header advert
Results 1 - 2 of 2
Results per page:

Aims

The aim of this study was to compare the efficacy of a corticosteroid injection for the treatment of carpal tunnel syndrome (CTS) in patients with and without Raynaud’s phenomenon.

Patients and Methods

In a prospective study, 139 patients with CTS were treated with a corticosteroid injection (10 mg triamcinolone acetonide); 34 had Raynaud’s phenomenon and 105 did not (control group). Grip strength, perception of touch with a Semmes-Weinstein monofilament and the Boston Carpal Tunnel Questionnaires (BCTQ) were assessed at baseline and at six, 12 and 24 weeks after the injection. The Cold Intolerance Severity Score (CISS) questionnaire was also assessed at baseline and 24 weeks after the injection.


Bone & Joint Research
Vol. 5, Issue 2 | Pages 37 - 45
1 Feb 2016
Roh YH Kim W Park KU Oh JH

Objectives

This study was conducted to evaluate the cytokine-release kinetics of platelet-rich plasma (PRP) according to different activation protocols.

Methods

Two manual preparation procedures (single-spin (SS) at 900 g for five minutes; double-spin (DS) at 900 g for five minutes and then 1500 g for 15 minutes) were performed for each of 14 healthy subjects. Both preparations were tested for platelet activation by one of three activation protocols: no activation, activation with calcium (Ca) only, or calcium with a low dose (50 IU per 1 ml PRP) of thrombin. Each preparation was divided into four aliquots and incubated for one hour, 24 hours, 72 hours, and seven days. The cytokine-release kinetics were evaluated by assessing PDGF, TGF, VEGF, FGF, IL-1, and MMP-9 concentrations with bead-based sandwich immunoassay.