header advert
Results 1 - 7 of 7
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 7 | Pages 924 - 928
1 Jul 2008
Tsuchiya H Shirai T Morsy AF Sakayama K Wada T Kusuzaki K Sugita T Tomita K

We studied the safety of external fixation during post-operative chemotherapy in 28 patients who had undergone distraction osteogenesis (17, group A) or vascularised fibular grafting (11, group B) after resection of a tumour. Four cycles of multi-agent post-operative chemotherapy were administered over a mean period of 14 weeks (6 to 27). The mean duration of external fixation for all patients was 350 days (91 to 828). In total 204 wires and 240 half pins were used.

During the period of post-operative chemotherapy, 14 patients (11 in group A, 3 in group B) developed wire- and pin-track infection. A total of ten wires (4.9%) and 11 half pins (4.6%) became infected. Seven of the ten infected wires were in periarticular locations.

External fixation during post-operative chemotherapy was used safely and successfully for fixation of a vascularised fibular graft and distraction osteogenesis in 27 of 28 patients. Post-operative chemotherapy for malignant bone tumours did not adversely affect the ability to achieve union or cause hypertrophy of the vascularised fibular graft and had a minimal effect on distraction osteogenesis. Only one patient developed osteomyelitis which required further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1077 - 1083
1 Aug 2007
Tsuchiya H Morsy AF Matsubara H Watanabe K Abdel-Wanis ME Tomita K

We present a retrospective study of patients suffering from a variety of benign tumours in whom external fixators were used to treat deformity and limb-length discrepancy, and for the reconstruction of bone defects. A total of 43 limbs in 31 patients (12 male and 19 female) with a mean age of 14 years (2 to 54) were treated.

The diagnosis was Ollier’s disease in 12 limbs, fibrous dysplasia in 11, osteochondroma in eight, giant cell tumour in five, osteofibrous dysplasia in five and non-ossifying fibroma in two. The lesions were treated in the tibia in 19 limbs, in the femur in 16, and in the forearm in eight. The Ilizarov frame was used in 25 limbs, the Taylor Spatial Frame in seven, the Orthofix fixator in six, the Monotube in four and the Heidelberg fixator in one. The mean follow-up was 72 months (22 to 221).

The mean external fixation period was 168 days (71 to 352). The mean external fixation index was 42 days/cm (22.2 to 102.0) in the 22 patients who required limb lengthening. The mean correction angle for those with angular deformity was 23° (7° to 45°).

At final follow-up all patients had returned to normal activities. Four patients required a second operation for recurrent deformity of further limb lengthening. Local recurrence occurred in one patient, requiring further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 218 - 225
1 Feb 2005
Tsuchiya H Wan SL Sakayama K Yamamoto N Nishida H Tomita K

We describe a method of reconstruction using tumour-bearing autograft treated by liquid nitrogen in 28 patients. The operative technique consisted of en bloc excision of the tumour, removal of soft tissue, curettage of the tumour, drilling and preparation for internal fixation or prosthetic replacement before incubation for 20 minutes in liquid nitrogen, thawing at room temperature for 15 minutes, thawing in distilled water for ten minutes, and internal fixation with an intramedullary nail, plate or composite use of prosthetic replacement. Bone graft or cement was used to augment bone strength when necessary.

The limb function was rated as excellent in 20 patients (71.4%), good in three (10.7%), fair in three (10.7%), and poor in two (7.1%). At the final follow-up six patients had died at a mean of 19.8 months after the operation, while 21 remained free from disease with a mean follow-up of 28.1 months (10 to 54). One patient is alive with disease. Bony union was seen at a mean of 6.7 months after the operation in 26 patients. Complications were encountered in seven patients, including three deep infections, two fractures, and two local recurrences. All were managed successfully. Our results suggest that this is a simple and effective method of biological reconstruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 8 | Pages 1162 - 1166
1 Nov 2002
Tsuchiya H Abdel-Wanis ME Sakurakichi K Yamashiro T Tomita K

In 11 patients juxta-articular osteosarcoma around the knee was treated by intraepiphyseal excision of the tumour and reconstruction of the bone defect by distraction osteogenesis. Preoperative and postoperative chemotherapy was given to eight patients with high-grade tumours. The articular cartilage of the epiphysis and a maximum of healthy soft tissues were preserved. Distraction osteogenesis was then carried out.

The mean gain in length was 9.7 cm. Full function of the limb was preserved in all except one patient, with a mean follow-up of 53.8 months. Treatment of juxta-articular osteosarcomas around the knee with joint preservation and biological reconstruction using distraction osteogenesis can give excellent functional results.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 2 | Pages 245 - 248
1 Mar 2002
Tsuchiya H Abdel-Wanis ME Uehara K Tomita K Takagi Y Yasutake H

We describe a consecutive series of 26 patients with simple bone cysts who were treated by curettage, multiple drilling and continuous decompression by the insertion of either a cannulated screw or a pin. In the first 15 patients we used titanium cannulated screws (group 1) and in the next 11 a cannulated hydroxyapatite pin (group 2). Satisfactory healing was achieved in 12 patients in group 1 (80%) and in all in group 2. This technique seems to be a promising option for the treatment of simple bone cysts. The cannulated hydroxyapatite pin is recommended because of its higher success rate and the fact that it does not need to be removed.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 3 | Pages 403 - 411
1 May 1997
Tsuchiya H Tomita K Minematsu K Mori Y Asada N Kitano S

We report the results of distraction osteogenesis (callotasis) for the reconstruction of extensive defects after the excision of skeletal tumours in the limbs. Bone transport was performed in ten patients (five osteosarcomas and five giant-cell tumours), shortening-distraction in three (two osteosarcomas and one Ewing’s sarcoma), and distraction osteogenesis combined with an intramedullary nail to reduce the time of external fixation in six (three osteosarcomas, two chondro-sarcomas, and one malignant fibrous histiocytoma).

The mean length of the defects after excision of the lesion was 8.4 cm. The mean external fixation index was 39.5 days/cm for the group treated by bone transport, 34.1 days/cm for the shortening-distraction group, and 24.0 days/cm for the group treated by distraction and an intramedullary nail. Functional evaluation gave excellent results in 12 patients, good in five and fair in two. There were ten complications in 19 patients, all of which were successfully treated.

We also classified reconstruction using distraction osteogenesis into five types based on the location of the defects after resection of the tumour: type 1, diaphyseal; type 2, metaphyseal; type 3, epiphyseal; type 4, subarticular reconstruction; and type 5, arthrodesis.

Our results suggest that reconstruction using distraction osteogenesis provides bone which will develop sufficient biomechanical strength and durability. It is beneficial in patients with an expectation of long-term survival and in growing children.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 264 - 269
1 Mar 1996
Tsuchiya H Tomita K Shinokawa Y Minematsu K Katsuo S Taki J

We have used the Ilizarov technique for the management of subarticular defects after the excision of giant-cell tumours in the proximal tibia in five patients. The defect was reconstructed with a segment of 5 to 6 cm obtained from the diaphysis of the affected tibia and by autogenous bone graft from the iliac crest. The newly developed defect in the diaphysis was reconstructed by distraction using the Ilizarov apparatus. Bone grafting at the docking site was performed soon after positioning the bone segments.

The mean length of the bone defect was 5.7 cm and the mean duration of external fixation was 233 days. The relative blood flow in the leg measured by 99mTc angiography increased by 1.7 to 2.3 times that of the control level during distraction and consolidation. When seen at a mean of 43 months all patients showed a normal range of motion in the knee and ankle with no collapse of the articular surfaces.