Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 22 - 22
1 May 2016
Angibaud L Petrera P Petrera J Silver X Hamad C
Full Access

Introduction

One main perceived drawback for the adoption of computer assisted orthopedic surgery (CAOS) during total knee arthroplasty (TKA) relates to the increased surgical time compared to the use of standard mechanical instrumentation [1]. This study compared the time efficiency between a next generation CAOS system (ExactechGPS®, Blue-Ortho, Grenoble, FR) and conventional mechanical instrumentation, and assessed the impact of surgeon experience level on the efficiency.

Materials and methods

Surgical time was retrospectively reviewed on 63 primary TKAs performed by a board-certified orthopedic surgeon (PP) using a cemented postero-stabilized knee system (Optetrak Logic PS, Exactech, Gainesville, FL), grouped as 1) Group I (control): 21 TKAs using conventional mechanical instruments; 2) Group II: 21 TKAs performed using the CAOS system with an early experience level (first 21 cases); and 3) Group III: 21 TKAs using the CAOS system with an advanced experience level (beyond 30 cases). Surgical time was compared across the three groups (with significance defined as p<0.05).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 15 - 15
1 Feb 2016
Petrera P Petrera J Silver X Angibaud L
Full Access

One main perceived drawback for the adoption of computer assisted orthopaedic surgery (CAOS) during total knee arthroplasty (TKA) relates to the increased surgical time compared to the use of standard mechanical instrumentation. This study compared the time efficiency between a next generation CAOS system (ExactechGPS®, Blue-Ortho, Grenoble, FR) and conventional mechanical instrumentation, and assessed the impact of surgeon experience level on the efficiency.

Surgical time was retrospectively reviewed on 63 primary TKAs performed by a board-certified orthopaedic surgeon (PP) using the Optetrak Logic® PS knee system (Exactech, Gainesville, FL), grouped as 1) Group I (control): 21 TKAs using conventional mechanical instruments; 2) Group II: 21 KAs performed using the CAOS system with an early experience level (first 21 cases); and 3) Group III: 21 TKAs using the CAOS system with an advanced experience level (beyond 30 cases). Patient condition (age, BMI, gender, etc.), surgical technique, and post-operative guidelines were similar across the three groups. No cases were lost and no patient had any intra-operative complications. Surgical time was compared across the three groups (with significance defined as p<0.05).

Compared to the TKAs using conventional mechanical instrumentation, the average surgical time for the navigated TKAs performed with an early experience was 7 minutes longer. However, with an advanced experience level, the average surgical time was 2 minutes less than the time required using conventional mechanical instrument. Further, navigated TKAs with an advanced experience level exhibited the least variability among the three groups. None of the time differences were significant (p>0.20).

No significant difference in TKA surgical time was found between the evaluated CAOS system (both within or pass the learning curve) and the conventional instrumentation. Nevertheless, once the learning curve was reached, the system decreased the time variability compared to conventional mechanical instrumentation. The comparable efficiency reported in this study to the conventional mechanical instrumentation may be attributed to the unique features of the ExactechGPS system, such as indication for use inside the sterile field, blood occlusion-resistant tracker design, customisable operative technique tailored to the surgeon's preference, and compact and reduced number of instruments.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 19 - 19
1 Jan 2016
Angibaud L Liebelt RA Gao B Silver X
Full Access

Introduction

From pre-operative planning to final implant cementation, total knee arthroplasty (TKA) preparation is a succession of many individual steps, each presenting potential sources of error that can result in devices being implanted outside the targeted range of alignment. This study assessed alignment discrepancy occurring during different TKA steps using an image-free computer-assisted orthopaedic surgery (CAOS) guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) in normal and abnormal mechanical axis.

Materials and methods

We used a commercially available artificial leg (MITA trainer leg M-00058, Medical Models, Bristol, UK) able to receive (neutral / varus / valgus) knee inserts simulating the proximal tibia and distal femur. A pre-surgical profile was established to define resection parameters for the proximal tibial and distal femoral cuts (Figure 1A). Data from the guidance system were collected at three separate steps: (1) cutting block adjusted but not pinned to the bone (Figure 1B), (2) cutting block adjusted and pinned to the bone (Figure 1C), and (3) after the cuts were checked (Figure 1D). These data were then compared to the resection target parameters to track potential dispersions occurring during the process.

