header advert
Results 1 - 2 of 2
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 259 - 265
1 Mar 2004
Saldanha KAN Saleh M Bell MJ Fernandes JA

We performed limb lengthening and correction of deformity of nine long bones of the lower limb in six children (mean age, 14.7 years) with osteogenesis imperfecta (OI). All had femoral lengthening and three also had ipsilateral tibial lengthening. Angular deformities were corrected simultaneously. Five limb segments were treated using a monolateral external fixator and four with the Ilizarov frame. In three children, lengthening was done over previously inserted femoral intramedullary rods.

The mean lengthening achieved was 6.26 cm (mean healing index, 33.25 days/cm). Significant complications included one deep infection, one fracture of the femur and one anterior angulation deformity of the tibia. The abnormal bone of OI tolerated the external fixators throughout the period of lengthening without any episodes of migration of wires or pins through the soft bone. The regenerate bone formed within the time which is normally expected in limb-lengthening procedures performed for other conditions.

We conclude that despite the abnormal bone characteristics, distraction osteogenesis to correct limb-length discrepancy and angular deformity can be performed safely in children with OI.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 2 | Pages 254 - 260
1 Mar 2003
Donnan LT Saleh M Rigby AS

We have reviewed, retrospectively, all children with a lower limb deformity who underwent an acute correction and lengthening with a monolateral fixator between 1987 and 1996. The patients were all under the age of 19 years and had a minimum follow-up of eight months after removal of the fixator. A total of 41 children had 57 corrections and lengthening. Their mean age was 11.3 years (3.2 to 18.7) and there were 23 girls and 18 boys.

The mean maximum correction in any one plane was 23° (7 to 45). In 41 bony segments (either femur or tibia) a uniplanar correction was made while various combinations were carried out in 16. The site of the osteotomy was predominantly diaphyseal, at a mean of 47% (17% to 73%) of the total bone length and the mean length gained was 6.4 cm (1.0 to 17.0).

Univariate analysis identified a moderately strong relationship between the bone healing index (BHI), length gained, maximum correction and grade-II to grade-III complications. For logistic regression analysis the patients were binary coded into two groups; those with a good outcome (BHI ≤ 45 days/cm) and those with a poor outcome (BHI > 45 days/cm). Various factors which may influence the outcome were then analysed by calculating odds ratios with 95% confidence intervals.

This analysis suggested a dose response between increasing angular correction and poor BHI which only reached statistical significance for corrections of larger magnitude. Longer lengthenings were associated with a better BHI while age and the actual bone lengthened had little effect.

Those patients with a maximum angulatory correction of less than 30° in any one plane had an acceptable consolidation time with few major complications. The technique is suitable for femoral deformity and shortening, but should be used with care in the tibia since the risk of a compartment syndrome or neurapraxia is much greater.