header advert
Results 1 - 8 of 8
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1434 - 1438
1 Oct 2005
Eckardt H Ding M Lind M Hansen ES Christensen KS Hvid I

The re-establishment of vascularity is an early event in fracture healing; upregulation of angiogenesis may therefore promote the formation of bone. We have investigated the capacity of vascular endothelial growth factor (VEGF) to stimulate the formation of bone in an experimental atrophic nonunion model.

Three groups of eight rabbits underwent a standard nonunion operation. This was followed by interfragmentary deposition of 100 μg VEGF, carrier alone or autograft.

After seven weeks, torsional failure tests and callus size confirmed that VEGF-treated osteotomies had united whereas the carrier-treated osteotomies failed to unite. The biomechanical properties of the groups treated with VEGF and autograft were identical. There was no difference in bone blood flow.

We considered that VEGF stimulated the formation of competent bone in an environment deprived of its normal vascularisation and osteoprogenitor cell supply. It could be used to enhance the healing of fractures predisposed to nonunion.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 6 | Pages 906 - 912
1 Aug 2003
Ding M Odgaard A Hvid I Hvid I

We obtained medial and lateral subchondral cancellous bone specimens from ten human postmortem proximal tibiae with early osteoarthritis (OA) and ten normal age- and gender-matched proximal tibiae. The specimens were scanned by micro-CT and the three-dimensional microstructural properties were quantified.

Medial OA cancellous bone was significantly thicker and markedly plate-like, but lower in mechanical properties than normal bone. Similar microstructural changes were also observed for the lateral specimens from OA bone, although there had been no sign of cartilage damage. The increased trabecular thickness and density, but relatively decreased connectivity suggest a mechanism of bone remodelling in early OA as a process of filling trabecular cavities. This process leads to a progressive change of trabeculae from rod-like to plate-like, the opposite to that of normal ageing. The decreased mechanical properties of subchondral cancellous bone in OA, which are due to deterioration in architecture and density, indicate poor bone quality.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 6 | Pages 900 - 907
1 Aug 2002
Ding M Odgaard A Danielsen CC Hvid I

Previous studies have shown that low-density, rod-like trabecular structures develop in regions of low stress, whereas high-density, plate-like trabecular structures are found in regions of high stress. This phenomenon suggests that there may be a close relationship between the type of trabecular structure and mechanical properties.

In this study, 160 cancellous bone specimens were produced from 40 normal human tibiae aged from 16 to 85 years at post-mortem. The specimens underwent micro-CT and the microstructural properties were calculated using unbiased three-dimensional methods. The specimens were tested to determine the mechanical properties and the physical/compositional properties were evaluated.

The type of structure together with anisotropy correlated well with Young’s modulus of human tibial cancellous bone. The plate-like structure reflected high mechanical stress and the rod-like structure low mechanical stress. There was a strong correlation between the type of trabecular structure and the bone-volume fraction. The most effective microstructural properties for predicting the mechanical properties of cancellous bone seem to differ with age.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 921 - 927
1 Aug 2000
Nafei A Kabel J Odgaard A Linde F Hvid I

We aimed to highlight the relationship between age and the architectural properties of trabecular bone, to outline the patterns in which the variations in these properties take place, and to investigate the influence of the architecture on the mechanical properties of trabecular bone in growing animals. We studied 30 lambs in three age groups and 20 sheep in two age groups. Cubes of subchondral bone were cut from the proximal tibia according to a standardised protocol. They were serially sectioned and their architectural properties were determined. Similar cubes were obtained from the identical anatomical position of the contralateral tibia and their compressive mechanical properties measured. The values obtained from the skeletally immature and mature individuals were compared. Multiple regression analyses were performed between the architectural and the mechanical properties.

The bone volume fraction, the mean trabecular volume, the architectural and the mechanical anisotropy, the elastic modulus, the bone strength, the energy absorption to failure, and the elastic energy correlated positively with increasing age whereas the connectivity density, the bone surface density, the ultimate strain, the absorption of viscoelastic energy and the relative loss of energy correlated inversely. The values of all variables were significantly different in the skeletally mature and immature groups. We determined the patterns in which the variations took place. The bone volume fraction of the trabecular bone tissue was found to be the major predictor of its compressive mechanical properties. Together with the mean trabecular volume and the bone surface density, it explained 81% of the variations in the compressive elastic modulus of specimens obtained from the contralateral tibiae.


