header advert
Results 1 - 20 of 53
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 112 - 112
11 Apr 2023
Oliver W Nicholson J Bell K Carter T White T Clement N Duckworth A Simpson H
Full Access

The primary aim was to assess the reliability of ultrasound in the assessment of humeral shaft fracture healing. The secondary aim was to estimate the accuracy of ultrasound assessment in predicting humeral shaft nonunion.

Twelve patients (mean age 54yrs [20–81], 58% [n=7/12] female) with a non-operatively managed humeral diaphyseal fracture were prospectively recruited and underwent ultrasound scanning at six and 12wks post-injury. Scans were reviewed by seven blinded observers to evaluate the presence of sonographic callus. Intra- and inter-observer reliability were determined using the weighted kappa and intraclass correlation coefficient (ICC). Accuracy of ultrasound assessment in nonunion prediction was estimated by comparing scans for patients that united (n=10/12) with those that developed a nonunion (n=2/12).

At both six and 12wks, sonographic callus was present in 11 patients (10 united, one developed a nonunion) and sonographic bridging callus (SBC) was present in seven patients (all united). Ultrasound assessment demonstrated substantial intra- (6wk kappa 0.75, 95% CI 0.47-1.03; 12wk kappa 0.75, 95% CI 0.46-1.04) and inter-observer reliability (6wk ICC 0.60, 95% CI 0.38-0.83; 12wk ICC 0.76, 95% CI 0.58-0.91). Absence of sonographic callus demonstrated a sensitivity of 50%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 91% in nonunion prediction (accuracy 92%). Absence of SBC demonstrated a sensitivity of 100%, specificity 70%, PPV 40% and NPV 100% (accuracy 75%). Of three patients at risk of nonunion based on reduced radiographic callus formation (Radiographic Union Score for HUmeral fractures <8), one had SBC on 6wk ultrasound (and united) and the other two had non-bridging or absent sonographic callus (both developed a nonunion).

Ultrasound assessment of humeral shaft fracture healing was reliable and predictive of nonunion, and may be a useful tool in defining the risk of nonunion among patients with reduced radiographic callus formation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 119 - 119
4 Apr 2023
Jalal M Wallace R Peault B Simpson H
Full Access

To test and evaluate the effectiveness of local injection of autologous fat-derived mesenchymal stem cells (MSCs) into fracture site to prevent non-union in a clinically relevant model.

5 male Wistar rats underwent the same surgical procedure of inducing non-union. A mid-shaft tibial osteotomy was made with 1mm non-critical gap. Periosteum was stripped around the two fracture ends. Then, the fracture was fixed by ante-grade intramedullary nail. The non-critical gap was maintained by a spacer with minimal effect on the healing surface area. At the same surgical time, subcutaneous fat was collected from the ipsilateral inguinal region and stem cells were isolated and cultured in vitro. Within three weeks postoperatively, the number of expanded stem cells reached 5×106 and were injected into the fracture site. Healing was followed up for 8 weeks and the quality was measured by serial x-rays, microCT, mechanical testing and histologically. Quality of healing was compared with that of previously published allogenic, xenogeneic MSCs and Purified Buffered Saline (PBS) controls.

All the five fractures united fully after 8 weeks. There was a progressive increase in the callus radiopacity during the eight-week duration, the average radiopacity in the autologous fat-MSC injected group was significantly higher than that of the allogeneic MSCs, xenogeneic MSCs and the control group, P < 0.0001 for treatment, time after injection, and treatment-time interaction (two-way repeated measure ANOVA). MicroCT, mechanical testing and histology confirmed radiological findings.

The autologous fat-MSCs are effective in prevention of atrophic non-union by stimulation of the healing process leading to a solid union. The quality and speed of repair are higher than those of the other types of cell transplantation tested.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 76 - 76
1 Oct 2022
Russell C Tsang SJ Dudareva M Simpson H Sutherland R McNally M
Full Access

Aim

Pelvic osteomyelitis following pressure ulceration results in substantial patient morbidity. Previous studies have reported a heterogenous approach to diagnosis and medical management by physicians, suggesting equipoise on key clinical questions. This study hypothesised that the same equipoise exists amongst Orthopaedic surgeons.

