header advert
Results 1 - 20 of 40
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 18 - 18
1 May 2017
Buldu M Raman R
Full Access

Background

We herein report a case of isolated hip pain in a four year old boy. The unique aspect of this case study is the unusual history, presentation, ultrasonography, MRI and blood culture results, which lead to the diagnosis and treatment of adductor pyomyositis with a rare organism (Streptococcus Mitis) in a temperate country. The objectives of this case study is to discuss the key learning outcomes with respect to assessment and management of this case.

Methods

The patient presented with a one day history of malaise, fever, left groin pain and inability to weight bear on the left leg. There was no history of any trauma, predisposing infections or recent travel. A working diagnosis of transient synovitis / septic arthritis of the hip was made on clinical examination.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 10 - 10
1 Dec 2015
Buldu M Raman R
Full Access

We herein report a case of isolated hip pain in a four year old boy. The importance of this project is the unusual history, presentation, ultrasound, MRI and blood culture results and treatment, which lead to the diagnosis of adductor pyomyositis with a rare organism (Streptococcus Mitis) in a temperate country.

The patient presented with a one day history of malaise, fever, left groin pain and inability to weight bear on the left leg. There was no history of any predisposing infections or recent travel. A working diagnosis of transient synovitis / septic arthritis of the hip was made on clinical examination.

Plain radiograph and ultrasound of the hip was normal with no effusion. Two consecutive blood cultures suggested Streptococcus Mitis bacteriaemia and MRI scan confirmed pyomyositis of the left hip adductors that was too small to drain. Streptococcus Mitis is a normal commensal organism of the oral cavity however it can lead to opportunistic infections particularly endocarditis. Echocardiogram revealed no cardiac complications, in particular no endocarditic vegetation.

Patient was treated with intravenous benzylpenicillin for a week followed by oral phenoxymethylpenicillin for a week. As it was a soft tissue infection, a short course of antibiotics was sufficient and he made a complete recovery. Adductor pyomyositis must be considered as a differential diagnosis in a child with unusual presentation of hip pain. When an ultrasound is normal, MRI scan is warranted to confirm diagnosis. Septic screen should include blood cultures. The commonest organisms are the Staphylococcus family. However if Streptococcus Mitis is isolated, cardiac sources of infection resulting in septic emboli must be investigated. Repeated MRI scans are required particularly if the patient does not respond to medical management


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 629 - 635
1 May 2014
Inacio MCS Kritz-Silverstein D Raman R Macera CA Nichols JF Shaffer RA Fithian DC

This study evaluated whether obese patients who lost weight before their total joint replacement and kept it off post-operatively were at lower risk of surgical site infection (SSI) and re-admission compared with those who remained the same weight.

We reviewed 444 patients who underwent a total hip replacement and 937 with a total knee replacement who lost weight pre-operatively and sustained their weight loss after surgery. After adjustments, patients who lost weight before a total hip replacement and kept it off post-operatively had a 3.77 (95% confidence interval (CI) 1.59 to 8.95) greater likelihood of deep SSIs and those who lost weight before a total knee replacement had a 1.63 (95% CI 1.16 to 2.28) greater likelihood of re-admission compared with the reference group.

These findings raise questions about the safety of weight management before total replacement of the hip and knee joints.

Cite this article: Bone Joint J 2014;96-B:629–35.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_3 | Pages 6 - 6
1 Jan 2013
Sarmah S Fenton C Raman R Gopal S Roy N Sharma H
Full Access

Purpose of study

The aim of this study is to evaluate the role of low intensity pulsed ultrasound, Exogen in the treatment of delayed and non unions. Methodology: We conducted a retrospective study of 292 patients who has had Exogen treatment for delayed and non union from 2005 to 2009. Patient's age, sex, associated co morbidities, smoking history, medications, type of fractures (open/closed), infection and site of fractures were sought for. 271 patients' data (228 delayed and 43 non unions) were available during the study with mean age of 53.5 yrs.

Exogen therapy was initiated at 3–4 months for delayed unions and 6–12 months for non unions in 61 tibia (15 open); 31 femur (2 open); 20 scaphoid; 38 5th metatarsal; 31 ankle (2 open); 17 ulna (1 open); 15 radius (3 open); 29 humerus (2 open); 16 clavicles; 6 olecranon; 4 pilon (2 open) and 2 metacarpal fractures.

Discussion

Union was achieved in 196 patients (72.3%) of which 11 (5.6%) were smokers. In 73 (26.9 %) patients union was not achieved of which 53 (72 %) were smokers. The mean healing timing after application of Exogen was 16 weeks for delayed union and 26.6 weeks for non union. 5 (31.2%) pt out of 16 in the DM group went into non union.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_2 | Pages 5 - 5
1 Jan 2013
Singh J Marwah S Platt A Barlow G Raman R Sharma H
Full Access

Aim

Chronic osteomyelitis still remains challenging and expensive to treat in spite of advances in antibiotics and operative techniques. We present our experience with free muscle flap after radical debridement of chronic osteomyelitis, performed as a single stage procedure.

