header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (sd 33 900) vs 12 800 cycles (sd 6100); p = 0.007) and mean axial stiffness (220 N/mm (sd 80) vs 70 N/mm (sd 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (sd 0.9) vs 5.1 Nm/° (sd 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (sd 25 600) vs 52 400 cycles (sd 22 500); p = 0.04).

The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients.

Cite this article: Bone Joint J 2014;96-B:114–21.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 699 - 703
1 Nov 1987
Gibson M Szypryt E Buckley J Worthington B Mulholland R

Magnetic resonance imaging (MRI) was used to compare the appearance of the spine in 20 adolescents with proven symptomatic intervertebral disc herniations with that in 20 asymptomatic patients who acted as controls. Abnormality in the signal from the nucleus pulposus of one or more discs was present in all patients, while only four of the 20 controls had any abnormal signals. In all the patients the symptomatic disc produced an abnormal signal and in most a herniated fragment of the nucleus pulposus was identified. Fifteen of the 20 patients had multiple-disc abnormality: six had three abnormal discs and nine had two. This suggests there was an underlying diathesis in patients who later developed disc herniation.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 5 | Pages 719 - 723
1 Nov 1986
Gibson M Buckley J Mulholland R Worthington B

Magnetic resonance imaging (MRI) of the spine produces images which reflect the chemical composition of the intervertebral disc. We have conducted a prospective study of the serial changes in the MRI appearance of the intervertebral disc after chemonucleolysis with the enzyme chymopapain. Fourteen patients were studied after single-level chemonucleolysis and the results compared with a control group of 17 discs in six patients who had diagnostic discography without enzyme insertion. A consistent pattern of gradual loss of signal from the nucleus pulposus culminating in complete loss of nuclear signal was seen in all cases after chemonucleolysis. Chymopapain therefore produced MRI changes analogous with premature gross disc degeneration. The rate at which this occurred varied; complete loss of signal took at least six weeks. Transitory minor end-plate changes were present in five patients, probably representing a mild chemical discitis. No similar changes were seen in the discography group.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 369 - 373
1 May 1986
Gibson M Buckley J Mawhinney R Mulholland R Worthington B

The lumbar spines of 22 patients were examined for disc degeneration by magnetic resonance imaging (MRI) and by discography. The results from 50 intervertebral discs visualised by both techniques were independently assessed and graded on a five-point scale from normality to gross degeneration and then compared. In 44 discs the results agreed. Of the six discs which gave differing results, four discrepancies were due to observer error and two to incorrect placement of the discographic needle. MRI was shown to be more accurate than discography in the diagnosis of disc degeneration. It has several major advantages, which should make it the investigation of choice.