header advert
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 9 - 9
1 Jul 2022
Fleming T Torrie A Murphy T Dodds A Engelke D Curwen C Gosal H Pegrum J
Full Access

Abstract

INTRODUCTION

COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning

METHODOLOGY

50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 5 - 5
1 Oct 2017
Miller A Stenning M Torrie A Issac A Hutchinson J Hutchinson J Chopra I Mohanty K
Full Access

Bertolotti first described articulation of the L5 transverse process with the sacrum as a cause of back pain in 1917. Since then little attention has been payed to these atypical articulations despite their high reported incidence.

Here we describe our early experience of surgical treatment and propose a validated CT based classification of lumbosacral segment abnormalities (LSSA).

400 lumbosacral CT scans were reviewed (NBT), a classification devised and incidence of abnormalities recorded. 40 patients were selected and 4 independent observers classified each scan. Case notes for all patients (C&V) who received steroid injections into or surgical excision of LSSAs were reviewed. Results as follows:

5 types of abnormality were identified.

Type 0 - normal

Type 1 - asymmetrical shortening of the iliolumbar ligament

Type 2 - transverse process of L5 within 2mm of the sacrum

Type 3 - diarthrodial joint (3A: no evidence of degeneration 3B: degenerative change)

Type 4 - transverse process and sacrum have fused

Type 5 - extends to L4

54.5% of patients had abnormalities. The kappa values for the intra-observer results were 0.69 to 0.88 and the inter-observer ratings gave a combined score of over 0.7 indicating substantial agreement.

Our CT classification of LSSAs is both straight forward to use and repeatable. The incidence of these abnormalities is higher in our population of CT scans compared to previous published series using plain radiographs. All patients treated with surgical excision of established articulations (Type 3A or above) reported good or excellent outcomes following excision.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 16 - 16
1 May 2015
Torrie A Harding I Hutchinson J Nelson I Adams M Dolan P
Full Access

The study aim was to simulate oblique spinous process abutment (SPA) in cadaveric spines and determine how this affects coupled motion in the coronal plane.

L4-S1 spinal segments from thirteen cadavers were loaded on a materials testing machine in pure compression at 1kN for 10 minutes. Reflective markers on the vertebral bodies were used to assess coronal motion using a motion analysis system. Oblique SPA was simulated by attaching moulded oblique aluminium strips to the L4 and L5 spinous processes. In each specimen, both a right- and left-sided SPA was simulated, in random order, and compression at 1kN was again applied. All tests were then repeated after endplate fracture. Coronal plane motion at baseline was compared with values following simulated SPA using Mann Whitney U-tests.

Pre-fracture, SPA increased coronal motion by 0.28° and 0.34° on right and left sides respectively, compared to baseline, only the former was significant (P=0.03). Post-fracture, SPA decreased coronal motion by 0.36° and 0.46° on right and left sides respectively, only the latter was significant (P=0.03). Simulated oblique SPA in the intact spine initiated an increase in coronal motion during pure axial loading. These findings provide limited evidence that oblique SPA may be causative in DLS.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 28 - 28
1 Apr 2014
Lavelle D Morris S Torrie A Katsimihas M Hutchinson J Harding I Nelson I
Full Access

Aim:

Deep infection following paediatric spinal deformity surgery is a serious complication, which can also result in increased length of stay and significant cost implications. Our objective was to reduce deep infection rates following spinal deformity surgery.

Method:

All paediatric patients undergoing spinal deformity procedures between 2008 and 2010 (group 1) were prospectively followed up and deep infection rates recorded. In 2010, a review of infection rates necessitated a change in pre-operative, peri-operative, and post-operative practice. A scoliosis wound care pathway was implemented, which involved insertion of drains to protect wounds, strict dressing management performed by a Spinal Nurse Practitioner, and a telephone helpline for concerns about wound care and general peri-operative scoliosis care. The use of betadine wash and local antibiotic application intra-operatively were other measures instigated later in this period. All paediatric patients undergoing surgery between 2011 and 2012 (group 2) were then followed up and differences in infection rates between the two groups were analysed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 183 - 183
1 Jan 2013
Torrie A Stenning M Wynne-Jones G Hutchinson J Nelson I
Full Access

Objective

Pyogenic spinal infection (PSI) is an increasingly common presentation to spinal units in the UK. Its investigation and diagnosis is often delayed. The purpose of this study was to determine the prognostic significance of the inflammatory marker levels on admission on achieving a positive microbiological diagnosis in patients with PSI.