Method

An 18-question multiple-choice questionnaire was designed through an iterative feedback process until the final version was agreed by all authors. Likert-type scale responses were used with graded responses (e.g., never/fewer than half of patients/around half of patients/more than half of patients/every patient). The online survey was sent to members of the Musculoskeletal Infection Society (MSIS), the European Bone and Joint Infection Society (EBJIS), and the ESCMID Study Group for Implant-Associated Infections (ESGIAI). No incentive for participation was provided.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 28 - 28
1 Jul 2022
Yapp L Scott C Macdonald D Howie C Simpson H Clement N
Full Access

Abstract

INTRODUCTION

This study investigates whether primary knee arthroplasty (KA) restores health-related quality of life (HRQoL) to levels expected in the general population.

METHODOLOGY

This retrospective case-control study utilises two sources: patients undergoing primary KA from a University Teaching hospital; and individual-level data from the Health Survey for England which was used to represent the General Population.

Propensity score matching was used to balance covariates (sex, age and body mass index (BMI)) and facilitate group comparisons. Two matched cohorts with 3029 patients each were obtained for the adjusted analyses (median age 70.3 interquartile range (IQR) 64–77; Female sex 3233 (53.4%); median BMI 29.7 IQR 26.5-33.7). HRQoL was measured using the three-level version of the EuroQol 5-Dimensions’ (EQ-5D-3L) Index and EQ-VAS scores.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 19 - 19
1 Apr 2022
Tsang SJ Stirling P Simpson H
Full Access

Introduction

Distal femoral and proximal tibial osteotomies are effective procedures to treat degenerative disease of the knee joint. Previously described techniques advocate the use of bone graft to promote healing at the osteotomy site. In this present study a novel technique which utilises the osteogenic potential of the cambial periosteal layer to promote healing “from the outside in” is described.

Materials and Methods

A retrospective analysis of a consecutive single-surgeon series of 23 open wedge osteotomies around the knee was performed. The median age of the patients was 37 years (range 17–51 years). The aetiology of the deformities included primary genu valgum (8/23), fracture malunion (4/23), multiple epiphyseal dysplasia (4/23), genu varum (2/23), hypophosphataemic rickets (1/23), primary osteoarthritis (1/23), inflammatory arthropathy (1/23), post-polio syndrome (1/23), and pseudoachondroplasia (1/23).


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 19 - 19
1 Dec 2021
Brzeszczynski F Brzeszczynska J Murray I Duckworth A Simpson H Hamilton D
Full Access

Abstract

Objectives

Sarcopenia is characterised by generalised progressive loss of physical performance, skeletal muscle mass and strength. This systematic review evaluated the effects of sarcopenia on postoperative functional recovery outcomes and mortality in patients undergoing orthopaedic surgery and secondarily assessed the methods used to diagnose and define sarcopenia in orthopaedic literature.

Methods

A systematic search was conducted in MEDLINE, EMBASE and Google Scholar databases according to the PRISMA guidelines. Studies involving sarcopenic patients who underwent defined orthopaedic surgery and recorded postoperative outcomes were included. The quality of the criteria by which a sarcopenia diagnosis was made was evaluated and publication quality was assessed using Newcastle-Ottawa Scale.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 14 - 14
1 Mar 2021
Tsang J Gallagher M Simpson H
Full Access

Abstract

OBJECTIVES

Staphylococcus aureus is one of the most common pathogens in orthopaedic biomaterial-associated infections. The transition of planktonic S. aureus to its biofilm phenotype is critical in the pathogenesis of biomaterial-associated infections and the development of antimicrobial tolerance, which leads to ineffective eradication in clinical practice. This study sought to elucidate the effect of non-lethal dispersion on antimicrobial tolerance in S. aureus biofilms.

