header advert
Results 1 - 20 of 22
Results per page:
The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 107 - 115
1 Jan 2017
Carr A Cooper C Campbell MK Rees J Moser J Beard DJ Fitzpatrick R Gray A Dawson J Murphy J Bruhn H Cooper D Ramsay C

Aims

The appropriate management for patients with a degenerative tear of the rotator cuff remains controversial, but operative treatment, particularly arthroscopic surgery, is increasingly being used. Our aim in this paper was to compare the effectiveness of arthroscopic with open repair of the rotator cuff.

Patients and Methods

A total of 273 patients were recruited to a randomised comparison trial (136 to arthroscopic surgery and 137 to open surgery) from 19 teaching and general hospitals in the United Kingdom. The surgeons used their usual preferred method of repair. The Oxford Shoulder Score (OSS), two years post-operatively, was the primary outcome measure. Imaging of the shoulder was performed at one year after surgery. The trial is registered with Current Controlled Trials, ISRCTN97804283.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1648 - 1655
1 Dec 2016
Murphy J Gray A Cooper C Cooper D Ramsay C Carr A

Aims

A trial-based comparison of the use of resources, costs and quality of life outcomes of arthroscopic and open surgical management for rotator cuff tears in the United Kingdom NHS was performed using data from the United Kingdom Rotator Cuff Study (UKUFF) randomised controlled trial.

Patients and Methods

Using data from 273 patients, healthcare-related use of resources, costs and quality-adjusted life years (QALYs) were estimated at 12 months and 24 months after surgery on an intention-to-treat basis with adjustment for covariates. Uncertainty about the incremental cost-effectiveness ratio for arthroscopic versus open management at 24 months of follow-up was incorporated using bootstrapping. Multiple imputation methods were used to deal with missing data.


Bone & Joint Research
Vol. 5, Issue 6 | Pages 206 - 214
1 Jun 2016
Malak TT Broomfield JAJ Palmer AJR Hopewell S Carr A Brown C Prieto-Alhambra D Glyn-Jones S

Objectives

High failure rates of metal-on-metal hip arthroplasty implants have highlighted the need for more careful introduction and monitoring of new implants and for the evaluation of the safety of medical devices. The National Joint Registry and other regulatory services are unable to detect failing implants at an early enough stage. We aimed to identify validated surrogate markers of long-term outcome in patients undergoing primary total hip arthroplasty (THA).

Methods

We conducted a systematic review of studies evaluating surrogate markers for predicting long-term outcome in primary THA. Long-term outcome was defined as revision rate of an implant at ten years according to National Institute of Health and Care Excellence guidelines. We conducted a search of Medline and Embase (OVID) databases. Separate search strategies were devised for the Cochrane database and Google Scholar. Each search was performed to include articles from the date of their inception to June 8, 2015.


Bone & Joint Research
Vol. 3, Issue 3 | Pages 48 - 50
1 Mar 2014
Lidgren L Gomez-Barrena E N. Duda G Puhl W Carr A


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 8 | Pages 1221 - 1221
1 Nov 2004
CARR A


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 877 - 882
1 Aug 2001
Dawson J Hill G Fitzpatrick R Carr A

We carried out a prospective study of 93 patients undergoing surgery for conditions of the rotator cuff during 1994 and 1995. They were assessed before operation and after six months, and four years, using the patient-based Oxford Shoulder Score (OSS), the SF-36 questionnaire and the Constant shoulder score. The response rates were higher for the OSS and SF-36. The correlation coefficients were high (r > 0.5) between all scores at each stage of the study. While all scores improved substantially at six months, the Constant score was reduced significantly at four years. This did not correlate with the patients’ judgement of the change in symptoms or of the success of the operation. Our study suggests that patient-based measures of pain and function can reliably assess outcomes in the medium term after surgery to the shoulder.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 313 - 315
1 Apr 2001
Dawson J Carr A


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 420 - 426
1 May 1999
Dawson J Fitzpatrick R Carr A

We have developed a 12-item questionnaire for completion by patients presenting with shoulder instability. A prospective study of 92 patients was undertaken involving two assessments, approximately six months apart, performed in an outpatient department. Each patient completed the new questionnaire and the SF36 form. An orthopaedic surgeon completed the Constant shoulder score and the Rowe assessment.