Study design

Retrospective case series review of all patients presenting with PSI to our unit.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 46 - 46
1 Sep 2012
Morris S Loveridge J Torrie A Smart D Baker R Ward A Chesser T
Full Access

Aim

Evaluate the outcome and complications of anterior pubic symphysis plating in the stabilisation of traumatic anterior pelvic ring injuries.

Methods

All patients who underwent pubic symphysis plating in a tertiary referral unit were studied. Fracture classification, type of fixation, complications, and incidence of metalwork failure were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 9 - 9
1 Jul 2012
Stenning M Issac A Torrie A Hutchinson J Hutchinson J
Full Access

Objective

The purpose of this study is to describe and validate a CT based classification of lumbosacral segment abnormalities.

Method

400 CT scans were retrospectively reviewed, a classification devised and incidence of abnormalities recorded. 5 types of abnormality were identified. Type 0 is normal; Type 1 describes an asymmetrical shortening of the iliolumbar ligament; Type 2's have the transverse process of L5 within 2 mm of the sacrum but not forming a joint; Type 3's have formed a diarthrodial joint, with 3A's showing no evidence of degeneration and 3B's displaying degenerative changes; In type 4's the transverse process and sacrum have fused; Type5's have involvement of L4. In order to validate the classification, 40 scans were selected with a full cross section of types. 4 independent observers classified each scan in 2 separate sessions, 2 weeks apart.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIX | Pages 10 - 10
1 May 2012
Morris S Loveridge J Torrie A Smart D Baker R Ward A Chesser T
Full Access

There is controversy regarding the optimum method of stabilising traumatic anterior pelvic ring injuries. This study aimed to evaluate the role of pubic symphysis plating.

Methods

All patients who underwent pubic symphysis plating in a regional pelvic and acetabular unit were studied. Fracture classification, type of fixation, complications, and incidence of metalwork failure were recorded.

Results

Out of 178 consecutive patients, 159 (89%) were studied for a mean of 37.6 months. There were 121 males and 38 females (mean age 43 years). Symphysis pubic fixation was performed in 100 AO-OTA type B and 59 type C injuries using a Matta symphyseal plate (n=92), reconstruction plate (n=65), or DCP (n=2). Supplementary posterior pelvic fixation was performed in 102 patients. 5 patients required revision for failure of fixation or symptomatic instability of the pubic symphysis. A further 7 patients had metalwork removed for other reasons. Metalwork breakage occurred in 63 patients (40%). 62 of these 63 patients were asymptomatic and metalwork was left in situ.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 553 - 553
1 Oct 2010
Mcgrath A Iain S Katevu K Torrie A
Full Access

Hip fracture is a common serious injury in the elderly. Between 1982 and 1998 the number of hip fractures reported annually in Scotland in patients over 55 years rose from 4,000 to 5,700. The optimum method of treatment for the various fracture types remains in contention.

We compare outcome measures between displaced, intracapsular fractures in patients over 70 years fixed with cannulated screws and sliding hip screw with side plate.

Between 1998 and 2005 a total of 30,482 patients were reviewed by the Scottish Hip Fracture Audit (SHFA). Of these 15,823(53.3% of the total) had sustained intracapsular fractures. 13,587 of these occurred in patients aged 70 or over. Of these 2,428 had undisplaced and 11,159 displaced fractures. Chi test statistical analysis compare outcome measures in this group of displaced intracapsular fractures with respect to aspects of early failure.

