Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 538 - 538
1 Dec 2013
Stein M
Full Access

Smart instrumentation targets optimal joint hardware installation. Intelligent implants target the chronic assessment of joint health and hardware condition.

Intelligent implants would facilitate the collection of data, closing the loop to drive best surgical practice, joint system design, and the improvement of outcomes. Intelligent devices could assist post-op in managing pain and promoting recovery. Intelligent implants could offer opportunity for early detection and less invasive intervention should problems arise acutely, or even long after implant.

While the development of smart instrumentation is tactically important, the development of intelligent implants is vital to the improvement of outcomes, and should be central to the strategic vision for orthopedic technology development.

KEY DISCUSSION POINTS

Define “smart” instruments in orthopedics and why there is a need for developing these devices to achieve optimal joint hardware installation.

Define “intelligent” implants in orthopedics and why there is a need for developing these devices to facilitate the collection of data, and thereby “closing the loop” with smart instrumentation to drive best surgical practice and joint system design.

Review clinical benefits of intelligent implants in post-operation pain management and recovery, as well as early problem detection facilitating less invasive intervention both acutely and chronically.

Understand the latest advances in sensors and related technologies for orthopedic implants and implementing best practices for their use in medical design.

Describe the reduction to practice of an intelligent implant tray capable of measuring and monitoring load, position, and the early onset of infection, and capable of delivering neuro-stimulation for pain management.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 39 - 39
1 Mar 2010
Vitale MG Marangoz S Gomez JA van Bosse HJP Hyman JE Feldman DS Sala DA Stein M
Full Access

Purpose: Use of six-axis analysis and computer assisted deformity correction via a circular external fixator is a new method for deformity correction. We investigated its accuracy and safety in reconstruction of femoral deformity in children and young adults.

Method: We retrospectively reviewed all cases including the indications for use and the methodology of application of the computer assisted six-axis analysis and circular external fixator for reconstruction of 22 femora in 20 patients. Twelve patients were female, and 8 were male. The average age was 13.9 (range, 5.9–24.6). Etiology included traumatic (7), idiopathic (6), multiple enchondromatosis (2), rickets (2), congenital femoral deficiency (2), spondyloepiphyseal dysplasia (1), congenital pseudohypoparathyroidisim (1), and multifocal osteomyelitis (1). Clinical and radiographic data were analyzed.

Results: Average follow-up was 14.4 months (range, 4.5–32). Average time in frame was 6.2 months (range, 2.6–19). Bone lengthening of 3.9 cm (range, 1–8.5) was performed in 12 femora. In genu valgum patients, the mLDFA improved from a mean of 73.7° to a mean of 89°. In genu varum patients, the mLDFA improved from a mean of 99.8° to a mean of 89.5°. Complications included pin tract infection in 6, knee stiffness in 3, delayed union in 2, skin irritation in 1, posterior knee subluxation in 2, both of which had stable knees preoperatively. One patient was lost to follow-up and returned back with deformity. No complications occurred in 8 patients.

Conclusion: Computer assisted femoral deformity correction with six-axis analysis and application of circular external fixator is a useful technique with the advantage of managing multiplanar deformities in children and young adults. It has the potential complications of the use of any external fixator. Close follow-up is necessary to avoid subluxation of the knee joint even in patients with stable knees. Accurate and safe correction can be achieved in almost all patients.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 11 - 11
1 Mar 2010
Roye DP Gomez J Vitale MG Hyman JE Matsumoto H Feldman D Marangoz S vanBosse HP Sala DA Stein M
Full Access

Purpose: To describe the clinical outcomes of adolescent patients, treated with hip distraction arthroplasty for avascular necrosis (AVN) of the femoral head. Outcomes were examined in order to better understand the usefulness and indications of performing hip arthrodia-stasis in this patient population.

Method: Retrospective review was performed on thirty-one hips with femoral head AVN treated with hip distraction arthroplasty. Mean age at treatment was 14.2 years. Preoperative and follow-up pain, and physical limitations, as well as follow-up range of motion (ROM) were assessed.

Results: Follow up assessment was obtained at 18.3 years of age. Time of follow up was 55.3 months after distraction. The etiologies of AVN were: 11 Slipped Capital Femoral Epyphysis (SCFE); 5 Idiopathic AVN; 3 with hip dysplasia; and 12 others. There was a significant difference in pain preoperatively and postoperatively (p< .001), the majority of patients (79.5%, n=23) had less pain after the treatment. Multivariate regression model demonstrated that patients with SCFE were likely to have less improvement in pain than patients with other etiologies (odds ratio: 24.8; p=.035). All patients had activity limitations before the treatment; at the postoperative assessment more than half of our patients (n=15) reported no limitations in their activities. Nine patients had minor complications with the fixator. At follow up, 5 (16.1 %) patients converted to total hip replacement or arthrodesis.

Conclusion: Hip distraction arthroplasty in adolescent patients with symptomatic AVN reduces the amount of pain and limitation in daily activities, at a follow up of 4.6 years. Arthrodiastasis is not the final solution to AVN, with longer follow up patient’s symptomatology increases. Patients with AVN secondary to SCFE do not beneficiate of this procedure as much as other patients do. Hip distraction is a safe and appropriate procedure to perform in these patients. The procedure might be able to delay definitive surgical procedures at an early age, restoring function and improving the patient s quality of life.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 326 - 329
1 Mar 1987
Giladi M Milgrom C Simkin A Stein M Kashtan H Margulies J Rand N Chisin R Steinberg R Aharonson Z et A

A prospective study of 295 infantry recruits has shown that the mediolateral width of the tibia measured radiographically at each of three different levels in the bone had a statistically significant correlation with the total incidence of stress fractures as well as with those in the tibia alone or the femur alone. A narrow tibial width was shown to be a risk factor, but cortical thickness was not found to be significant.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 3 | Pages 439 - 441
1 May 1986
Giladi M Milgrom C Kashtan H Stein M Chisin R Dizian R

Of 66 recruits who sustained stress fractures during basic training and returned to training after a period of rest, seven (10.6%) suffered recurrent fractures within one year. None of the recurrences was at the original anatomical site. All of the recruits with recurrent stress fractures had had at least one of their initial stress fractures in the femur. This suggests that a femoral stress fracture carries a high risk of recurrence at other sites.


The Journal of Bone & Joint Surgery British Volume
Vol. 67-B, Issue 5 | Pages 732 - 735
1 Nov 1985
Milgrom C Giladi M Stein M Kashtan H Margulies J Chisin R Steinberg R Aharonson Z

In a prospective study of 295 male Israeli military recruits a 31% incidence of stress fractures was found. Eighty per cent of the fractures were in the tibial or femoral shaft, while only 8% occurred in the tarsus and metatarsus. Sixty-nine per cent of the femoral stress fractures were asymptomatic, but only 8% of those in the tibia. Even asymptomatic stress fractures do, however, need to be treated. Possible explanations for the unusually high incidence of stress fractures in this study are discussed.