header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 73 - 73
1 Nov 2018
Masieri FF Schofield JR Velloso CP Ballisat J Setti S Cadossi R Abdel-Maguid M
Full Access

Pulsed Electromagnetic Fields (PEMFs) promote joint tissue anabolic activities, particularly in cartilage and bone. Here we investigated the effect of selected PEMFs (75Hz, 1.5mT, 1.3msec) in a differentiating model of murine myoblasts (C2C12) in vitro. C2C12 were seeded at 5×103 cells/cm2 in 4 well plates and left to adhere for 24h. Subsequently, cells were either maintained in growth medium (GM) or induced towards myogenic differentiation in low-serum conditions, with and without PEMF exposure, for 4 days. Morphological analysis, myotube formation and fusion index (FI) were assessed with fluorescence microscopy techniques. Metabolic activity was determined by MTT; moreover, a multiplex cytokine array (RayBiotech) allowed cell supernatant molecule quantification. Cells exposed to PEMFs in GM acquired a distinctive elongated morphology, with increased bi-nuclear figures (3.2-fold FI increase over PEMF-unexposed cells) and displayed a significantly higher metabolic activity (+31%, p<0.05 over PEMF-unexposed cells). PEMF exposure increased metabolic activity also under myogenic differentiation (+15% over PEMF-unexposed differentiating cells, p<0.05), with the formation of long, thick polynuclear myotubes, suggesting a role of PEMFs in enhancing myogenesis (7.7-fold FI increase over PEMF-unexposed cells). 4-day culture supernatants revealed the presence of several myokines (KC/CXCL1, LIX, MCP-1, TIMP-1). Preliminary analysis showed a 1.16-fold increase (n=2) of LIX and, notably, a 1.91-fold increase (n=2) of TNF-RI, in cell supernatants of PEMF-exposed over PEMF-unexposed cells. Collectively, these results suggest that PEMF may successfully be applied in models of muscle cell trauma to optimise muscle fibre repair, by fine-tuning the release of myokines, promoting myoblast proliferation and myotube formation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 35 - 35
1 Nov 2018
Vincenzi F Pasquini S Setti S Cadossi M Borea P Cadossi R Varani K
Full Access

Several studies explored the biological effects of low frequency low energy pulsed electromagnetic fields (PEMFs, Igea Biophysics Laboratory, Carpi, Italy) on human body reporting different functional changes. In the orthopedic field, PEMFs have been shown to be effective in enhancing endogenous bone and osteochondral repair, incrementing bone mineral density, accelerating the process of osteogenic differentiation and limiting cartilage damage. Much research activity has focused on the mechanisms of interaction between PEMFs and membrane receptors such as adenosine receptors (ARs). In particular, PEMF exposure mediates a significant upregulation of A2A and A3ARs expressed in various cells or tissues involving a reduction of most of the pro-inflammatory cytokines. In tissue engineering for cartilage repair a double role for PEMFs could be hypothesized: in vitro by stimulating cell proliferation, colonization of the scaffold and production of tissue matrix; in vivo after surgical implantation of the construct by favoring the anabolic activities of the implanted cells and surrounding tissues and protecting the construct from the catabolic effects of inflammation. Of particular interest is the observation that PEMFs, through the increase of ARs, enhance the working efficiency of the endogenous modulator adenosine, producing a more physiological effect than the use of exogenous drugs. This observation suggests the hypothesis that PEMFs could be considered a non-invasive treatment with a low impact on daily life. In conclusion, PEMFs represent an important approach in the pharmacological field providing excellent therapeutic results in various inflammatory diseases and in particular in the functional recovery of the damaged joint tissues.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 4 - 4
1 Nov 2018
Orfei CP Lovati A Lugano G Viganò M Bottagisio M D'Arrigo D Setti S de Girolamo L
Full Access