METHODS

Using a methicillin-sensitive S. aureus reference strain, the effect of non-lethal dispersion on gentamicin tolerance, cellular activity, and the intracellular metabolome of biofilm-associated bacteria were examined. Gentamicin tolerance was estimated using the dissolvable bead biofilm assay. Cellular activity was estimated using the triphenyltetrazolium chloride assay. Metabolome analysis was performed using tandem high-performance liquid chromatography and mass spectrometry.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 6 - 6
1 Mar 2021
Styczynska-Soczka K Amin A Simpson H Hall A
Full Access

Abstract

Objectives

The development of promising therapeutics for cartilage repair/regeneration have been hampered by the inadequacy of existing animal models and lack of suitable translational ex-vivo human tissue models. There is an urgent unmet need for these to assess repair/regenerative (orthobiologic) treatments directly in human tissue. We describe methodology allowing the successful long-term ex-vivo culture of non-degenerate whole human femoral heads that may be used as a model for testing new orthobiologic therapies.

Methods

Fifteen fresh, viable human femoral heads were obtained from 15 patients (with ethical permission/consent) undergoing hemiarthroplasty for hip fracture, and cultured aseptically (37°C) for up to 10wks. Culture conditions included static/stirred standard media (Dulbecco's modified Eagle's medium; DMEM) and supplementation with 10% human serum (HS). Chondrocyte viability, density, cell morphology, cell volume, glycosaminoglycan(GAG)/collagen content, surface roughness and cartilage thickness were quantified over time.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 55 - 55
1 Jul 2020
Jalal MMK Wallace R Simpson H
Full Access

Many pre-clinical models of atrophic non-union do not reflect the clinical scenario, some create a critical size defect, or involve cauterization of the tissue which is uncommonly seen in patients. Atrophic non-union is usually developed following high energy trauma leading to periosteal stripping. The most recent reliable model with these aspects involves creating a non-critical gap of 1mm with periosteal and endosteal stripping. However, this method uses an external fixator for fracture fixation, whereas intramedullary nailing is the standard fixation device for long bone fractures.

OBJECTIVES

To establish a clinically relevant model of atrophic non-union using intramedullary nail and (1) ex vivo and in vivo validation and characterization of this model, (2) establishing a standardized method for leg positioning for a reliable x-ray imaging.

Ex vivo evaluation: 40 rat's cadavers (adult male 5–6 months old), were divided into five groups (n=8 in each): the first group was fixed with 20G intramedullary nail, the second group with 18G nail, the third group with 4-hole plate, the fourth group with 6-hole plate, and the fifth group with an external fixator. Tibiae were harvested by leg disarticulation from the knee and ankle joints. Each group was then subdivided into two subgroups for mechanical testing: one for axial loading (n=4) and one for 4-point bending (n=4) using Zwick/Roell® machine. Statistical analysis was carried out by ANOVA with a fisher post-hoc comparison between groups. A p-value less than 0.05 was considered statistically significant.

To maintain the non-critical gap, a spacer was inserted in the gap, the design was refined to minimize the effect on the healing surface area. In vivo evaluation was done to validate and characterize the model. Here, a 1 mm gap was created with periosteal and endosteal stripping to induce non-union. The fracture was then fixed by a hypodermic needle.

A proper x-ray technique must show fibula in both views. Therefore, a leg holder was used to hold the knee and ankle joints in 90º flexion and the foot was placed in a perpendicular direction with the x-ray film. Lateral view was taken with the foot parallel to the x-ray film.

Ex vivo: axial load stiffness data revealed that intramedullary nails are significantly stronger and stiffer than other devices. Bending load to failure showed that 18G nails are significantly stronger than 20G, thus it is used for the in vivo experiments.

In vivo: final iteration revealed 3/3 non-union, and in controls with the periosteum and endosteum intact but with the 1mm non-critical gap, it progressed to 3/3 union.

X-ray positioning: A-P view in supine position, there was an unavoidable degree of external rotation in the lower limb, thus the lower part of the fibula appeared behind the tibia. To overcome this, a P-A view of the leg was performed with the body in prone rather, this arrangement allowed both upper and lower parts of the fibula to appear clearly in both views.

