 - 213
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for independent patients with displaced intracapsular fractures of the proximal femur. The recognised alternatives are hemiarthroplasty and total hip replacement. At present there is no established standard of care, with both types of arthroplasty being used in many centres. The principal advantages of total hip replacement are a functional benefit over hemiarthroplasty and a reduced risk of revision surgery. The principal criticism is the increased risk of dislocation. We believe that an alternative acetabular component may reduce the risk of dislocation but still provide the functional benefit of total hip replacement in these patients. We therefore propose to investigate the dislocation risk of a dual-mobility acetabular component compared with standard polyethylene component in total hip replacement for independent patients with displaced intracapsular fractures of the proximal femur within the framework of the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:210–13.


Bone & Joint Research
Vol. 2, Issue 10 | Pages 206 - 209
1 Oct 2013
Griffin XL McArthur J Achten J Parsons N Costa ML

Fractures of the proximal femur are one of the greatest challenges facing the medical community, constituting a heavy socioeconomic burden worldwide. Controversy exists regarding the optimal treatment for patients with unstable trochanteric proximal femoral fractures. The recognised treatment alternatives are extramedullary fixation usually with a sliding hip screw and intramedullary fixation with a cephalomedullary nail. Current evidence suggests that best results and lowest complication rates occur using a sliding hip screw. Complications in these difficult fractures are relatively common regardless of type of treatment. We believe that a novel device, the X-Bolt dynamic plating system, may offer superior fixation over a sliding hip screw with lower reoperation risk and better function. We therefore propose to investigate the clinical effectiveness of the X-bolt dynamic plating system compared with standard sliding hip screw fixation within the framework of a the larger WHiTE (Warwick Hip Trauma Evaluation) Comprehensive Cohort Study.

Cite this article: Bone Joint Res 2013;2:206–9.