The new questionnaire and the Rowe clinical score each achieved a large standardised effect size (≥0.8) and compared favourably with relevant items on the SF36. By contrast, the Constant score barely registered any effect, confirming that it may be relatively insensitive to changes in clinical status for this particular condition.

The questionnaire provides a measurement of outcome for shoulder instability which is short, practical, reliable, valid and sensitive to changes of clinical importance.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 63 - 69
1 Jan 1998
Dawson J Fitzpatrick R Murray D Carr A

We have developed a 12-item questionnaire for patients having a total knee replacement (TKR). We made a prospective study of 117 patients before operation and at follow-up six months later, asking them to complete the new questionnaire and the form SF36. Some also filled in the Stanford Health Assessment Questionnaire (HAQ). An orthopaedic surgeon completed the American Knee Society (AKS) clinical score.

The single score derived from the new questionnaire had high internal consistency, and its reproducibility, examined by test-retest reliability, was found to be satisfactory. Its validity was established by obtaining significant correlations in the expected direction with the AKS scores and the relevant parts of the SF36 and HAQ. Sensitivity to change was assessed by analysing the differences between the preoperative scores and those at follow-up.

We also compared change in scores with the patients’ retrospective judgement of change in their condition. The effect size for the new questionnaire compared favourably with those for the relevant parts of the SF36. The change scores for the new knee questionnaire were significantly greater (p < 0.0001) for patients who reported the most improvement in their condition.

The new questionnaire provides a measure of outcome for TKR that is short, practical, reliable, valid and sensitive to clinically important changes over time.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 4 | Pages 593 - 600
1 Jul 1996
Dawson J Fitzpatrick R Carr A

We developed a 12-item questionnaire for completion by patients having shoulder operations other than stabilisation. A prospective study of 111 patients was undertaken before operation and at follow-up six months later. Each patient completed the new questionnaire and the SF36 form. Some filled in the Stanford Health Assessment Questionnaire (HAQ). An orthopaedic surgeon assessed the Constant shoulder score.

The single score derived from the questionnaire had a high internal consistency. Reproducibility, examined by test-retest reliability, was found to be satisfactory. The validity of the questionnaire was established by obtaining significant correlations in the expected direction with the Constant score and the relevant scales of the SF36 and the HAQ. Sensitivity to change was assessed by analysing the differences between the preoperative scores and those at follow-up. Changes in scores were compared with the patients’ responses to postoperative questions about their condition. The standardised effect size for the new questionnaire compared favourably with that for the SF36 and the HAQ. The new questionnaire was the most efficient in distinguishing patients who said that their shoulder was much better from all other patients.

The shoulder questionnaire provides a measure of outcome for shoulder operations which is short, practical, reliable, valid and sensitive to clinically important changes.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 185 - 190
1 Mar 1996
Dawson J Fitzpatrick R Carr A Murray D

We developed a 12-item questionnaire for completion by patients having total hip replacement (THR). A prospective study of 220 patients was undertaken before operation and at follow-up six months later. Each completed the new questionnaire as well as the SF36, and some the Arthritis Impact Measurement Scales (AIMS). An orthopaedic surgeon assessed the Charnley hip score.

The single score derived from the questionnaire had a high internal consistency. Reproducibility was examined by test-retest reliability and was found to be satisfactory. The validity of the questionnaire was established by obtaining significant correlation in the expected direction with the Charnley scores and relevant scales of the SF36 and the AIMS. Sensitivity to change was assessed by analysing the differences between the preoperative scores and those at the follow-up. The standardised effect size for the new questionnaire compared favourably with that for the SF36 and the AIMS.

