Bone & Joint Research
Vol. 12, Issue 3 | Pages 155 - 164
1 Mar 2023
McCarty CP Nazif MA Sangiorgio SN Ebramzadeh E Park S

Aims

Taper corrosion has been widely reported to be problematic for modular total hip arthroplasty implants. A simple and systematic method to evaluate taper damage with sufficient resolution is needed. We introduce a semiquantitative grading system for modular femoral tapers to characterize taper corrosion damage.

Methods

After examining a unique collection of retrieved cobalt-chromium (CoCr) taper sleeves (n = 465) using the widely-used Goldberg system, we developed an expanded six-point visual grading system intended to characterize the severity, visible material loss, and absence of direct component contact due to corrosion. Female taper sleeve damage was evaluated by three blinded observers using the Goldberg scoring system and the expanded system. A subset (n = 85) was then re-evaluated following destructive cleaning, using both scoring systems. Material loss for this subset was quantified using metrology and correlated with both scoring systems.


The Bone & Joint Journal
Vol. 99-B, Issue 8 | Pages 1109 - 1114
1 Aug 2017
Lang PJ Avoian T Sangiorgio SN Nazif MA Ebramzadeh E Zionts LE

Aims

After the initial correction of congenital talipes equinovarus (CTEV) using the Ponseti method, a subsequent dynamic deformity is often managed by transfer of the tendon of tibialis anterior (TATT) to the lateral cuneiform. Many surgeons believe the lateral cuneiform should be ossified before surgery is undertaken. This study quantifies the ossification process of the lateral cuneiform in children with CTEV between one and three years of age.

Patients and Methods

The length, width and height of the lateral cuneiform were measured in 43 consecutive patients with unilateral CTEV who had been treated using the Ponseti method. Measurements were taken by two independent observers on standardised anteroposterior and lateral radiographs of both feet taken at one, two and three years of age.


Bone & Joint Research
Vol. 6, Issue 2 | Pages 90 - 97
1 Feb 2017
Rajfer RA Kilic A Neviaser AS Schulte LM Hlaing SM Landeros J Ferrini MG Ebramzadeh E Park S

Objectives

We investigated the effects on fracture healing of two up-regulators of inducible nitric oxide synthase (iNOS) in a rat model of an open femoral osteotomy: tadalafil, a phosphodiesterase inhibitor, and the recently reported nutraceutical, COMB-4 (consisting of L-citrulline, Paullinia cupana, ginger and muira puama), given orally for either 14 or 42 days.

Materials and Methods

Unilateral femoral osteotomies were created in 58 male rats and fixed with an intramedullary compression nail. Rats were treated daily either with vehicle, tadalafil or COMB-4. Biomechanical testing of the healed fracture was performed on day 42. The volume, mineral content and bone density of the callus were measured by quantitative CT on days 14 and 42. Expression of iNOS was measured by immunohistochemistry.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 428 - 436
1 Apr 2001
Lovász G Park SH Ebramzadeh E Benya PD Llinás A Bellyei Á Luck JV Sarmiento A

To investigate the effect of instability on the remodelling of a minor articular surface offset, we created a 0.5 mm coronal step-off of the medial femoral condyle in 12 New Zealand white rabbits and transected the anterior cruciate ligament (ACL). A control group of 12 rabbits had only ACL resection and the opposite knee was used as the non-operated control. The osteoarthritic changes at 6, 12 and 24 weeks after surgery were evaluated histologically. In addition, changes in the immunological detection of 3-B-3(-) and 7-D-4 chondroitin-6-sulphate epitopes were determined because of the previous association of such changes with repair of cartilage and early osteoarthritis.

In the instability/step-off group there was rapidly progressing focal degeneration of cartilage on the high side of the defect, not seen in previous step-off studies in stable knees. The rest of the femoral condyles and the tibial plateaux of the instability/step-off group had moderate osteoarthritis similar to that of the instability group. 3-B-3(-) was detectable in the early and the intermediate stages of osteoarthritis but no staining was seen in the severely damaged cartilage zones. Immunoreactivity with 7-D-4 increased as degeneration progressed.

Our findings have shown that even a minor surface offset may induce rapid degeneration of cartilage when the stability of the knee is compromised.


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 902 - 907
1 Nov 1991
Llinas A Sarmiento A Ebramzadeh E Gogan W McKellop H

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to 20 years). The performance of the secondary total hip replacements varied with the preceding implant and was different for acetabular and femoral components. The incidence of radiological loosening was higher for femoral components implanted after failed hemiarthroplasties and for acetabular components after failed mould arthroplasties. However, the incidence of continuous radiolucent lines was lower for the acetabular components of converted hemiarthroplasties than for the primary replacements.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 996 - 1002
1 Nov 1990
Sarmiento A Ebramzadeh E Gogan W McKellop H

We reviewed the radiographs of 864 Charnley and STH (Zimmer) cemented total hip arthroplasties with a mean follow-up of seven years (maximum 16 years). Survivorship analysis was used to assess the correlation between radiographic performance and the bony containment or the coronal orientation of the acetabular cup. The cup orientation and containment were interrelated; all vertically oriented cups were completely contained, whereas 25% of more horizontal cups were only partially contained. Completely contained cups had significantly lower incidences of complete cement-bone radiolucency (p = 0.02) and of wear (p = 0.09). Vertically oriented cups had a lower incidence of continuous radiolucency than neutrally oriented cups, but this was not statistically significant (p = 0.25). Our results confirm the importance of complete bony containment, and also indicate that it is better to accept vertical orientation and obtain full bony coverage than to have a more horizontal orientation with partial containment.