header advert
Results 1 - 12 of 12
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 360 - 364
1 Mar 2020
Jenkins PJ Stirling PHC Ireland J Elias-Jones C Brooksbank AJ

Aims

The aim of this study was to examine the recent trend in delivery of arthroscopic subacromial decompression (ASD) in Scotland and to determine if this varies by geographical location.

Methods

Scottish Morbidity Records were reviewed retrospectively between March 2014 and April 2018 to identify records for every admission to each NHS hospital. The Office of Population Censuses and Surveys (OPCS-4) surgical codes were used to identify patients undergoing primary ASD. Patients who underwent acromioclavicular joint excision (ACJE) and rotator cuff repair (RCR) were identified and grouped separately. Procedure rates were age and sex standardized against the European standard population.


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 601 - 607
1 May 2016
McClelland D Barlow D Moores TS Wynn-Jones C Griffiths D Ogrodnik PJ Thomas PBM

In arthritis of the varus knee, a high tibial osteotomy (HTO) redistributes load from the diseased medial compartment to the unaffected lateral compartment.

We report the outcome of 36 patients (33 men and three women) with 42 varus, arthritic knees who underwent HTO and dynamic correction using a Garches external fixator until they felt that normal alignment had been restored. The mean age of the patients was 54.11 years (34 to 68). Normal alignment was achieved at a mean 5.5 weeks (3 to 10) post-operatively. Radiographs, gait analysis and visual analogue scores for pain were measured pre- and post-operatively, at one year and at medium-term follow-up (mean six years; 2 to 10). Failure was defined as conversion to knee arthroplasty.

Pre-operative gait analysis divided the 42 knees into two equal groups with high (17 patients) or low (19 patients) adductor moments. After correction, a statistically significant (p < 0.001, t-test,) change in adductor moment was achieved and maintained in both groups, with a rate of failure of three knees (7.1%), and 89% (95% confidence interval (CI) 84.9 to 94.7) survivorship at medium-term follow-up.

At final follow-up, after a mean of 15.9 years (12 to 20), there was a survivorship of 59% (95% CI 59.6 to 68.9) irrespective of adductor moment group, with a mean time to conversion to knee arthroplasty of 9.5 years (3 to 18; 95% confidence interval ± 2.5).

HTO remains a useful option in the medium-term for the treatment of medial compartment osteoarthritis of the knee but does not last in the long-term.

Cite this article: Bone Joint J 2016;98-B:601–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 8 | Pages 1207 - 1207
1 Nov 2003
JASANI V WYNN-JONES C RICHARDS P


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 991 - 993
1 Sep 2002
Jasani V Richards P Wynn-Jones C

Residual pain after total hip due to a number of causes both local to and replacement may be distant from the hip. We describe pain related to the psoas muscle after total hip replacement in nine patients. All presented with characteristic symptoms. We describe the key features and management. Gratifying results were achieved with treatment. This diagnosis should be considered when assessing patients with pain after total hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 64 - 66
1 Jan 1995
Mohammed A Rahamatalla A Wynne-Jones C


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 4 | Pages 586 - 591
1 Jul 1990
Ali M French T Hastings G Rae T Rushton N Ross E Wynn-Jones C

We compared the mechanical properties of carbon fibre composite bone plates with those of stainless steel and titanium. The composite plates have less stiffness with good fatigue properties. Tissue culture and small animal implantation confirmed the biocompatibility of the material. We also present a preliminary report on the use of the carbon fibre composite plates in 40 forearm fractures. All fractures united, 67% of them showing radiological remodelling within six months. There were no refractures or mechanical failures, but five fractures showed an unexpected reaction; this is discussed.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 145 - 145
1 Jan 1990
Collier S Wynn-Jones C


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 4 | Pages 651 - 656
1 Aug 1989
Jones C Dewar M Aichroth P Crawfurd E Emery R

Ten epiphyses in seven children underwent fixed-rate distraction of 0.25 mm twice daily in an attempt to achieve percutaneous leg lengthening by chondrodiatasis. The forces generated across the growth plate were recorded by means of strain gauges incorporated into the distractors. All epiphyses fractured before 33 days of lengthening. An average gain of 6.75 cm was achieved. Epiphyseal distraction at the lower femur produced many complications, but at the upper tibial epiphysis planned lengthening was achieved, with excellent bone production and few complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 1 | Pages 63 - 68
1 Jan 1988
Summers B Turner A Wynn-Jones C

Shelf operations performed on 24 patients (27 hips) for late presentation of congenital hip dysplasia were evaluated. The mean age at operation was 14 years 9 months and the mean follow-up 16 years 8 months. Two-thirds of the hips had good clinical results at follow-up. Patients operated on under the age of 20 years and with little or no radiological evidence of degenerative joint changes had the highest likelihood of success. The shelf operation was found to provide good cover of the femoral head and, should failure occur, also provides adequate superior support for the seating of an acetabular prosthesis.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 312 - 316
1 Mar 1987
Thomas N Turner I Jones C

Four types of prosthetic replacement for the anterior cruciate ligament (carbon fibre, carbon fibre and Dacron composite, Dacron alone and bovine xenograft) were assessed at three, six and 12 months after implantation in the knees of New Zealand white rabbits. The synovium and both intra-articular and intra-osseous portions of the ligaments were examined macroscopically, by light microscopy and by scanning electron microscopy. All the knees showed mild synovitis, and there was no significant growth into the intra-articular part of any ligament. Carbon fibre and xenograft did not appear to be suitable materials in this animal model. The composite ligament showed short-term ingrowth of fibrous tissue only into the periphery of the sheath in its intra-osseous portion, whereas the Dacron ligament showed progressive fibrous tissue ingrowth with some bony incorporation of its outer fibres.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 800 - 803
1 Nov 1985
Ferris B Jones C

Aspergillus infection of the spine is rare; for it to lead to paraplegia is still more rare. When this does occur it is usually treated by decompression and antifungal agents, but the results have usually been poor. We report two cases of successful conservative treatment of Aspergillus paraplegia in patients with chronic granulomatous disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 3 | Pages 358 - 362
1 May 1985
Ker N Jones C

A retrospective study of 32 patients with primary tumours of the cauda equina is presented. Most of the patients were initially diagnosed as having prolapsed intervertebral discs and treated accordingly. The correct diagnosis was eventually made, usually after a long delay, and confirmed by myelography. Treatment consisted of laminectomy and excision of the tumour. Only one tumour was frankly malignant; all the remaining patients were relieved of their pain and the majority recovered completely. The exceptions were those patients with long-standing neurological deficits; this highlights the importance of early diagnosis and correct treatment before irreparable damage occurs.