The new questionnaire provides a measure of outcome for THR which is short, practical, reliable, valid and sensitive to clinically important changes.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 5 | Pages 820 - 829
1 Sep 1995
Carr A Smith R Athanasou N Woods C

The clinical features, investigation, treatment and outcome of two adults with fibrogenesis imperfecta ossium are described. In this rare acquired disorder of bone, normal lamellar collagen is replaced by structurally unsound collagen-deficient tissue, which leads to extreme bone fragility and ununited fractures. Transmission microscopy and SEM showed striking ultrastructural changes in bone structure and mineralisation. Both patients had monoclonal IgG paraproteins in the plasma and one excreted monoclonal lambda light chains in the urine. No abnormal plasma cells were found in the bone marrow and there was no evidence of amyloid deposition in the tissues. In both patients initial treatment with 1 alpha-hydroxycholecalciferol appeared to be ineffective, but in one, repeated courses of melphalan and corticosteroids over three years together with 1 alpha-hydroxycholecalciferol produced striking clinical and histological improvement. The findings in these and other patients strongly suggest that paraproteinaemia is an integral feature of fibrogenesis imperfecta ossium, and this needs further investigation.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 4 | Pages 520 - 527
1 Jul 1995
Murray D Carr A Bulstrode C

To assist surgeons to select a total hip replacement (THR) we present comparative information on all such implants on the market in the UK. We identified 62 different primary THRs, manufactured by 19 companies; half had been introduced in the last five years, and only 30% have any results published in peer-reviewed journals. The prices range from 250 pounds to 2000 pounds, and the two cheapest implants have the longest reported follow-up. The number of THR implants available in the UK, and presumably the rest of the world, is rapidly increasing, but there is little or no scientific evidence that the newer, more expensive, implants are better than established designs. Some will undoubtedly be worse. We believe that this situation is unsatisfactory and make recommendations for improvement, in particular that preference be given to implants with good results in published peer-reviewed long-term clinical trials.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 1 | Pages 3 - 5
1 Jan 1995
Murray D Carr A Bulstrode C


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 697 - 704
1 Sep 1993
Murray D Carr A Bulstrode C

Survival analysis is a powerful tool for analysing the results of total joint replacement, but it has major drawbacks when the failure rates are very low. We have reviewed 35 recent survival analyses of joint replacements to assess the magnitude of these problems and make recommendations as to how they may be avoided.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 4 | Pages 582 - 591
1 Jul 1993
Carr A Cole W Roberton D Chow C

We describe 22 patients who presented between the ages of 4 and 14 years with gradual onset of malaise and pain at the sites of multiple bone lesions. The symptoms from the bone lesions were sometimes sequential in onset and often relapsing. The radiological findings were typical of osteomyelitis. Radioisotope bone scans identified some clinically silent lesions. Bone biopsies were performed in 20 patients and the changes of osteomyelitis were seen in 17; microbiological culture was positive in only one. Seven patients had polyarthritis, two had palmoplantar pustulosis and one had psoriasis. Some symptomatic relief was obtained with anti-inflammatory agents and, to a less extent, with antibiotics. No patient had primary immunodeficiency. The mean duration of symptoms from the bone lesions was two years (1 to 4). When arthritis was present the joint symptoms lasted considerably longer (mean 7 years; range 4 to 10). The long-term prognosis was generally good. There was no evidence of altered bone growth or abnormal joint development. One patient developed a progressive kyphosis requiring fusion, but no other surgical intervention was necessary.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 178 - 182
1 Mar 1993
Carr A Morris R Murray D Pynsent P


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 76 - 78
1 Jan 1993
Carr A Jefferson R Benson M

We measured the range of rotation in both hips of 397 normal children and in the unaffected hip of 135 children with unilateral congenital dislocation of the hip. Both groups were assessed for generalised joint laxity. Joint laxity was more common in normal children with an internally centred arc of hip rotation than in normal children with a neutral or an externally rotated arc. The children with congenitally dislocated hips had significantly more joint laxity than did the control group and significantly more of them had an internally centred arc of hip rotation. We suggest that the lax joint capsule fails to mould away the neonatal anteversion of the femoral neck during the first few months of life.


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1077 - 1077
1 Nov 1990
Carr A


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 1 | Pages 144 - 144
1 Jan 1990
Carr A