Due to the amount of data (i.e., four studied resection parameters per bone, three operative steps, and three knee model types), the authors introduced an “error index”, which was a unitless indication of overall error magnitude obtained by averaging the absolute values of all linear and angular measurement errors. Due to knee model dimensions (∼55 mm), the authors equally considered linear and angular measurement values (i.e., 1 mm equivalent to 1°).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 20 - 20
1 Jan 2016
Angibaud L Liebelt RA Gao B Silver X
Full Access

Introduction

An emerging consensus in the surgical specialties is that skill acquisition should be more emphasized during surgical training.1 This study was an attempt to evaluate the effects of repetitive practices using an image-free computer-assisted orthopaedic surgery (CAOS) guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) on both technical and cognitive skills.

Materials and methods

A senior knee replacement surgeon with limited previous experience with the CAOS system performed a series of consecutive simulated knee surgeries using a commercially available artificial leg (MITA trainer leg M-00058, Medical Models, Bristol, UK).

In order to assess the effects repetitive practice has on technical skills, we evaluated two indexes:

Error index: A unitless indication of overall error magnitude obtained by averaging the absolute values of all linear and angular measurement differences between targeted and checked cuts.

Time index: An indication of the time required to acquire landmarks, adjust the custom blocks, and make cuts.

In order to assess the effect repetitive practice has on cognitive skills, we evaluated the number of times the surgeon elected to deviate from pre-surgical planning or re-acquire landmarks.

We evaluated these parameters for three chronological and consecutive groups of simulated surgeries: Group A (knee models #1 to #10), Group B (knee models #11 to #20), and Group C (knee models #21 to #28).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2016
Angibaud L Liebelt RA Gao B Gulbransen S Silver X
Full Access

Introduction

Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning.1 The use of computer-assisted orthopaedic surgery (CAOS) can improve overall TKA accuracy.2 This study assessed the accuracy of an image-free CAOS guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) in both a synthetic leg with a normal mechanical axis and legs with abnormal mechanical axis.

Materials and methods

A high-resolution 3D scanner (Comet L3D, Steinbichler, Plymouth, MI) was used to scan varus-deformed (n=12), neutral (n=12), and valgus-deformed (n=4) knee inserts (Mita M-00566, M-00598, M-00567; respectively, Medical Models, Bristol, UK) and collect pre-identified anatomical landmarks prior to using the models to simulate knee surgery. The image-free CAOS guidance system was then used to acquire the same landmarks. After adjusting the position and orientation of the cutting block to match the targets, bone resections were performed, and the knee models were re-scanned. The 3D scans made before and after the cuts were overlaid and the resection parameters calculated using the pre-identified anatomical landmark data and advanced software (UG NX, Siemens PLM, Plano, TX). Data sets obtained from the 3D scanner (see Figure 1A) were compared with data sets from the guidance system (see Figure 1B). Given the accuracy of the 3D scanner (<50μm), its measurements were used as the baseline for assessing CAOS system error.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 229 - 229
1 Dec 2013
Angibaud L Silver X Gulbransen S Stulberg B
Full Access

Introduction

From pre-operative planning to final implant cementation, total knee arthroplasty (TKA) can be defined by a succession of individual steps, each presenting potential errors that can result in devices being implanted outside the desired range of alignment.

Our study used an image-free computer-assisted orthopedic surgery (CAOS) guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) to evaluate alignment discrepancies occurring during different steps of a typical TKA procedure.

Materials and methods:

A surgical profile was established to define resection parameters and steps for proximal tibial and distal femoral cuts (see Figure 1A) to be made on seven synthetic knee models (MITA, Medical Models, Bristol, UK). First, the guidance system was used to acquire pre-identified landmarks. Next, a cutting block was adjusted to match the resection targets and then fixed to the bone using locking pins. Bone cuts were performed and then checked. Data was collected from the guidance system at three steps: (1) cutting block adjusted but not pinned to bone (see Figure 1B), (2) cutting block adjusted and pinned to bone (see Figure 1C), and (3) after checking cuts (see Figure 1D). These data were then compared to the resection target parameters to assess potential discrepancies.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 7 - 7
1 Dec 2013
Angibaud L Silver X Gulbransen S Stulberg B
Full Access

Introduction

Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning.1 The use of computer-assisted orthopedic surgery (CAOS) can improve overall TKA accuracy.2 This study assessed the accuracy of an image-free CAOS guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) used in TKA.