We report a novel model of atrophic non-union, the surgical procedure is relatively simple and the model is reproducible.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 58 - 58
1 Jul 2020
Hamilton D Simpson H Beard D Barker K MacFarlane G Stoddart A Murray G
Full Access

There is a lack of evidence as to the best way to deliver rehabilitation following TKA. Previous work has suggested that postoperative physiotherapy applied to all patients is not effective at improving one-year post-surgical outcomes. The aim of this study was to target physiotherapy to those at risk of poor outcome following TKA, and to determine if a therapist-led intervention offered superior results compared to a home-exercise based protocol in this ‘at risk’ group.

The Targeted Rehabilitation to Improve Outcomes (TRIO) study was a prospective randomised controlled trial run at 15-centres in the UK. Patients were identified as ‘potential poor outcome’ based on an Oxford Knee Score (OKS) classification at 6-weeks post-surgery and randomised to either therapist-led or home-exercise based protocols. Patients were reviewed by a physiotherapist and commenced 18-exercise sessions over 6-weeks. The therapist-led group undertook a progressive functional protocol (modified weekly in 1-1 contact sessions) in contrast to the static home-exercise based regime. Evaluation took place following rehabilitation intervention, then at 6-months and 1-year post-surgery. Primary outcome was comparative group OKS at 1-year. Secondary outcomes included, ‘worst’ and ‘average’ pain scores, OXS and EQ-5D, and satisfaction questionnaire. Health economic (cost-utility) analysis was undertaken from NHS perspective up to 1-year post-surgery. Incremental cost per Quality Adjusted Life Years (QALYs) were calculated from intervention costs, patient reported primary and secondary care usage, and EQ-5D data.

4264 patients were screened, 1296 were eligible, 334 patients were randomised, 8 were lost to follow-up, therapy compliance was >85%. Clinically meaningful improvement in OKS (between baseline and 1-year) was seen in both arms (p < 0 .001). Between group difference in 1-year OKS was 1.91 (95%CI, −0.17–3.99) points favouring the therapist-led arm (p=0.07). Incorporating all time point data, between group difference in OKS was 2.25 points (95%CI, 0.61–3.90, p=0.008). Small, non-significant reductions (< 5 %) in both worst and average pain scores were observed favouring the therapist-led group. Enhanced satisfaction with pain relief (OR 1.65, p < 0 .02), ability to perform daily functional tasks (OR 1.66, p < 0 .02), and perform heavy functional tasks (OR 1.6, p=0.04) was reported in the therapist-led group. There was a small non-significant difference of 0.02 points (95%CI −0.02–0.06) between groups in EQ-5D, resulting in a £12,125 cost per QALY of delivering the therapist led intervention with a 57% chance of being cost-effective at the standard UK policy threshold of £20,000 per QALY.

TRIO is the largest randomised trial of physiotherapy following TKA, and the first to target rehabilitation to patients at risk of poor outcomes. Both therapist-led and home-exercise based rehabilitation groups made clinically meaningful improvements in outcome by 1-year. We observed a modest difference in OKS in favour of therapist-led rehabilitation compared to the home-exercises which was not statistically significant. The relatively tight confidence intervals suggests that any difference which might exist is too small to be clinically relevant. Patient satisfaction with outcome was however higher in those that received greater physiotherapist contact. While cost per QALY estimates were below UK policy threshold, this result is uncertain and insufficient to make accept-decline recommendations.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 22 - 22
1 Jul 2020
Tsang J Gwynne P Gallagher M Simpson H
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, with cumulative treatment costs for all prosthetic joint infections estimated to be ∼ $1 billion per annum (UK and North America). Its ability to develop resistance or tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explored, but preliminary work has shown potential benefit, especially when combined with existing antibiotics. Low intensity pulsed ultrasound is already licensed for clinical use in fracture management and thus could be translated quickly into a clinical treatment

Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, biofilms were challenged with gentamicin +/− low-intensity ultrasound (1.5MHz, 30mW/cm2, pulse duration 200µs/1KHz) for 180 minutes and 20 minutes, respectively. The primary outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin. The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. Assessment of cellular metabolism was conducted using a liquid-chromatography-mass spectrometry, as well as a triphenyltetrazolium chloride assay coupled with spectrophotometry.

