header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 10 - 10
1 Nov 2021
Tikhilov R Shubnyakov I
Full Access

Detection of clinical situations are the most difficult for primary THA and factors which determine the complexity.

Results of 2368 primary THA performed by one surgeon in 1923 patients with various hip pathologies from 2004 to 2016 were analyzed. The time of the surgery, the bloodloss, the features of the surgical technique, the implants used, and the incidence of complications and revisions were assessed and X-ray analysis was performed.

Difficult cases of primary hip arthroplasty include severe dysplasia (types B2, C1, and C2 according to the Hartofilakidis classification), post-traumatic segmental acetabular defects and pelvic discontinuity, protrusio acetabuli, iatrogenic bone ankylosis and consequences of proximal femur fractures with significant shortening of the limb.

X-ray signs of difficulty included an interruption of the Shenton line of 2 cm or more (except for acute fractures of proximal femur), the femoral neck-shaft angle less than 100°, and the horizontal distance from Kohler line to center of rotation less than 20% of the diameter of the femoral head. An additional burdening factor is the previous surgical interventions on the hip joint.

The ten-year survival rate for standard cases was 94.9%, and for complex cases − 92.3%. The odds ratio development of complications in complex cases compared to standard cases is OR = 8.402 (95% CI from 4.614 to 15.300). In standard cases mean HHS increased from 42.9 points before surgery to 95.3 after surgery. In complex cases mean HHS before surgery was 38.9 and after surgery improved to 81.6 points, p <0.001.

The complexity of the operation cannot be determined on the basis of only the etiological factor, it is necessary to take into account the severity of anatomical changes.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 14 - 14
1 Aug 2018
Tikhilov R Shubnyakov I Denisov A Pliev D
Full Access

Evaluation of the anatomical features, details of surgical technique and results of the THA in patients with CDH (type C1 and C2 by G. Hartofilakidis).

From 2001 to 2016 years one surgical team performed 683 THA in patients with CDH. We retrospectively studied 561 total hip arthroplasties in 349 patients, follow-up rate was 82.1%, from 12 to 188 months (mean 69.4). The results were evaluated by clinical examination, X-rays analysis, Harris Hip Score.

Unilateral high hip dislocation was observed in 175 patients (31.2%), in these cases often have underdeveloped half of the pelvis on the side of the dislocation. Type C1 was observed in 326 cases and type C2 – in 235 cases. Type C1 in comparison with C2 has less leg length discrepancy, developed shape of proximal femur, presence of supraacetabular osteophyte. The mean displacement of femoral head was 47.6 mm (from 29 to 55) for C1 and 63.4 mm (from 41 to 78) for C2. Average offset in C1 was 50.1 mm (37–63) and in C2 − 44.3 mm (34–52).

Shortening osteotomy by T. Paavilainen performed in 165 cases (50.6%) with C1 dysplasia and in 235 cases (100%) with C2. The features of surgical technique were small size of the cups with obligatory additional screw fixation of the cup and small offset of the stems. The cup was positioned into the true acetabulum in 99.1% cases of C2 type, for C1 – only 69.0%). The cups size 44 mm were used in 97.3% cases for type C2 and in 78.6% cases for type C1. For shortening osteotomy in 76.3% cases Wagner Cone stems were used.

Early complications included 9 dislocations (1.6%), 8 femoral nerve neuropathies (1.4%) and 3 infections (0.5%). There is no sciatic nerve palsy. Late complications included dislocation in two hips (1.1%), nonunion of the greater trochanter (8.4%), aseptic loosening of the femoral component − 2 (0.8 %), aseptic loosening of the cup − 11 (1.6%). Average Harris Hip score improved from 39.5 to 83.6 with unsignificant diffence between types C1 and C2 (from 37.3 to 81.4 and from 40.4 to 85.1 consequently). Revision rate was 2.1% for type C1 and 5.5% for type C2.

Hip replacement surgery in patients with high hip dislocation is very challenging. Type C2 dysplasia has only one surgical option with good long-term results – placement of the cup into the true acetabulum and shortening osteotomy. Its advantages include leg length alignment and decreased risk of sciatic nerve injury. Type C1 dysplasia presents more heterogenic group of patients and allows to use several surgical options – different placement of the cup and surgical approach without shortening osteotomy. Functional results in patients with type C1 are a little bit worse in comparison with type C2, but C1 had less risk of complications. The main problem of shortening osteotomy by Paavilainen is delayed union and non-union of great trochanter.