Materials and methods:

A high-resolution 3D scanner (Comet L3D, Steinbichler, Plymouth, MI) was used to scan seven knee models (MITA, Medical Models, Bristol, UK) and collect pre-identified anatomical landmarks (see Figure 1) prior to using the models to simulate knee surgery.

The image-free CAOS guidance system was then used to acquire the same landmarks. After adjusting the position and orientation of the cutting block to match the targets, bone resections were performed, and the knee models were re-scanned. The 3D scans made before and after the cuts were overlaid (see Figure 2) and the resection parameters calculated using the pre-identified anatomical landmark data and advanced software (XOV & XOR, RapidForm, Lakewood, CO and UG NX, Siemens PLM, Plano, TX). Data sets obtained from the 3D scanner were compared with data sets from the guidance system. Given the accuracy of the 3D scanner, its measurements were used as the baseline for assessing CAOS system error.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 107 - 107
1 Aug 2013
Angibaud L Silver X Gulbransen S Stulberg B
Full Access

Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning. The use of computer-assisted orthopedic surgery (CAOS) can improve overall TKA accuracy. This study assessed the accuracy of an image-free CAOS guidance system (Exactech GPS, Blue-Ortho, Grenoble, FR) used in TKA.

A high-precision 3D scanner (Comet L3D, Steinbichler, Plymouth, MI) was used to scan seven knee models (MITA, Medical Models, Bristol, UK) and collect pre-identified anatomical landmarks prior to using the models to simulate knee surgery. The Exactech GPS was then used to acquire the same landmarks. After adjusting the Exactech GPS cutting block to match the targets, bone resections were performed, and the knee models were re-scanned. The 3D scans made before and after the cuts were overlaid and the resection parameters calculated using the pre-identified anatomical landmark data and advanced software (XOV & XOR, RapidForm, Lakewood, CO and UG NX, Siemens PLM, Plano, TX). Data sets obtained from the 3D scanner were compared with data sets from the guidance system. Given the accuracy of the 3D scanner, its measurements were used as the baseline for assessing CAOS system error.

The CAOS system bone resection measurement errors had an overall mean of less than 0.35 mm. The mean errors for joint angle measurement was less than 0.6°. Even considering the ranges, errors were no more than 1 mm for all bone resection measurements and no more than 1° for all joint angle measurements. The low variability is also supported by small SD values.

To our knowledge, this is the first study to use a high-resolution 3D scanner to assess the accuracy of surgical cuts made with image-free CAOS system assistance. Determining precise landmarks using CAOS for TKA has been shown to be of critical importance. For this reason, the anatomical landmarks used by the scanner and guidance system were carefully identified and prepared to ensure consistency.

The study demonstrated that the evaluated image-free CAOS system was able to achieve a high level of in-vitro accuracy (small mean errors) as well as a high level of precision (small error variability) when making femoral and tibial bone resections during TKA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVI | Pages 23 - 23
1 Apr 2012
Mandalia V William C Brown K Schranz P Silver D Redfern A Powell R
Full Access

The aim of this prospective study was to determine the prevalence of bone marrow oedema (BME) in asymptomatic knees of athletes and to investigate the factors associated with appearance of BME in this group.

A total of 25 asymptomatic athletes who competed at an international, national or county level during their most recent sport season were recruited in this study and had MRI scan of both knees (n=50). MRI scans were reported independently by two experienced musculoskeletal radiologists. Statistical analysis included Cohen's kappa test to identify inter-observer agreement for MRI diagnosis of bone marrow oedema and multiple logistic regression model to identify the factors associated with BME on MRI scan.

There was very good agreement between radiologists for diagnosis of BME (Kappa = 0.896). Seven participants (28%) were found to have BME. Six of the participants had BME in unilateral knees and one participant had BME in bilateral knees. The commonest location of BME was medial femoral condyle (62.5%) The amount of time spent in preseason training (34-38 weeks) was significantly associated with appearance of BME (P=0.048)

BME seems to be common in asymptomatic athletes and one should realize that this finding might not be related to the clinical complaints of the patients. The results of the present study show that there is a training effect associated with BME. Knowing what is a ‘normal’ or ‘abnormal’ scan is important for a competitive athlete, as erroneously diagnosing BME as the underlying cause of athletes' symptoms could lead to decreased playing time or inappropriate therapy.