header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 472 - 472
1 Aug 2008
Charity R Day N Vasukutty N Ramesh M Kumar P
Full Access

Digital x-ray systems are now widely used in hospitals in the UK. Most systems have facilities to take measurements from the images that, we are lead to believe, can be used in accurate pre-operative planning. The aim of this study was to assess whether or not pre-operative planning can reliably predict the size of the implant required when using a hemiarthroplasty to treat an intracapsular hip fracture.

A magnification factor was calculated for pre-operative pelvic x-rays using typical beam to plate distance and plate to hip distance. The pre-operative digital radiographs of 188 consecutive patients who underwent a hip hemiarthroplasty were examined. The femoral head diameters of both the fractured and non-fractured sides were measured. The size of the implanted prosthesis was also recorded from the patients’ operation notes. The x-ray measurements were multiplied by the magnification factor and compared with the known size of the prosthesis. The calculated magnification factor was 128%. Attempts at estimating implant size from measurements of the fractured and non-fractured sides underestimated the size of the prosthesis by 3.0mm (CI 6.5 to −0.5) and 3.1mm (CI 6.8 to −0.6) respectively.

Many hospitals do not stock the full range of hemiarthroplasty implants on the shelf. Sizes at the extremes of the range may need to be specially ordered. It is important that the correct size prosthesis be inserted; an oversized prosthesis can increase the risk of dislocation and an undersized prosthesis will result in point loading and acetabular erosion. Our study shows that pre-operative planning consistently underestimates the size of the implant. However, the accuracy of these estimations is not sufficiently reliable, being +/− 3.5mm, to be able to accurately predict the size of the prosthesis required. Reasons for the under estimation are likely to be due to the fact that the measurement taken from the images does not account for the articular cartilage covering the femoral head. One of the factors leading to inaccuracy in the estimation is variation in patient anatomy and habitus, which affects hip to plate distance and thus the magnification factor. Also, the distance of the beam to plate will vary according to the radiographer’s positioning of the x-ray source.

In order to accurately pre-operatively plan the size of the prosthesis one would need to standardise the beam to hip distance. radio-opaque markers would need to be positioned at the level of the hip in order to accurately calculate the magnification factor. Without these modifications, we do not feel that hip prosthesis size can be accurately predicted from pre-operative images.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 465 - 465
1 Aug 2008
Kumar P Prabakaran M Ramesh M Clay M
Full Access

Scaphoid fractures are commonly seen fractures following distal radius fractures, yet its diagnosis can be difficult. The present study is to explore the diagnostic approach to suspected scaphoid fractures in a district general hospital in the UK.

This is a retrospective study. 286 Suspected scaphoid injuries were seen in our Fracture clinics. 184/286 were known to have normal x-ray findings initially and repeat x-ray in 10 days time. They were all treated as a simple case of a sprained wrist. 40 Patients out of the remaining 102 patients were noted to have scaphoid fractures on follow up x-rays and accordingly treated with cast. The remaining 62 patients were considered for further imaging. 28/102 went for bone scan, which confirmed scaphoid fracture in 4/28 cases. It also picked up other degenerative pathology in 4/28 cases. The rest of the scans were normal. 22/102 Were sent for CT scan which identified the fracture in 20 cases. CT scans provided details about the configuration of fracture, level of healing etc. MRI was performed in 12/102 cases, which confirmed fracture in 2/12 cases and bone bruising in 2/12 cases.

There is no consensus regarding the investigation of choice when a follow up scaphoid x-ray is inconclusive in diagnosing a possible scaphoid fracture. In this study we note that a bone scan does not offer much information. On the other hand MRI and CT investigations were useful. We recommend the use of an MRI investigation for a fresh injury, and a CT scan for fresh and old injuries.


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 229 - 233
1 Mar 1999
Ramesh M Morrissey B Healy JB Roy-Choudhury S Macey AC

Acute swelling of the hand is a common problem after trauma or surgery and is associated with both pain and loss of function. We describe a prospective study of 47 patients in which we assessed the effects of a pneumatic compression device (A-V impulse hand pump) on the swollen hand. The pump reduced swelling by increasing the velocity of venous return as demonstrated by Duplex scanning of the median cubital vein.

Continuous use of the pump for 48 hours gave a reduction of 78.6% in swelling of the injured hand compared with the opposite, uninjured side. Even when used intermittently, with the pump on for 12 hours out of 24, a statistically significant effect was seen.

There was a subjective reduction in pain and an objective improvement in function of the hand. Use of the pump resulted in a nearly normal hand by the time of discharge from hospital after, on average, 48 hours.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 903 - 906
1 Nov 1996
Ramesh M O’Byrne JM McCarthy N Jarvis A Mahalingham K Cashman WF

We studied prospectively 81 consecutive patients undergoing hip surgery using the Hardinge (1982) approach. The abductor muscles of the hip in these patients were assessed electrophysiologically and clinically by the modified Trendelenburg test. Power was measured using a force plate. We performed assessment at two weeks, and at three and nine months after operation.

At two weeks we found that 19 patients (23%) showed evidence of damage to the superior gluteal nerve. By three months, five of these had recovered. The nine patients with complete denervation at three months showed no signs of recovery when reassessed at nine months. Persistent damage to the nerve was associated with a positive Trendelenburg test.