header advert
Results 1 - 2 of 2
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 2 | Pages 194 - 200
1 Feb 2016
Tsukada S Wakui M Hoshino A

There is conflicting evidence about the benefit of using corticosteroid in periarticular injections for pain relief after total knee arthroplasty (TKA). We carried out a double-blinded, randomised controlled trial to assess the efficacy of using corticosteroid in a periarticular injection to control pain after TKA.

A total of 77 patients, 67 women and ten men, with a mean age of 74 years (47 to 88) who were about to undergo unilateral TKA were randomly assigned to have a periarticular injection with or without corticosteroid. The primary outcome was post-operative pain at rest during the first 24 hours after surgery, measured every two hours using a visual analogue pain scale score. The cumulative pain score was quantified using the area under the curve.

The corticosteroid group had a significantly lower cumulative pain score than the no-corticosteroid group during the first 24 hours after surgery (mean area under the curve 139, 0 to 560, and 264, 0 to 1460; p = 0.024). The rate of complications, including surgical site infection, was not significantly different between the two groups up to one year post-operatively.

The addition of corticosteroid to the periarticular injection significantly decreased early post-operative pain. Further studies are needed to confirm the safety of corticosteroid in periarticular injection.

Take home message: The use of corticosteroid in periarticular injection offered better pain relief during the initial 24 hours after TKA.

Cite this article: Bone Joint J 2016;98-B:194–200.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 807 - 811
1 Nov 1987
Hoshino A Wallace W

A biomechanical study has been carried out on 20 cadaveric knees to investigate their load-absorbing mechanism. The impact load was applied using a weight falling onto the transected proximal femur and the force transmitted through the knee was measured at the transected distal tibia using a load transducer. The peak force transmitted increased as, sequentially, meniscus, articular cartilage and subchondral bone were damaged or removed. The most striking result was found in an implanted knee replacement where the transmitted force reached 180% of that in the intact knee. The results show that the joint has an impact-absorbing property in each segment and that in the osteoarthritic knee there is less absorption of shock than in the normal knee. The high impact force in an implanted knee suggests that microfractures of the cancellous bone might be expected and may produce loosening.