header advert
Results 1 - 6 of 6
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 821 - 824
1 Jun 2008
Board TN Rooney P Kay PR

In order to investigate the osteoinductive properties of allograft used in impaction grafting and the effect of strain during impaction on these properties, we designed an in vitro experiment to measure strain-related release of bone morphogenetic protein-7 (BMP-7) from fresh-frozen femoral head allograft. A total of 40 10 mm cubes of cancellous bone were cut from ten samples of fresh-frozen femoral head. The marrow was removed from the cubes and the baseline concentrations of BMP-7 were measured. Specimens from each femoral head were allocated to four groups and subjected to different compressive strains with a material testing machine, after which BMP-7 activity was reassessed. It was present in all groups. There was a linear increase of 102.1 pg/g (95% confidence interval 68.6 to 135.6) BMP-7 for each 10% increase in strain. At 80% strain the mean concentration of BMP-7 released (830.3 pg/g bone) was approximately four times that released at 20% strain. Activity of BMP-7 in fresh-frozen allograft has not previously been demonstrated. This study shows that the freezing and storage of femoral heads allows some maintenance of biological activity, and that impaction grafting provides a source of osteoinductive bone for remodelling.

We have shown that BMP-7 is released from fresh-frozen femoral head cancellous bone in proportion to the strain applied to the bone. This suggests that the impaction process itself may contribute to the biological process of remodelling and bony incorporation.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1141 - 1142
1 Sep 2006
Phillips SJ Chavan R Porter ML Kay PR Hodgkinson JP Purbach B Reddick AH Frayne JM

We carried out a retrospective case-control study in 80 patients who underwent a revision total hip replacement. Group A (40 patients) received tranexamic acid and intra-operative cell salvage. Group B (40 patients) was a matched control group and did not receive this management. Each group was divided into four subgroups: revision of both components, revision of both components with bone grafting, revision of the acetabular component with or without bone graft, and revision of the femoral component with or without bone graft.

In group A the total number of units transfused was 52, compared with 139 in group B, representing a reduction in blood usage of 62.5%. The mean amount of blood transfused from cell salvage in each group was 858 ml (113 to 2100), 477 ml (0 to 2680), 228 ml (75 to 315) and 464 ml (120 to 1125), respectively. There was a significant difference in the amount of blood returned between the groups (p < 0.0001).

In group A, 22 patients needed transfusion and in group B, 37 (p < 0.0001). A cost analysis calculation showed a total revenue saving of £70 000 and a potential saving throughout our facility of £318 288 per year.

Our results show that a significant reduction in blood transfusion can be made using combined cell salvage and tranexamic acid in revision surgery of the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 852 - 857
1 Jul 2006
Board TN Rooney P Kearney JN Kay PR


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 266 - 268
1 Mar 2004
Mohanty SS Kay PR

A retrospective review of MRSA screening showed that of a total of 8911 patients screened pre-operatively between May 1996 and February 2001, 83 (0.9%) had MRSA isolated from one source or another. During the same period, 115 (13.6%) of 844 positive tissue samples taken during surgery grew Staphylococcus aureus. Of these only 1 (0.01%) was reported to be methicillin-resistant (MRSA). However, a total of 366 (43.4%) isolates from tissue samples were reported as coagulase-negative staphylococci (C-NS). Of these, 312 samples were tested for methicillin sensitivity, of which 172 (55.1%) were found to be resistant.

Staphylococcus epidermidis is the most prevalent and persistent species found on most skin and mucous membranes, constituting 65% to 90% of all staphylococci. Most isolates in tissue samples were found to be methicillin-resistant coagulase-negative staphylococcus (55.1%). Hence, it may be appropriate to undertake screening for methicillin-resistant Staphylococcus epidermidis in addition to that for MRSA.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 776 - 776
1 Jul 2000
DAVIS N GAMBHIR AK KAY PR


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 5 | Pages 886 - 889
1 Sep 1999
Davis N Curry A Gambhir AK Panigrahi H Walker CRC Wilkins EGL Worsley MA Kay PR

All surgical operations have the potential for contamination, and the equipment used can harbour bacteria. We collected samples from 100 elective primary hip and knee arthroplasties. These showed rates of contamination of 11.4% for the sucker tips, 14.5% for light handles, 9.4% for skin blades and 3.2% for the inside blades used during surgery; 28.7% of gloves used for preparation were also contaminated. Of the samples taken from the collection bags used during hip arthroplasty, 20% grew bacteria, which represents a significant microbial reservoir. Also, 17% of theatre gowns were contaminated at the end of the operation. Contamination was found in 10% of the needles used during closure of the fascia. Overall, 76% of the organisms grown were coagulase-negative staphylococcus. A total of 63% of operations showed contamination in the field of operation. Some changes in practice are suggested. Follow-up for a minimum of two years revealed one deep infection but the organism was not identified as a contaminant. These data provide a baseline for studying the bacteriology of the surgery of revision arthroplasty.