header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1506 - 1511
1 Dec 2019
Kim SH Yang SH Rhee S Lee KJ Kim HS Oh JH

Aims

The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during rotator cuff repair.

Patients and Methods

Transosseous-equivalent rotator cuff repair was performed in 73 patients. The patients were divided into two groups, in both of which two different medial-row anchors were used. In group 1, anchor A comprised 30% β-tricalcium phosphate (TCP) + 70% fast-absorbing poly lactic-co-glycolic acid copolymer (85% polylactic acid enantiomers + 15% polyglycolic acid) and anchor B comprised all-sutures. In group 2, anchor C comprised 23% micro β-TCP + 77% polylactic acid enantiomers and anchor D comprised PEEK polymer. There were 37 patients in group 1 and 36 patients in group 2. The presence and severity of fluid collection around anchors and healing of the rotator cuff were assessed using MRI scans, approximately one year postoperatively. The severity of the collection was graded as 0 (no perianchor fluid signal), 1 (minimal perianchor fluid), 2 (local collection of fluid), 3 (fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter), or 4 (fluid collection around the whole length of the anchor and of a diameter greater than twice the anchor diameter).


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 703 - 709
1 May 2016
Kim Y Kang HG Kim JH Kim S Lin PP Kim HS

Aims

The purpose of the study was to investigate whether closed intramedullary (IM) nailing with percutaneous cement augmentation is better than conventional closed nailing at relieving pain and suppressing tumours in patients with metastases of the femur and humerus.

Patients and Methods

A total of 43 patients (27 men, 16 women, mean age 63.7 years, standard deviation (sd) 12.2; 21 to 84) underwent closed IM nailing with cement augmentation for long bone metastases. A further 27 patients, who underwent conventional closed IM nailing, served as controls. Pain was assessed using a visual analogue scale (VAS) score pre-operatively (pre-operative VAS), one week post-operatively (immediate post-operative VAS), and at six weeks post-operatively (follow-up post-operative VAS). Progression of the tumour was evaluated in subgroups of patients using F-18-fludeoxyglucose (F-18-FDG) positron emission tomography (PET)/computed tomography (CT) and/or bone scintigraphy (BS), at a mean of 8.8 and 7.2 months post-operatively, respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1078 - 1082
1 Aug 2009
Kang HG Roh YW Kim HS

We have developed a hollow perforated cannulated screw. One or more of these was implanted percutaneously in 11 patients with an osteolytic metastasis in the femoral neck and multiple metastases elsewhere. They were supplemented by one or two additional standard 6.5 mm cannulated screws in nine patients. Polymethylmethacrylate bone cement was injected through the screw into the neck of the femur using small syringes, as in vertebroplasty. The mean amount of cement injected was 23.2 ml (17 to 30). Radiotherapy was started on the fourth post-operative day and chemotherapy, on average, was resumed a day later.

Good structural stability and satisfactory relief from pain were achieved in all the patients. This technique may be useful in the palliation of metastases in the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 333 - 336
1 Mar 2005
Bae DK Yoon KH Kim HS Song SJ

Between July 1986 and August 1996, we performed 32 total knee arthroplasties (TKA) on 32 patients with partially or completely ankylosed knees secondary to infection. Their mean age at surgery was 40 years (20 to 63) and the mean follow-up was ten years (5 to 13). The mean post-operative range of movement was 75.3° (30 to 115) in those with complete and 98.7° (60 to 130) in those with partial ankylosis. The mean Hospital for Special Surgery knee score increased from 57 to 86 points post-operatively. There were complications in four knees (12.5%), which included superficial infection (one), deep infection (one), supracondylar femoral fracture (one) and transient palsy of the common peroneal nerve (one). Although TKA in the ankylosed knee is technically demanding and has a considerable rate of complications, reasonable restoration of function can be obtained by careful selection of patients, meticulous surgical technique, and aggressive rehabilitation.