There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was reduced to 64mg/L. Metabolic activity of biofilm-associated S. aureus was increased by 25% following ultrasound therapy (p < 0 .0001), with identification of key biosynthetic pathways activated by non-lethal dispersal.

Low intensity pulsed ultrasound was associated with a four-fold reduction in the effective biofilm eradication concentration of gentamicin, bringing the MBEC of gentamicin to within clinically achievable concentrations. The mechanism of action was due to partial disruption of the extracellular matrix which led to an increase of nutrient availability and oxygen tension within the biofilm. This metabolic stimulus was responsible for the reversal of gentamicin tolerance in the biofilm-associated S. aureus.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 44 - 44
1 Jul 2020
Wallace R Xie S Simpson H
Full Access

Trabecular bone is a multiscale hierarchical composite material that is known to display time-dependant properties. However, most biomechanical models treat this material as time independent. Time-dependant properties, such as creep and relaxation, are thought to play an important role in many clinically relevant orthopaedic issues: implant loosening, vertebral collapse, and non-traumatic fractures. In this study compressive multiple-load-creep-unload-recovery (MLCUR) tests were applied to human trabecular bone specimens.

15 female femoral heads were harvested, with full ethical approval and patient consent, at the time of total hip replacement. Central cores were extracted and cut parallel under constant irrigation. Specimens were embedded in end caps using surgical cement, an epoxy tube was secured around the end caps and filled with phosphate buffered saline (PBS) to ensure the specimens remained hydrated throughout. Embedded samples were scanned by microCT (SkyScan 1172, Bruker) at a resolution of 17µm to determine microarchitecture. Bone volume fraction (BVF) was used to represent microarchitecture. Specimens had an effective length of 16.37mm (±1.90SD) with diameter of 8.08mm (±0.05SD), and BVF of 19.22% (±5.61SD).

The compressive MLCUR tests were conducted at 5 strain levels, 2000µε, 4000µε, 6000µε, 8000µε and 10000µε. At each strain level, the load required to maintain each strain was held for 200s (creep) then unloaded to 1N for 600s (recovery). The instantaneous, creep, unloading and recovered strains can be easily obtained from the strain-time curves. Stress-strain plots revealed the Young's modulus. Data was modelled using line of best fit with appropriate curve fitting. R2 values were used to indicate association. Mechanical testing demonstrated the expected time independent relationship between BVF and stiffness: higher stiffness was found for specimen with higher BVF and this was consistent for all strain levels.

Creep strain was found to depend on instantaneous strain and BVF. At low levels of instantaneous strain, there was a greater amount of creep strain in low BVF samples (R2 = 0.524). This relationship was no longer apparent at higher strain levels (R2 = 0.058). Residual strain also depended on the applied instantaneous strain and BVF: at low levels of strain, residual strain was similar with all BVF (R2 = 0.108) and at high levels of strain, residual strain was greater in low BVF samples (R2 = 0.319). The amount of instantaneous strain applied to each sample is constant, variations in stiffness result in different applied loads. In low BVF bone, the stiffness is also low, therefore the stress required to reach designed strain is also lower: yet, there is more creep and less recovery.

We have demonstrated that even at loads below recognised yield levels, time-dependence affects the mechanical response and residual strain is present. In cases of low BVF, deflection due to creep, and increased irrecoverable strain could have clinically relevant consequences, such as implant loosening and vertebral collapse. The role of time-dependant properties of bone is seldom considered. This data could be developed into a constitutive model allowing these time-dependant behaviours to be incorporated in finite element modelling, leading to better predictions of implant loosening, especially for lower quality bone.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 5 - 5
1 Mar 2020
Nicholson J Clelland A MacDonald D Clement N Simpson H Robinson C
Full Access

To evaluate if clinical recovery following midshaft clavicle fracture is associated with nonunion and determine if this has superior predictive value compared to estimation at time of injury.

A prospective study of all patients (≥16 years) who sustained a displaced midshaft clavicle fracture was performed. We assessed patient demographics, injury factors, functional scores and radiographic predictors with a standardized protocol at six-weeks. Conditional-stepwise regression was used to assess which factors independently predicted nonunion at six-months post-injury determined by CT. The nonunion predictor six-week model (NUP6) was compared against a previously validated model based on factors available at time of injury (NUP0-smoking, comminution and fracture displacement).

