header advert
Results 1 - 20 of 77
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 22 - 22
2 May 2024
Logishetty K Whitwell D Palmer A Gundle R Gibbons M Taylor A Kendrick B
Full Access

There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up.

This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA, implant survivorship, clinical outcomes, and indications for re-operation.

A total of 39 TFAs were performed in 38 patients between 2015–2018 (median age 68 years, IQR 17, range 46–86), with 5.3 years’ (IQR 1.2, 4.1–18.8) follow-up; 3 patients had died. The most common indication (30/39, 77%) for TFA was periprosthetic joint infection (PJI) or fracture-related infection (FRI); and 23/39 (59%) had a prior periprosthetic fracture (PPF). TFA was performed with dual-mobility or constrained cups in 31/39 (79%) patients. Within the cohort, 12 TFAs (31%) required subsequent revision surgery: infection (7 TFAs, 18%) and instability (5 TFAs, 13%) were the most common indications. 90% of patients were ambulatory post-TFA; 2 patients required disarticulation due to recurrent PJI. While 31/39 (79%) were infection free at last follow-up, the remainder required long-term suppressive antibiotics.

This is the largest series of TFA for non-oncological indications. Though TFA has inherent risks of instability and infection, most patients are ambulant after surgery. Patients should be counselled on the risk of life-long antibiotics, or disarticulation when TFA fails.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 59 - 59
24 Nov 2023
McCulloch R Martin A Kendrick B Jeys L Alvand A Young B Taylor A Stevenson J Palmer A
Full Access

Introduction

A proportion of patients with hip and knee prosthetic joint infection (PJI) undergo multiple revisions with the aim of eradicating infection and improving quality of life. The aim of this study was to describe the microbiology cultured from multiply revised hip and knee replacement procedures to guide antimicrobial therapy at the time of surgery.

Patients and Methods

Consecutive patients were retrospectively identified from databases at two specialist orthopaedic centres in the United Kingdom between 2011 and 2019. Patient were included who had undergone repeat revision total knee replacement (TKR) or total hip replacement (THR) for infection, following an initial failed revision for infection.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 32 - 32
7 Jun 2023
Howgate D Roberts PG Palmer A Price A Taylor A Rees J Kendrick B
Full Access

Primary total hip replacement (THR) is a successful and common operation which orthopaedic trainees must demonstrate competence in prior to completion of training. This study aimed to determine the impact of operating surgeon grade and level of supervision on the incidence of 1-year patient mortality and all-cause revision following elective primary THR in a large UK training centre.

National Joint Registry (NJR) data for all elective primary THR performed in a single University Teaching Hospital from 2005–2020 were used, with analysis performed on the 15-year dataset divided into 5-year temporal periods (B1 2005–2010, B2 2010–2015, B3 2015–2020). Outcome measures were mortality and revision surgery at one year, in relation to lead surgeon grade, and level of supervision for trainee-led operations.

9999 eligible primary THR were undertaken, of which 5526 (55.3%) were consultant led (CL), and 4473 (44.7%) trainees led (TL). Of TL, 2404 (53.7%) were non-consultant supervised (TU), and 2069 (46.3%) consultant supervised (TS). The incidence of 1-year patient mortality was 2.05% (n=205), and all-cause revision was 1.11% (n=111). There was no difference in 1-year mortality between TL (n=82, 1.8%) and CL (n=123, 2.2%) operations (p=0.20, OR 0.78, CI 0.55–1.10). The incidence of 1-year revision was not different for TL (n=56, 1.3%) and CL (n=55, 1.0%) operations (p=0.15, OR 1.37, CI 0.89–2.09). Overall, there was no temporal change for either outcome measure between TL or CL operations. A significant increase in revision within 1-year was observed in B3 between TU (n=17, 2.7%) compared to CL (n=17, 1.0%) operations (p=0.005, OR 2.81, CI 1.35–5.87).