534(3.9%) of patients were treated conservatively. 509 (4.7%) fractures were fixed using cannulated screws and 499 (4.6%) using a sliding hip screw. Readmission within 120 days for any cause occurred in 62 patients(14.1%) treated with cannulated screw fixation and in 63 patients(15.7%) for those treated with a sliding hip screw(P=0.509). Of these 36 patients(8.2%) in the former and 23 patients(5.7%) in the latter group were readmitted for complications related to hip fracture(P=0.033). Mortality within this period included 69 patients(13.5%) in the CS and 98(19.6%) in the SHS group. In terms of re-operation within 120 days of the original admission, 53 patients(10.6%) receiving cannulated screws compared to 24 patients(4.8%) treated with a sliding hip screw requiring further surgery(P=0.0006). The fracture was seen to displace in 12(22.6%) patients originally treated with cannulated screws compared to 6 patients(25%) treated with sliding hip screw(P=0.156). More significantly the fixation device was seen to have migrated in 24(45.3%) of the cannulated screw as compared to 7(29.2%) patients in the sliding hip screw group(P=0.002). Periprosthetic fractures were recorded in 4(7.5%) of the former and 3(12.5%) in the latter group(P=0.708). Wound infection was higher in the SHS group(2 patients) as compared to the screw fixation group(1 patient)(P=0.565).

Statistical analysis demonstrates a dramatic difference exists between these 2 fixation types in terms of re-operation within 120 days of the original admission for which published literature has previously only recorded biomechanical, in vitro comparisons.

Data regarding specific implant factors such as number of screws, position, configuration, starting point, thread length and use of washers in cannulated screws, and position, tapping, supplementary screw and compression screw in sliding hip screws was not recorded and may be considered to bias our results.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 553 - 554
1 Oct 2010
McGrath A Bartlett W Kalson N Katevu K Lee R McFadyen I Sewell M Torrie A
Full Access

For any fracture classification, a high level of intraobserver reproducibility and interobserver reliability is desirable. We compare the consistency of the AO and Neer classifications for proximal humerus fractures with an assessment of the digitised radiographs of 100 fractures by 10 orthopaedic surgeons and 5 radiologists using the General Electric Picture Archiving and Communications System (PACS), allowing manipulation of the image. This process repeated 1 month later.

Reproducibility and reliability moderate for both the AO and Neer systems. Reproducibility using the AO/ ASIF system was slightly greater. The assessor’s level of experience and specialty did affect accuracy. The ability to electronically manipulate images does not improve reliability and their sole use in describing these injuries and comparing similarly classified fractures from different centres is not recommended.

Fractures of the proximal humerus are common. Most undisplaced or minimally displaced, and treated conservatively. Up to one fifth may benefit from surgery. As decisions regarding treatment are based on the fracture type, a radiological classification should be easy to use and have a high degree of reliability and reproducibility to serve as a useful discriminator, creating standards by which treatment can be recommended and outcomes compared.

Radiographs of 100 fractures of the proximal humerus selected. A true anteroposterior, scapular lateral, and axillary radiograph taken for each fracture. 10 orthopaedic surgeons and 5 radiologists recruited as assessors, including 5 specialist registrars. Each given a printed description of both Neer and AO classifications, a goniometer and ruler. The assessment preceeded by short lecture. Radiographs could be manipulated digitally for size, contrast, brightness, orientation and the negative image displayed. We did not require assessors to determine subgroups for reasons of simplicity. Reproducibility and reliability analysed using Kappa statistical methods. Coefficients for agreement compared using the Student t test incorporating the standard errors of kappa for these groups. A comparison made between radiologists and surgeons, and then consultant orthopaedic surgeons and trainees.

In each case the AO/ASIF system was statistically (p< 0.01) more accurate.

Agreement was greater for less complex (one and two part, and type A) fractures.

Level of experience produced a statistically (p< 0.01) significant difference in accuracy. Specialty did not.

Our analysis comparing the Neer and AO systems uses the largest group of assessors reviewing the largest number of radiographs reported in the literature.

We concur with others in concluding that using these systems in isolation in determining treatment and comparing results following treatment cannot be recommended