header advert
Results 1 - 4 of 4
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 11 | Pages 1522 - 1527
1 Nov 2008
Davis ET Olsen M Zdero R Waddell JP Schemitsch EH

A total of 20 pairs of fresh-frozen cadaver femurs were assigned to four alignment groups consisting of relative varus (10° and 20°) and relative valgus (10° and 20°), 75 composite femurs of two neck geometries were also used. In both the cadaver and the composite femurs, placing the component in 20° of valgus resulted in a significant increase in load to failure. Placing the component in 10° of valgus had no appreciable effect on increasing the load to failure except in the composite femurs with varus native femoral necks. Specimens in 10° of varus were significantly weaker than the neutrally-aligned specimens.

The results suggest that retention of the intact proximal femoral strength occurs at an implant angulation of ≥ 142°. However, the benefit of extreme valgus alignment may be outweighed in clinical practice by the risk of superior femoral neck notching, which was avoided in this study.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 7 | Pages 1054 - 1061
1 Sep 2002
Bhandari M Schemitsch EH

High-pressure lavage produces greater visible damage to bone at a macroscopic and microscopic level when compared with low-pressure lavage and can result in delay in the healing of fractures. Osteoblasts and adipocytes are derived from mesenchymal stem cells. Conditions which lead to bone loss often involve a switch from the osteoblast to adipocyte lineage. We have therefore examined the effect of high- and low-pressure irrigation on the differentiation of adipocytes.

Calvaria-derived bone cells were exposed to either low-pressure or high-pressure irrigation with normal saline. After 14 days the cells were fixed and the osteoblasts and adipocytes quantified using Oil Red O to stain cytoplasmic lipid droplets (triglycerides) in the cells. Osteoblasts were quantified using a commercially available alkaline-phosphatase staining assay.

A standard quantitative reverse transcription-polymerase chain reaction (RT-PCR) was performed. Messenger RNA levels for osteocalcin, a marker of osteoblasts, and PPARγ2, a marker of adipocytes, were measured. High-pressure lavage resulted in an increase in adipogenesis of 50% when compared with low-pressure lavage.

Our findings suggest that high-pressure lavage may promote differentiation of mesenchymal stem cells towards the adipoctye lineage. This may have clinical significance in the development of delayed and nonunion after treatment of fractures of long bones.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 360 - 364
1 Mar 1998
McKee MD Yoo D Schemitsch EH

Previous studies of the Ilizarov procedure have concentrated on musculoskeletal assessments rather than the opinions of patients. In a prospective trial of 25 consecutive patients, we evaluated the effect of Ilizarov reconstruction of post-traumatic deformity on general health status using the SF36 and Nottingham Health Profile (NHP).

The patients had very low preoperative scores, which remained low during treatment and correction, but increased postoperatively. The mean overall SF36 score improved from 36 ± 3 to 58 ± 7 (p = 0.031) and the NHP score from 39 ± 11 to 67 ± 10 (p = 0.002). The improvements in scores were not limited to the physical components and were equal or better than the improvements reported for other orthopaedic procedures, including total joint arthroplasty.

Ilizarov-type reconstruction of deformity of the lower limb not only restores bony configuration, but also produces a large improvement in the general health status of patients.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 1 | Pages 156 - 161
1 Jan 1998
ElMaraghy AW Humeniuk B Anderson GI Schemitsch EH Richards RR

We examined the roles of methylmethacrylate (MMA) monomer and cementing technique in the formation, and haemodynamic outcome, of pulmonary fat emboli. The preparation of the femoral canal and the cementing technique were studied in four groups of adult dogs as follows: control (no preparation); lavage; cement pressurisation; and cement pressurisation after lavage. We measured the intramedullary pressure, pulmonary artery pressure (PAP), pulmonary capillary wedge pressure and bilateral femoral vein levels of triglyceride, cholesterol and MMA monomer at rest and after reaming, lavage, and cementing.

Femoral vein triglyceride and cholesterol levels did not vary significantly from resting levels despite significant elevations in intramedullary pressure with reaming, lavage and cementing (p = 0.001). PAP was seen to rise significantly with reaming (p = 0.0038), lavage (p = 0.0031), cementing (p = 0.0024) and cementing after lavage (p = 0.0028) while the pulmonary capillary wedge pressure remained unchanged.

MMA monomer was detected in femoral vein samples when cement pressurisation was used. Intramedullary lavage before cementing had no significant effect on the MMA level. Haemodynamic evidence of pulmonary embolism was noted with reaming and intramedullary canal preparation, irrespective of the presence of MMA monomer. We found no relationship between MMA monomer level and intramedullary pressure, PAP or pulmonary capillary wedge pressure.

Our findings suggest that the presence of MMA monomer in femoral venous blood has no effect on the formation of fat emboli or their pulmonary haemodynamic outcome during cemented hip arthroplasty.