We found no difference in 1-year mortality or 1-year all-cause revision rate between trainee-led primary THR and consultant-led operations over the entire fifteen-year period. However, unsupervised trainee led THR in the most recent 5-year block (2015–2020) has a significantly increased risk of early revision, mainly due to instability and prosthetic joint infection. This suggests that modern surgical training is having a detrimental effect on THR patient outcomes. More research is needed to understand the reasons if this trend is to be reversed.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 19 - 19
1 Oct 2022
Schenk HM Sebillotte M Lomas J Taylor A Benavent E Murillo O Fernandez-Sampedro M Huotari K Aboltins C Trebse R Soriano A Wouthuyzen-Bakker M
Full Access

Aim

Patients with late acute periprosthetic joint infections (PJI) and treated with surgical debridement have a high failure rate. Previous studies have shown that rheumatoid arthritis (RA) is an independent risk factor for treatment failure. We conducted a case-control study to identify predictors for failure in late acute PJI treatment in RA patients. We hypothesize that patients with RA have a higher failure rate compared to controls due to the use of immunosuppressive drugs.

Method

Data of an international multicenter retrospective observational study was used. Late acute PJI was defined as a sudden onset of symptoms and signs of a PJI, more than 3 months after implantation. Failure of treatment was defined as persistent signs of infection, relapse with the same or reinfection with a different micro-organism, need for prosthesis removal or death. Cases with RA were matched with cases without RA based on the affected joint. A Cox survival analyses, stratified for RA, was used to calculate hazard ratio's (HR) for failure. Subgroup analyses were used to explore other predictors for treatment failure in RA patients.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 37 - 37
1 Jul 2022
McCulloch R Palmer A Donaldson J Kendrick B Warren S Atkins B Alvand A Carrington R Taylor A Miles J
Full Access

Abstract

Aims

The primary aim of this study was to evaluate the outcomes of fungal knee periprosthetic joint infection following knee arthroplasty. The secondary aim was to evaluate risk factors for acquiring a fungal PJI.

Patients and Methods

This was a retrospective analysis of patients presenting with a confirmed fungal PJI of the knee in two tertiary centres. There were a total of 45 cases. Isolated fungal infections along with mixed bacterial and fungal infections were included. Mean follow up was 40 months (range 3–118).


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 729 - 735
1 Jun 2022
Craxford S Marson BA Nightingale J Forward DP Taylor A Ollivere B

Aims

The last decade has seen a marked increase in surgical rib fracture fixation (SRF). The evidence to support this comes largely from retrospective cohorts, and adjusting for the effect of other injuries sustained at the same time is challenging. This study aims to assess the impact of SRF after blunt chest trauma using national prospective registry data, while controlling for other comorbidities and injuries.

Methods

A ten-year extract from the Trauma Audit and Research Network formed the study sample. Patients who underwent SRF were compared with those who received supportive care alone. The analysis was performed first for the entire eligible cohort, and then for patients with a serious (thoracic Abbreviated Injury Scale (AIS) ≥ 3) or minor (thoracic AIS < 3) chest injury without significant polytrauma. Multivariable logistic regression was performed to identify predictors of mortality. Kaplan-Meier estimators and multivariable Cox regression were performed to adjust for the effects of concomitant injuries and other comorbidities. Outcomes assessed were 30-day mortality, length of stay (LoS), and need for tracheostomy.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 22 - 22
1 Apr 2022
France J Tucker A Norrish A Taylor A Ollivere B
Full Access

Introduction

The use of the Taylor Spatial Frame (TSF) in the management of tibial fractures and deformity correction is well established in the literature, however the majority of published papers are small in patient number. The aim of the project was to evaluate clinical and radiographic outcomes of patients with tibial fractures treated with a TSF.

Materials and Methods

A retrospective analysis of patient records and radiographs was performed to obtain patient data, information on injury sustained, the operative technique used, frame construct, time duration in frame, union rates and complications of treatment.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 84 - 84
1 Dec 2021
Hotchen A Wismayer M Robertson-Waters E McDonnell S Kendrick B Taylor A Alvand A McNally M
Full Access

Aim

This study assesses the ability of the JS-BACH classification of bone infection to predict clinical and patient-reported outcomes in prosthetic joint infection (PJI).

