header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 939 - 944
1 Jul 2016
Boonen B Schotanus MGM Kerens B van der Weegen W Hoekstra HJ Kort NP

Aims

We wished to compare the clinical outcome, as assessed by questionnaires and the rate of complications, in total knee arthroplasty (TKA) undertaken with patient-matched positioning guides (PMPGs) or conventional instruments.

Patients and Methods

A total of 180 patients (74 men, 106 women; mean age 67 years) were included in a multicentre, adequately powered, double-blind, randomised controlled trial. The mean follow-up was 44 months (24 to 57).


The Bone & Joint Journal
Vol. 96-B, Issue 11 | Pages 1540 - 1545
1 Nov 2014
Dierselhuis EF van den Eerden PJM Hoekstra HJ Bulstra SK Suurmeijer AJH Jutte PC

Atypical cartilaginous tumours are usually treated by curettage. The purpose of this study was to show that radiofrequency ablation was an effective alternative treatment.

We enrolled 20 patients (two male, 18 female, mean age 56 years (36 to 72) in a proof-of-principle study. After inclusion, biopsy and radiofrequency ablation were performed, followed three months later by curettage and adjuvant phenolisation. The primary endpoint was the proportional necrosis in the retrieved material. Secondary endpoints were correlation with the findings on gadolinium enhanced MRI, functional outcome and complications.

Our results show that 95% to 100% necrosis was obtained in 14 of the 20 patients. MRI had a 91% sensitivity and 67% specificity for detecting residual tumour after curettage. The mean functional outcome (MSTS) score six weeks after radiofrequency ablation was 27.1 (23 to 30) compared with 18.1 (12 to 25) after curettage (p < 0.001). No complications occurred after ablation, while two patients developed a pathological fracture after curettage.

We have shown that radiofrequency ablation is capable of completely eradicating cartilaginous tumour cells in selective cases. MRI has a 91% sensitivity for detecting any residual tumour. Radiofrequency ablation can be performed on an outpatient basis allowing a rapid return to normal activities. If it can be made more effective, it has the potential to provide better local control, while improving functional outcome.

Cite this article: Bone Joint J 2014;96-B:1540–5.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1626 - 1631
1 Dec 2013
van der Weegen W Brakel K Horn RJ Hoekstra HJ Sijbesma T Pilot P Nelissen RGHH

The aim of this study was to establish the natural course of unrevised asymptomatic pseudotumours after metal-on-metal (MoM) hip resurfacing during a six- to 12-month follow-up period. We used repeated metal artefact reduction sequence (MARS)-magnetic resonance imaging (MRI), serum metal ion analysis and clinical examination to study 14 unrevised hips (mean patient age 52.7 years, 46 to 68, 5 female, 7 male) with a pseudotumour and 23 hips (mean patient age 52.8 years, 38 to 69, 7 female, 16 male) without a pseudotumour. The mean post-operative time to the first MARS-MRI scan was 4.3 years (2.2 to 8.3), and mean time between the first and second MARS-MRI scan was eight months (6 to 12). At the second MRI scan, the grade of severity of the pseudotumour had not changed in 35 hips. One new pseudotumour (Anderson C2 score, moderate) was observed, and one pseudotumour was downgraded from C2 (moderate) to C1 (mild). In general, the characteristics of the pseudotumours hardly changed.

Repeated MARS-MRI scans within one year in patients with asymptomatic pseudotumours after MoM hip resurfacing showed little or no variation. In 23 patients without pseudotumour, one new asymptomatic pseudotumour was detected.

This is the first longitudinal study on the natural history of pseudotumours using MARS-MRI scans in hip resurfacing, and mirrors recent results for 28 mm diameter MoM total hip replacement.

Cite this article: Bone Joint J 2013;95-B:1626–31.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 298 - 306
1 Mar 2011
van der Weegen W Hoekstra HJ Sijbesma T Bos E Schemitsch EH Poolman RW

We systematically reviewed the peer-reviewed literature to relate the survival of hybrid metal-on-metal hip resurfacing arthroplasty devices to a National Institute of Clinical Excellence (NICE) benchmark for choosing a primary total hip replacement, which is a survival rate of 90% at a follow-up of ten years.

A total of 29 articles (10 621 resurfaced hips) met the inclusion criteria. The mean follow-up ranged from 0.6 to 10.5 years and the survival of the implant ranged from 84% to 100%. Of the 10 621 hips, 370 were revised (3.5%), with aseptic loosening as the most frequent mode of failure.

None of the hip resurfacing arthroplasty implants used to date met the full ten-year NICE benchmark of survival. A total of 13 studies showed satisfactory survival compared with the three-year NICE benchmark.