200 patients completed follow-up at six months. The nonunion rate was 14% (27/200). Of the functional scores, the QuickDASH had the highest accuracy on receiver-operator-characteristic (ROC) curve analysis with a 39.8 threshold, above which was associated with nonunion (Area Under Curve (AUC) 76.8%, p<0.001).

On regression modelling QuickDASH ≥40 (p=0.001), no callus on radiograph (p=0.004) and fracture movement on examination (p=0.001) were significant predictors of nonunion. If none were present the predicted nonunion risk was 3%, found in 40% of the cohort (n=80/200). Conversely if two or more were present, found in 23.5% of the cohort, the predicted nonunion risk was 60%.

The NUP6 model appeared to have superior accuracy when compared to the NUP0 model on ROC curve analysis (AUC 87.3% vs 64.8% respectively).

Delayed assessment at six-weeks following displaced clavicle fracture enables a more accurate prediction of fracture healing.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 44 - 44
1 Jan 2019
Jalal M Simpson H Peault B
Full Access

Cutting rodent's bone ends and irrigation of the medullary canal is the common method used for cells collection in allogenic transplantation, however it does not yield sufficient cells for autologous transplantation. The aim of this experiment was to establish and validate a method for bone marrow collection for autologous MSCs transplantation. Two collection methods were examined: 1) Transection of the bone ends and irrigation of the medullary canal, 2) Trephining of the bone with a hypodermic needle without aspiration. Then cell harvesting was compared in the idealised laboratory situation and under simulated surgery.

First, two lower limbs were harvested from the same rat cadaver for comparison, bone marrow in one limb was collected by cutting the femoral head and the distal tibia and irrigation of the canal through drilled holes at the distal end of the femur and proximal end of the tibia. Other limb, hypodermic needle was used as a trephining tool into the medullary canal multiple times without applying negative pressure and rinsed from inside and outside. Second, bone marrow was harvested from another rat's cadaver in the surgery room to simulate the conditions needed for autologous transplantation.

The number of cells from irrigation method was 1.28*106 cells, whereas that from trephining method reached 17*106. The number cells from the bone marrow harvested in the surgery room was found 29.6*106. We report a novel technique for harvesting cells for autologous cell therapy from only one limb. A significantly larger number of cells from bone marrow could be collected using the needle trephining method. There is no negative effect on the viability of cells after bone marrow harvesting in the surgery room.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 8 - 8
1 Jan 2019
Jalal M Simpson H Wallace R Peault B
Full Access

In atrophic non-union models, a minimally invasive technique is used to deliver stem cells into the fracture site via percutaneous injection. This technique is significantly affected by a backflow leakage and the net number of cells might be reduced. The Z-track method is a technique used in clinical practice for intramuscular injections to prevent backflow leakage.

We evaluated the potential of the Z-track injection technique for preventing cell loss in non-union models by determining the behaviour of observable marker fluids. Firstly, toluene blue stain was used as an injection material to allow visual detection of its distribution. Rat's cadaver legs were used and tibias were kept unbroken to ensure intact skin and overlying soft tissue. Technique includes pulling the skin over the shin of tibia towards the ankle and injection of the dye around the mid-shaft. The needle was then partially pulled back, the skin was returned to its normal position and a complete extraction of the needle was followed. Secondly, a mixture of contrast material and toluene blue was used to allow direct visual and radiological detection of the injected material into the fracture site. Ante-grade nailing of tibia via tibial tuberosity was carried out followed by a 3 point closed fracture. Injection was performed into the fracture gap similarly to the steps above. X-rays were taken to visualise the location and distribution of the injected material.