Method

Patients who received surgery for suspected PJI at two specialist bone infection centres within the UK between 2010 and 2015 were classified using the JS-BACH classification into either ‘uncomplicated’, ‘complex’ or ‘limited options’. All patients were classified by two clinicians blinded to outcome, with any discrepancies adjudicated by a third reviewer. At the most recent follow-up, patients were assessed for (i) any episode of recurrence since the index operation and (ii) the status of the joint. A Cox proportional-hazard model assessed significant predictors of recurrence following the index procedure. Patient-reported outcomes included the EuroQol EQ-5D-3L index score and the EQ-visual analogue score (VAS) at 0, 14, 42, 120 and 365 days following the index operation.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 31 - 31
1 Aug 2021
Ahmed B George D El Ashmawy A Minhas Z Palmer A Taylor A Kendrick B
Full Access

Treatment of periprosthetic joint infection (PJI) can include local delivery of antibiotics. A frequently used medium is absorbable calcium sulphate beads. The aims of this study were to:

identify how often organisms in infected THRs are sensitive to the added antibiotics

establish the incidence of persistent wound discharge and hypercalcaemia

All patients who received an antibiotic loaded calcium sulphate carrier (Stimulan, Biocomposites, Keele, UK) for either confirmed infection, presumed infection or for prophylaxis between July 2015 and July 2020 were included. Stimulan use was at the discretion of the surgeon, and between 10 and 40cc was used. In the absence of a known organism we routinely used 1g vancomycin and 240mg gentamicin per 10 cc of calcium sulphate. Post-operative sensitivities for all organisms cultured were compared to the antibiotics delivered locally. Persistent wound drainage was defined as discharge beyond the third postoperative day. Patients had serum calcium measured if they developed symptoms consistent with hypercalcaemia (Ca >2.6 mmol/L) or the clinical team felt they were at high risk.

189 patients (mean age 66.9 years, mean BMI 28.9, 85 male, 104 female) were included. 11 patients had a native joint septic arthritis, 42 presented with acute PJI and 136 presented with chronic PJI. 133 patients grew an organism, of which 126 were sensitive to the added antibiotics. Of the seven patients with resistant growth five had vancomycin-resistent Enterococcus, one Pseudomonas and one multi-organism growth including coagulase negative Staphylococcus. 40 patients experienced persistent wound discharge, with eight requiring re-operation. All other cases settled with dressing management. 12 patients developed hypercalcaemia (3/64 10cc, 7/117 20cc, 0/2 30cc and 2/6 40cc). The peak calcium reading ranged between the second and twelfth post-operative day.

The addition of vancomycin and gentamicin to absorbable calcium sulphate covers the majority of organisms found in culture positive infection in our cohort. It also appears safe, with an acceptable incidence of hypercalcaemia or wound discharge. Further work is required to identify patients at greatest risk of culturing resistant organisms or delayed wound healing.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1173 - 1173
1 Jun 2021
Alsousou J Oragui E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 644 - 649
1 Apr 2021
Alsousou J Oragu E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA).

Methods

A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 25 - 25
1 Feb 2020
De Villiers D Collins S Taylor A Dickinson A
Full Access

INTRODUCTION

Hip resurfacing offers a more bone conserving solution than total hip replacement (THR) but currently has limited clinical indications related to some poor design concepts and metal ion related issues. Other materials are currently being investigated based on their successful clinical history in THR such as Zirconia Toughened Alumina (ZTA, Biolox Delta, CeramTec, Germany) which has shown low wear rates and good biocompatibility but has previously only been used as a bearing surface in THR. A newly developed direct cementless fixation all-ceramic (ZTA) resurfacing cup offers a new solution for resurfacing however ZTA has a Young's modulus approximately 1.6 times greater than CoCr - such may affect the acetabular bone remodelling. This modelling study investigates whether increased stress shielding may occur when compared to a CoCr resurfacing implant with successful known clinical survivorship.