Tendon-related pathologies such as tendinopathy represent a relevant clinical and socioeconomic issue. The most innovative and conservative therapeutic approaches are meant to stimulate the intrinsic healing capability of the tissue. In this study, the use of pulsed electromagnetic fields (PEMFs) was investigated in a rat model of Achilles tendinopathy as a potential therapy. Achilles tendinopathy was chemically induced in eighty-six Sprague Dawley rats by injecting collagenase Type I within the tendon fibers. Fifty-six of them were stimulated with PEMFs (8 hours/day, 1.5 ± 0.2 mT; 75 Hz), divided in different experimental groups basing on the starting-time of PEMFs exposure (after 0, 7, 15 after Collagenase injection) and its duration (7, 15 or 30 days). Thirty animals were left unstimulated (CTRL group). According to the different time points, explanted tendons were evaluated through histological and immunohistochemical analyses in term of matrix deposition, fiber re-organization, neovascularization and inflammatory reaction. The most effective PEMF stimulation was demonstrated in the 15 days of treatment. However, when PEMF were applied immediately after the collagenase injection, no significant therapeutic results were found. On the contrary, when PEMF were applied after 7 and 15 days from the collagenase injection, they promoted the deposition of extracellular matrix and tendon fiber re-organization, reducing both the inflammatory reaction and vascularization, with significant differences compared to the CTRL group (p<0.05). Therefore, these results suggest an effective activity of PEMFs stimulation that provides a satisfying restoration of the damaged tissue, although the most performing protocol of application still needs to be identified.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 17 - 17
1 Jan 2017
Viganò M Orfei CP Lovati A Stanco D Bottagisio M Di Giancamillo A Setti S de Girolamo L
Full Access

Tendinopathies represent the 45% of the musculoskeletal lesions and they are a big burden in clinics. Indeed, despite the relevant social impact, both the pathogenesis and the development of the tendinopathy are still under-investigated, thus limiting the therapeutic advancement in this field. Indeed, current treatment for tendinopathy are mainly symptomatic, and they present a high rate of pathology re-occurrence. In this contest, the development of an efficient in vivo model of acute tendinopathy, focused on the choice of the most appropriate species and strategy to induce the disease, would allow a better understanding of the pathology progression throughout its phases.

Then, the purpose of this study was to evaluate the dose-dependent and time-related tissue-level changes occurring in a collagenase-induced tendinopathy in rat Achilles tendons, in order to establish a standardized model for future pre-clinical studies.

40 Sprague Dawley rats were randomly divided into two groups, treated by injection of collagenase type I within the Achilles tendon at 1 mg/mL (low dose, LD) or 3 mg/mL (high dose, HD). Tendon explants were histologically evaluated at 3, 7, 15, 30 and 45 days by H&E staining.

Our results showed that both the collagenase doses induced a disorganization of collagen fibers and increased the number of rounded resident cells. In particular, the high dose treatment determined a greater fatty degeneration and neovascularization with respect to the lower dose. These changes are time-dependent, thus resembling the tendinopathy development in humans. Indeed, the acute phase occurred from day 3 to day 15, while from day 15 to 45 it progressed towards the proliferative phase, displaying a degenerative appearance associated with a precocious remodeling process.

The model represents a good balance between feasibility, in terms of reproducibility and costs, and similarity with the human disease. Moreover, the present model contributes to improve the knowledge about tendinopathy development, and then it could be useful to design further pre-clinical studies, in particular in order to test innovative treatments for tendinopathy.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 23 - 23
1 Jul 2014
Viganò M Stanco D Setti S Galliera E Sansone V de Girolamo L
Full Access

Summary

In an in vitro tendon cell model, the tendon-specific gene expression up-regulation induced by PEMF negatively correlates with field intensity; moreover repeated lower-intensity PEMF treatments (1.5 mT) provokes a higher release of anti-inflammatory cytokines respect to the single treatment.

Introduction

Tendon disorders represent a diagnostic and therapeutic challenge for physicians. Traditional treatments are characterised by a long recovery time and a high occurrence of injury relapses. Despite the growing clinical interest in pulsed electromagnetic fields (PEMFs) few studies on their effect on tendons and ligaments have been conducted. Tendon resident cells (TCs) are a mixed population, made up mostly by tenocytes and tendon stem/progenitor cells, which are responsible of the tissue homeostasis. Since studies on the effect of PEMFs on this cell population are conflicting, we evaluated the possible relation between PEMFs dosage and TCs’ response. In particular, we compared the in vitro effect of low and high PEMFs on TCs (PEMF-1.5 mT; PEMF-3 mT); moreover we assessed the results of repeated treatments (R-PEMF-1.5mT).