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 6 | Pages 910 - 920
1 Aug 2000
Nafei A Danielsen CC Linde F Hvid I

Our aim was to determine the relationship between age and the mechanical and physical properties of trabecular bone, to describe the patterns in which the variations in these properties take place, and to investigate the influence of the physical properties on the mechanical characteristics of trabecular bone during growth. We used 30 lambs in three age groups and 20 sheep in two age groups. Cubes of subchondral bone were cut from the proximal tibia according to a standardised protocol. We performed non-destructive compression tests of the specimens in three orthogonal directions and compression tests to failure in the axial direction. The physical properties of the specimens were also determined. The data were correlated with age and compared in skeletally immature and mature animals. Multiple regression analyses were performed between the mechanical and the physical properties.

Age correlated positively with elastic modulus, bone strength, energy absorption to failure, elastic energy, mechanical anisotropy ratio, tissue density, apparent density, apparent ash density, and bone mineral content, and inversely with ultimate strain, viscoelastic energy absorption, relative energy loss, the collagen content of bone and the percentage porosity. The values of all variables were significantly different in the skeletally mature and immature groups. The apparent density of trabecular bone tissue was found to be the major predictor of its compressive mechanical properties. Together with the content of bone muscle and bone collagen, the apparent density could explain 84% of the variation in the elastic modulus, whereas only a small portion of the variation in ultimate strain could be explained by the variation in apparent density.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 6 | Pages 995 - 1002
1 Nov 1997
Ding M Dalstra M Danielsen CC Kabel J Hvid I Linde F

We tested in compression specimens of human proximal tibial trabecular bone from 31 normal donors aged from 16 to 83 years and determined the mechanical properties, density and mineral and collagen content.

Young’s modulus and ultimate stress were highest between 40 and 50 years, whereas ultimate strain and failure energy showed maxima at younger ages. These age-related variations (except for failure energy) were non-linear.

Tissue density and mineral concentration were constant throughout life, whereas apparent density (the amount of bone) varied with ultimate stress. Collagen density (the amount of collagen) varied with failure energy. Collagen concentration was maximal at younger ages but varied little with age.

Our results suggest that the decrease in mechanical properties of trabecular bone such as Young’s modulus and ultimate stress is mainly a consequence of the loss of trabecular bone substance, rather than a decrease in the quality of the substance itself. Linear regression analysis showed that collagen density was consistently the single best predictor of failure energy, and collagen concentration was the only predictor of ultimate strain.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 6 | Pages 803 - 806
1 Nov 1992
Kristensen O Nafei A Kjaersgaard-Andersen P Hvid I Jensen J

We have reviewed at an average period of ten years the results of 71 consecutive primary arthroplasties with the Insall-Burstein total condylar knee prosthesis in patients with rheumatoid arthritis. Their mean age at surgery was 52 years (24 to 72). At follow-up the overall results (Hospital for Special Surgery knee rating score) were excellent or good in 77%, fair in 11% and poor in 11%. There was residual pain in only 5% of patients with prostheses in situ; 58% could walk more than 500 m, and the median range of motion was 108 degrees. Eight knees had been revised. Five underwent arthrodesis because of deep infection and three needed revision arthroplasty for mechanical loosening. The crude survival rate of the arthroplasties was 89%. The presence of radiolucency around the tibial component correlated significantly with the severity of residual pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 243 - 246
1 Mar 1992
Nafei A Nielsen S Kristensen O Hvid I

We report the results of 75 consecutive primary press-fit Kinemax arthroplasties with an average follow-up of 14 months (three to 28). We reviewed 26 cemented and 49 non-cemented tibial components implanted into 72 patients (30 men and 42 women, median age 70 years). At the latest follow-up the overall evaluation (Hospital for Special Surgery knee rating scale) for cemented cases was excellent in 54%, good in 42% and poor in 4%. No cemented prosthesis loosened. Of the non-cemented cases 55% were excellent, 23% good, and 2% fair. Ten tibial implants (20%) loosened and required revision. Residual pain marred the result in 24% of the non-cemented prostheses and in 4% of the cemented group. We do not recommend the press-fit, smooth-surfaced Kinemax prosthesis for non-cemented use.