header advert
Results 1 - 6 of 6
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 374 - 378
1 May 1997
Hedlundh U Sanzén L Fredin H

We studied the risk of recurrent dislocation in 121 primary and 39 revision Charnley or Charnley hybrid total hip arthroplasties which had been treated for a primary dislocation between 1979 and 1995. Only 35% of these hips had no further dislocation or a revision for instability within one year. The rates of survival gradually declined with time or if a second, third or fourth dislocation occurred. The risk of recurrence was greater in men, but was not related to age, diagnosis, time of the first dislocation or whether the index operation had been a primary or a revision procedure.

Operative treatment included 15 reoperations leaving intact components, 50 revisions, and permanent removal of the femoral stem in seven patients. The operation was successful in four patients with reoperations and in 36 who had an exchange procedure within two years. Treatment was successful in 35 of 49 hips in which it was possible to correct a technical error compared with 5 out of 16 hips in which malposition of the components was not seen (p = 0.007).


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 996 - 996
1 Nov 1996
BENONI G FREDIN H


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 3 | Pages 434 - 440
1 May 1996
Benoni G Fredin H

We investigated the effect of a fibrinolytic inhibitor, tranexamic acid, on blood loss and blood transfusion in knee arthroplasty by a randomised, double-blind study of 86 patients. A dose of 10 mg/kg body-weight of either tranexamic acid or placebo was given intravenously shortly before the release of the tourniquet, and repeated three hours later. The mean total blood loss was 730 ± 280 ml in the tranexamic acid group as against 1410 ± 480 ml in the placebo group (p < 0.001).

Both the number of patients receiving blood transfusion and the number of blood units transfused were reduced to one-third in the treated group, and mean postoperative Hb concentrations were significantly higher after prophylaxis. The number of thromboembolic complications was the same in both groups. Tranexamic acid should be given prophylactically in order to be effective.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 206 - 209
1 Mar 1996
Hedlundh U Ahnfelt L Hybbinette C Weckström J Fredin H

We studied the effect of surgical experience on the dislocation rate after 4230 primary total hip arthroplasties (THAs) all performed using the posterior approach at three orthopaedic centres at major county hospitals. There were 129 postoperative (3%) dislocations.

Twice the number of dislocations were registered for inexperienced surgeons as for their more experienced colleagues. This frequency of dislocation levelled off with increasing numbers of operations and remained constant after approximately 30. For every ten primary THAs performed annually, the risk of dislocation decreased by 50%.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 164 - 165
1 Jan 1992
Fredin H


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 3 | Pages 430 - 433
1 May 1991
Fredin H Sanzen L Sigurdsson B Unander-Scharin L

Total arthroplasty was performed on 21 congenitally dislocated hips in 18 women. In all cases the femoral head was dislocated cranially at least one-fifth of the height of the pelvis. The components were both cemented, the acetabulum being replaced to its original position. The acetabular roof was reconstructed by bone graft in 13 hips, and trochanteric osteotomy was done in 18 hips. The patients were assessed at a median follow-up time of 7.5 years when their median age was 54 years. Nine patients had been revised or required revision. At follow-up the average functional score (according to Charnley) was 6 for pain, 4 for walking ability and 5 for range of motion. The Harris hip score was 82. The patients' subjective evaluation of their satisfaction with the late results on a visual analogue scale was 93, range 23 to 100. The high loosening rate in such patients demands regular follow-up and preparedness for revision surgery.