METHODS

A finite element model of a hemipelvis constructed from CT scans was used and virtually reamed to a diameter of 58mm. Simulations were conducted and comparisons made of the ‘intact’ acetabulum and ‘as implanted’ with monobloc cups made from CoCr (Adept®, MatOrtho Ltd, UK) and ZTA (ReCerf ™, MatOrtho Ltd. UK) orientated at 35° inclination and 20° anteversion. The cups were loaded with 3.97kN representing a walking load of 280% for an upper bound height patient with a BMI of 35. The cup-bone interface was assigned a coulomb slip-stick function with a coefficient of friction of 0.5. The percentage change in strain energy density between the intact and implanted states was used to indicate hypertrophy (increase in density) or stress shielding (decrease in density).


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2019
Minhas Z Palmer A Alvand A Taylor A Kendrick B
Full Access

Introduction

Antibiotic loaded absorbable calcium sulphate beads (ALCSB) are an increasingly popular adjunct in the treatment of musculoskeletal infections including osteomyelitis and peri-prosthetic joint infections (PJI). Limited data exist regarding the clinical indications and biochemical outcomes of ALCSB in PJI cases.

Aims

To determine the proportion of organisms that were sensitive to the gentamicin and vancomycin that we add to the ALCSB as a part of our treatment protocol and to determine the prevalence of postoperative hypercalcaemia when used for treatment of hip and knee DAIR (debridement and implant retention) and revision arthroplasty for PJI.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 40 - 40
1 May 2019
Vanhegan I Martin A Gundle R Taylor A Kendrick B
Full Access

Introduction

We are a high-volume arthroplasty unit performing over 800 primary THRs annually at an approximate reimbursement of £6.5 million to the Trust. 70% are hybrid and we have been using the Taperfit - Trinity combination (Corin, Cirencester) since March 2016. We aimed to investigate the potential cost-savings and clinical benefits of instrument rationalisation using this system following GIRFT principles.

Methods

Taperfit (ODEP 10A) is a polished, collarless, double tapered stem available in multiple sizes/offsets. Trinity is a hemispherical porous titanium cementless shell. A prospective audit of implant size was performed for the first 50 cases. Based on these findings, instruments were reduced to a single tray per component based on predicted size, named ‘Corin Hip for the Osteoarthritic Patient’ (CHOP). A further re-audit was performed to confirm correct tray constituent sizes. Financial data were calculated using known TSSU costs of approximately £50 per tray.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 11 - 11
1 May 2019
Jordan S Taylor A Jhaj J Akehurst H Ivory J Ashmore A Rigby M Brooks R
Full Access

Background

Total hip arthroplasty (THA) is increasingly used for active patients with displaced intracapsular hip fractures. Dislocation rates in this cohort remain high postoperatively compared to elective practice, yet it remains unclear which patients are most at risk. The aim of this study was to determine the dislocation rate for these patients and to evaluate the contributing patient and surgeon factors.

Methods

A five-year retrospective analysis of all patients receiving THA for displaced intracapsular hip fractures from 2013–18 was performed. Data was collected from the institutions' hip fracture database, including data submitted to the National Hip Fracture Database (NHFD). Cox regression analysis and log-rank tests were implemented to evaluate factors associated with THA dislocation. Patient age, sex, ASA grade, surgeon seniority, surgical approach, femoral head diameter and acetabular cup type were all investigated as independent factors.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 93 - 93
1 Apr 2019
Avila C Taylor A Collins S
Full Access

INTRODUCTION

Unlike current acetabular cups, this novel ceramic cup has a Ti/HA coating which removes the requirement for assembly into a metal shell which avoiding potential chipping/misalignment and reducing wall thickness [Figure 1]. This study examines the resistance of novel thin-walled, direct to bone fixation ceramic cups to critical impact loads.