Observation revealed no blue stain could be detected over the skin, X -rays revealed that the radiopaque dye remained around the tibia with no escape of the material into the superficial layers or onto the skin surface. Therefore, the number of cells delivered and maintained at a target site could be increased by the Z-track method and therefore, the therapeutic benefit of stem cell injections could be optimised with this simple technique.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 17 - 17
1 Jan 2019
Jalal M Simpson H Wallace R
Full Access

Appropriate in vivo models can be used to understand atrophic non-union pathophysiology. In these models, X-ray assessment is essential and a reliable good quality images are vital in order to detect any hidden callus formation or deficiency. However, the radiographic results are often variable and highly dependent on rotation and positioning from the detector/film. Therefore, standardised A-P and lateral x-ray views are essential for providing a full radiological picture and for reliably assessing the degree of fracture union.

We established and evaluated a method for standardised imaging of the lower limb and for reliably obtaining two perpendicular views (e.g. true A-P and true lateral views). The normal position of fibula in murine models is posterolateral to the tibia, therefore, a proper technique must show fibula in both views. In order to obtain the correct position, the knee joint and ankle joints were flexed to 90 degrees and the foot was placed in a perpendicular direction with the x-ray film. To achieve this, a leg holder was made and used to hold the foot and the knee while the body was in the supine position. Lateral views were obtained by putting the foot parallel to the x-ray film. Adult Wister rat cadavers were used and serial x-rays were taken.

A-P view in supine position showed the upper part of the fibula clearly, however, there was an unavoidable degree of external rotation in the whole lower limb, and the lower part of the fibula appeared behind the tibia. Therefore, a true A-P view whilst the body was in the supine position was difficult. To overcome this, a P-A view of the leg was performed with the body prone position, this allowed both upper and lower parts of the fibula to appear clearly in both views. This method provides two true perpendicular views (P-A and lateral) and helped to optimise radiological assessment.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 43 - 43
1 Jan 2019
Tsang J Gwynne P Gallagher M Simpson H
Full Access

Staphylococcus aureus is responsible for 60–70% infections of surgical implants and prostheses in Orthopaedic surgery, costing the NHS £120–200 million per annum. Its ability to develop tolerance to a diverse range of antimicrobial compounds, threatens to halt routine elective implant surgery. One strategy to overcome this problem is to look beyond traditional antimicrobial drug therapies and investigate other treatment modalities. Biophysical modalities, such as ultrasound, are poorly explores, but preliminary work has shown potential benefit, especially when combined with existing antibiotics.

Using a methicillin-sensitive S. aureus reference strain and the dissolvable bead assay, bacterial biofilms were challenged by gentamicin +/− low-intensity ultrasound (1.5MHz, 30W/cm2, pulse duration 200µs/1KHz) for 20 minutes. The outcome measures were colony-forming units/mL (CFU/mL) and the minimum biofilm eradication concentration (MBEC) of gentamicin.

The mean number of S. aureus within control biofilms was 1.04 × 109 CFU/mL. There was no clinically or statistically significant (p=0.531) reduction in viable S. aureus following ultrasound therapy alone. The MBEC of gentamicin for this S. aureus strain was 256 mg/L. The MBEC of gentamicin with the addition of ultrasound was 64mg/L.

Low intensity pulsed ultrasound was associated with a four-fold reduction in the effective biofilm eradication concentration of gentamicin; bringing the MBEC of gentamicin to within clinically achievable concentrations


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 34 - 34
1 Jan 2019
Sehgal A Burnett R Howie C Simpson H Hamilton D
Full Access

Instability accounts for approximately 20% of revision total knee arthroplasty (TKA) operations, however, diagnostic tests remain relatively subjective. The aim of this examination was to evaluate the feasibility of using pressure mat analyses during functional tasks to identify abnormal biomechanics associated with TKA instability.

Five patients (M = 4; age = 69.80±7.05 years; weight = 79.73±20.12 kg) with suspected TKA instability were examined compared to 10 healthy controls (M = 4; age = 44.6±7.52 years; weight = 70.80±14.65). Peak pressure and time parameters were measured during normal gait and two-minute bilateral stance. Side-to-side pressure distribution was calculated over 10-second intervals during the second minute. Mann-Whitney tests compared loading parameters between groups and side-to-side differences in TKA patients (significance level = p<0.05).

