The anatomic abnormalities are observed in developmental dysplasia of the hip (DDH) and it is challenging to perform the total hip arthroplasty (THA) for some DDH patients. If acetabular cup was placed at the original acetabular position in patients with high hip dislocation, it may be difficult to perform reduction of hip prosthesis because of soft tissue contracture. The procedures resolving this problem were to use femoral shortening osteotomy, or to place the acetabular cup at a higher cup position than the original hip center. Femoral shortening osteotomy has some concerns about its complicated procedure, time consuming, and risk of non-union. Conversely, implantation of the acetabular cup at the higher cup position may eliminate these shortcomings and this procedure is considered to be preferred if possible. However, the criteria of cases without femoral shortening osteotomy are not clear. In this study, we retrospectively analysed the clinical outcomes of patients performed THAs for high hip dislocation, and clarified the adaptation of THA with or without femoral shortening osteotomy. We included a total of 65 hip joints from 57 patients who underwent primary THA using Modulus stem for high hip dislocation from November 2007 to December 2015 at our institution. The mean follow up period was 5.2 years (2 – 10 years). The mean age at surgery was 65.4 years (Table 1). Thirty seven hips were classified as Crowe III, and twenty eight hips as Crowe IV based on Crowe classification. We classified patients into two groups based on the use of femoral osteotomy. Then, we compared the surgical time, blood loss, Japanese Orthopaedic Association (JOA) Score as clinical outcomes, preoperative position of the greater trochanter, the cup position, and complications between two groups. The position of the greater trochanter was measured the height of the tip of greater trochanter from the inter teardrop line. The cup center position was assessed by measuring the distance between the cup center and ipsilateral tear drop. Receiver operating characteristic (ROC) curves were plotted for deciding the cut-off value for the height of the greater trochanter. The cut-off value presented the maximum sensitivity and specificity was determined.Introduction
Methods
The purpose of this study was to compare two different types
of metal-on-metal (MoM) bearing for total hip arthroplasty (THA):
one with a large femoral head (38 mm to 52 mm) and the other with
a conventional femoral head (28 mm or 32 mm). We compared clinical
outcome, blood metal ion levels, and the incidence of pseudotumour in
the two groups. Between December 2009 and December 2011, 62 patients underwent
MoM THA with a large femoral head (Magnum group) and 57 patients
an MoM THA with a conventional femoral head (conventional group).
Clinical outcome was assessed using the Harris Hip score, University
of California, Los Angeles (UCLA) activity score and EuroQol-5D
(EQ-5D). Blood metal ion levels were measured and MRI scans were
analyzed at a minimum of five years postoperatively.Aims
Patients and Methods