METHODS

Samples of the smallest (Ø46mm) and largest (Ø70mm) diameter ReCerfTM acetabular cups and corresponding femoral head implants were implanted into Sawbones foam blocks considered representative of pelvic cancellous bone. Two different positional configurations were tested and were considered worst case and the extremes of surgical compromise; P1 simulates the cup fully supported by the acetabulum with a high inclination angle (70°) and a vertical impaction axis (worst case loading near the cup rim) and. P2 simulates the cup implanted with a lower inclination (55°) but with the superior section unsupported by acetabulum bone [Figure 2]. For each size, three acetabular cups were tested in each position. The impact fixture was positioned within a drop weight rig above a bed of sand and ≈22mm of pork belly representative of soft tissues damping effect and the implant components aligned to achieve the defined impact point on the cup [Figure 2]. Lateral falls were tested on all available samples applying impact energy of 140J [1] and 3m/s impact velocity [2]. After the lateral fall test, each sample was tested under impact conditions equivalent to a frontal car crash considering a peak impact force of 5.7kN occurring 40ms from initial contact (able to produce acetabular fracture)[3].


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 21 - 21
1 Dec 2018
Harrison C Alvand A Chan J West E Matthews P Taylor A Giele H McNally M Ramsden A
Full Access

Aim

A number of orthopaedic strategies have been described for limb salvage following periprosethic joint infection (PJI). However, this is often only possible with concomitant soft tissue reconstruction in the form of flap coverage. The purpose of this study was to determine the long-term clinical outcome of patients who underwent pedicled gastrocnemius flap coverage as part of their treatment for knee PJI.

Method

We performed a retrospective review of all patients undergoing gastrocnemius muscle transfer with split thickness skin grafting as part of their treatment for knee PJI at a tertiary referral centre between 1994 and 2015. Data recorded included patient characteristics, orthopaedic procedure, microbiology result and antimicrobial management. Outcome measures included flap failure, infection recurrence, amputation, functional outcome (Oxford knee score; OKS) and mortality.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 92 - 92
1 Dec 2018
Wouthuyzen-Bakker M Sebillotte M Lomas J Taylor A Palomares EB Murillo O Parvizi J Shohat N Reinoso JC Sánchez RE Fernandez-Sampedro M Senneville E Huotari K Allende JB Garcia-Cañete J Lora-Tamayo J Ferrari MC Vaznaisiene D Yusuf E Aboltins C Trebse R Salles M Benito N Vila A Del Toro MD Kramer T Petershof S Diaz-Brito V Tufan ZK Sanchez M Arvieux C Soriano A
Full Access

Aim

Debridement, antibiotics and implant retention (DAIR) is the recommended treatment for all acute prosthetic joint infections (PJI). However, the efficacy of DAIR and identification of risk factors for failure in patients with late acute PJI, is not well described.

Method

Patients diagnosed with late acute PJI between 2005 and 2015 were retrospectively evaluated. Late acute PJI was defined as the development of acute symptoms (≤ 3 weeks) occurring ≥ 3 months after arthroplasty. Failure was defined as: i) the need for implant removal, ii) infection related death, iii) the need for suppressive antibiotic therapy due to persistent signs of infection and/or iv) relapse or reinfection during follow-up.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1148 - 1156
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this study was to determine the stability of a new short femoral stem compared with a conventional femoral stem in patients undergoing cementless total hip arthroplasty (THA), in a prospective randomized controlled trial using radiostereometric analysis (RSA).

Patients and Methods

A total of 53 patients were randomized to receive cementless THA with either a short femoral stem (MiniHip, 26 patients, mean age: 52 years, nine male) or a conventional length femoral stem (MetaFix, 23 patients, mean age: 53 years, 11 male). All patients received the same cementless acetabular component. Two-year follow-up was available on 38 patients. Stability was assessed through migration and dynamically inducible micromotion. Radiographs for RSA were taken postoperatively and at three, six, 12, 18, and 24 months.


The Bone & Joint Journal
Vol. 100-B, Issue 9 | Pages 1146 - 1147
1 Sep 2018
Ferguson RJ Broomfield JA Malak TT Palmer AJR Whitwell D Kendrick B Taylor A Glyn-Jones S