Pressure distribution was expressed relative to bodyweight. Notable differences were seen during bilateral stance. Uneven side loading was greater – favouring the non-operated limb – in TKA patients during bilateral stance compared to controls. This was significantly different at 30s (p=0.0336) and 60s (p=0.0336). Gait analyses showed subtle pressure distribution differences in unstable TKA patients. Stance time was indifferent. TKA patients tended to exhibit longer heel contact time (0.76s vs. 0.64s and reduced weight acceptance (50.75% vs. 56.75%) on the operated limb compared to the non-operated limb. Side-to-side differences in peak toe-off forces were significantly more pronounced in TKA patients versus controls (9.25% +/− 1.5% vs. 1.67% +/−5.79%; p=0.0039).

Conclusion: This feasibility work demonstrates subtle differences in limb loading mechanics during simple clinical tests in unstable TKA patients that might be invisible to the naked eye. In the long-term, pressure analyses may be a useful diagnostic tool in identifying patients that would benefit from revision surgery for TKA instability.


There is a growing trend towards using pre-clinical models of atrophic non-union. This study investigated different fixation devices, by comparing the mechanical stability at the fracture site of tibia bone fixed by either intramedullary nail, compression plate or external fixator. 40 tibias from adult male Wistar rats' cadavers were osteotomised at the mid-shaft and a gap of 1 mm was created and maintained at the fracture site to simulate criteria of atrophic non-union model. These were divided into five groups (n=8 in each): the first group was fixed with 20G intramedullary nail, the second group with 18G nail, the third group with 4-hole plate, the fourth group with 6-hole plate, and the fifth group with external fixator. Tibia was harvested by leg disarticulation from the knee and ankle joints, the soft tissues were carefully removed from the leg, and tibias were kept hydrated throughout the experiment. Each group was then subdivided into two subgroups for mechanical testing: one for axial loading (n=4) and one for 4-point bending (n=4).

Statistical analysis was carried out by ANOVA with a fisher post-hoc comparison between groups. A p-value less than 0.05 was considered statistically significant. Axial load to failure data and stiffness data revealed that intramedullary nails are significantly stronger and stiffer than other devices, however there was no statistically significant difference axially between the nail thicknesses. In bending, load to failure revealed that 18G nails are significantly stronger than 20G. We concluded that 18G nail is superior to the other fixation devices, therefore it has been used for in-vivo experiments to create a novel model of atrophic non-union with stable fixation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 45 - 45
1 Nov 2018
Barlow C Dominguez E Dixon G Crouch-Smith H Wallace R Simpson H Al-Hourani K
Full Access

Femoral shaft fractures are potentially devastating injuries. Despite this, clinical studies of the biomechanics of this injury are lacking. We aimed to clinically evaluate bone behaviour under high and low energy trauma in paediatric, adult and older patients. Single-centre retrospective study identifying all diaphyseal femoral fractures between Feb 2015-Feb 2017. Peri-prosthetic and pathological fractures were excluded. Patients were subdivided into groups 1 (paediatric, <16yo), 2 (adult, 17–55yo) and 3 (older, >55yo) to reflect immature, peak bone age and osteoporotic bone respectively. Chi-Squared analysis assessed significance of bone age to degree of comminution and fracture pattern. A p-value <0.05 was significant. A total 4130 radiographs were analysed with 206 femoral shaft fractures identified. Forty-three patients were excluded with 163 remaining. Group 1, 2 and 3 included 38, 37 and 88 patients respectively. Mean age 50.8 (SD 32.8) with male-to-female ratio of 1:1.2. Groups 1 and 3 included majority simple fractures (35/38 and 62/88 respectively). Group 2 included more comminuted injuries (33/37). Bone age to degree of comminution proved significant (p<0.05) with a bimodal distribution of simple fractures noted in groups 1 and 3. Energy to fracture was significant in group 2, where a high energy injury was associated with comminution (p<0.05). This study is the first to demonstrate an association between fracture comminution and age. Simple femoral shaft fractures showed a bimodal age distribution in paediatric and older patients regardless of mechanism energy. High energy mechanism trauma was directly related to fracture comminution at peak bone age.