header advert
Results 1 - 3 of 3
Results per page:
Bone & Joint Open
Vol. 2, Issue 11 | Pages 900 - 908
3 Nov 2021
Saunders P Smith N Syed F Selvaraj T Waite J Young S

Aims

Day-case arthroplasty is gaining popularity in Europe. We report outcomes from the first 12 months following implementation of a day-case pathway for unicompartmental knee arthroplasty (UKA) and total hip arthroplasty (THA) in an NHS hospital.

Methods

A total of 47 total hip arthroplasty (THA) and 24 unicompartmental knee arthroplasty (UKA) patients were selected for the day-case arthroplasty pathway, based on preoperative fitness and agreement to participate. Data were likewise collected for a matched control group (n = 58) who followed the standard pathway three months prior to the implementation of the day-case pathway. We report same-day discharge (SDD) success, reasons for delayed discharge, and patient-reported outcomes. Overall length of stay (LOS) for all lower limb arthroplasty was recorded to determine the wider impact of implementing a day-case pathway.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 36 - 36
1 May 2019
Syed F Magra M Saunders P Ugwuoke A Young S
Full Access

Introduction

Primary fixation in uncemented Total Hip Replacement (THR) is achieved by implanting an appropriately sized stem. Last year, in our pilot study, we classified undersizing & reported the incidence of subsidence & radiolucent lines (RLL) in undersized uncemented stems. Now we report on a larger cohort of patients, reporting undersizing and its association with radiolucent lines and subsidence. Secondarily we report on the effect of using a collar, patients' BMI, and in a smaller group the five-year failure rate.

Methods

A retrospective review of electronic records of 1337 cases who underwent THR using the Corail stem was carried out. 1204 (Collared 1042, Uncollared 162) had a minimum follow up of 1 year, 693 of those had a follow up of at least 5 years. Radiological review was carried out by 2 independent investigators.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 38 - 38
1 May 2018
Magra M McConnell J Syed F Saunders P Young S
Full Access

Introduction

Undersizing of an uncemented femoral stem is a post-operative description of a radiograph with unclear clinical importance. It may not always translate into a suboptimal clinical outcome.

Aim

To describe a novel classification system of undersizing in a fully hydroxyapatite coated femoral implant, assess if it could be reliably reported between observers, and describe a simple way to assess the degree of undersizing on an AP radiograph.