Methods

We retrospectively identified eight patients (5 Females) with mean age of 63 yrs (Range 40–71 yrs) Case notes were reviewed for co morbidities, Pre and post treatment inflammatory markers (plasma viscosity and CRP) and clinical staging. Mean follow up was 3 yrs (Range 1–6 yrs)

All the patients were jointly operated by orthopaedic and plastic surgeons and underwent thorough debridement and muscle flap (Seven free flaps and one rotational flap) in the same sitting. All the patients were reviewed regularly by plastic and orthopaedic surgeons. Seven patients had free Gracilis flap and one had Triceps flap. Clinical assessment of reinfection was made on presence of erythema and wound discharge. Primary outcome measure was resolution of infection.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 111 - 111
1 Sep 2012
Raman R Johnson G Shaw C Graham V Cleaver N
Full Access

To report the clinical, functional and radiological outcome of consecutive primary hip arthroplasties using large diameter (36mm and above) ceramic bearing couples. We believe this to be one of the first independent series.

We prospectively reviewed 519 consecutive primary THA using fully HAC coated acetabular shell and fully HAC coated stem (JRI Ltd) in 502 patients, with minimum follow-up of 32 months. A Biolox-Delta ceramic liner with an 18 deg taper and Biolox-Delta ceramic head (36mm and 40mm) were used in all cases, by 3 surgeons. None were lost to follow-up. Clinical outcome was measured using Harris, Charnley Oxford, EuroQol EQ-5D scores. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Return to sports and hobbies were recorded.

Mean age was 64.9 yrs (11–82yrs). There were no dislocations. 50–62mm acetabular shells were used. 36 mm head was used in 92% of cases. No acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (1), peri-prosthetic fractures (1). The mean Harris and Oxford scores were 95 (88–97) and 14.1 (12–33) respectively. Harris and Oxford scores were 95 (88–97) and 14.1 (12–33) respectively. The Charnley score was 5.7 (5–6) for pain, 5.8 (4–6) for movement and 5.9 (4–6) for mobility. There was a significant improvement in the range of movement of the hip. There was no migration of acetabular component. Acetabular radiolucencies were present around one shell. No acetabular liner wear was demonstrated in CT Scans. Mean inclination was 7.4deg(37–65). Mean EQ-5D description scores and health thermometer scores were 0.84 (0.71–0.92) and 88 (66–96). With an end point of definite or probable loosening, the probability of survival was 100%. Overall survival with removal or repeat revision of either component for any reason as the end point was 99.1%.

The results of this study show an excellent clinical and functional outcome and support the use of a fully coated prosthesis with ceramic bearing couples. We envisage monitoring and prospectively reporting the long-term outcome of this series of patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 458 - 458
1 Sep 2012
Raman R Shaw C Johnson G Sharma H Day N Dutta A
Full Access

Introduction

Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20

Methods

Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID_s for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 130 - 130
1 Sep 2012
Raman R Johnson G Shaw C Graham N Cleaver V
Full Access

To discuss the rationale, selection criteria, indications, and results of using large diameter ceramic heads in revision hip arthroplasty.

We routinely use Biolox family of ceramic heads and acetabular liners in patients undergoing revision total hip replacements. We present our experience in using ceramic articular bearings over the last 20 years and the switch to larger diameter ceramic heads. We also present our rationale for using a large diameter ceramic head instead of a large metal head.

We reviewed a total of 689 revision arthroplasties over this time period and we report the outcome of large bearing couples with case examples in primary and revision scenarios. Furthermore we compared a subset of patients (110) with large diameter ceramic heads – Biolox Delta 36mm to patients who had metal on metal (large head 42 mm and above) bearing couples. The performance of the ceramic bearing couples will be discussed along with the functional outcome of these patients. We found no difference in the functional, clinical sports activities (UCLA and Tegner scores) between patients who had large metal bearing couples and large ceramic couples. Complication rate was less with the ceramic bearing revision arthroplasties, as was patient satisfaction.

Ceramic bearing couples have stood the test of time and have demonstrated an excellent long term wear properties. The recent introduction of the large diameter couples proves to be an excellent alternative if not the first choice in young, complex primary and revision case scenarios.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 91 - 91
1 Sep 2012
Raman R Singh J Johnson G Sharma H Day N Shaw C
Full Access

Introduction

Viscosupplementation is used widely to provide symptomatic relief to patients with knee OA. This study aimed to compare the efficacy and safety of the standard (3×2ml) and single (1×6ml) dosing regimens of hylan G-F 20.

Methods

Prospective, randomized, blinded (reviewers), comparative independent study. Inclusion criteria was OA knee pain e 60mm on a 100mm VAS; no prior intra articular (IA) injection. Patients were randomised to recieve 1 × 6mL or 3 × 2mL hylan G-F 20. Follow-up at 1, 6, 12, 26 and 52 weeks. Analgesics prohibited for 24 hours prior to follow-up assessments and NSAID's for 26 wks. All adverse events (AE) were recorded. Primary outcome measure: Target knee pain (VAS) at 26 weeks. Secondary outcome measures included WOMAC, Oxford knee score, SF12


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 60 - 60
1 May 2012
Raman R Dickson D Angus P Ridge J Johnson G Graham A
Full Access

We aim to report the clinical and radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong HAC coated femoral and acetabular components.

We reviewed 586 consecutive cementless primary THA in 542 patients with a minimum 12-18 year follow-up, performed at one institution between 1986 and 1994. Twenty-eight (32 THA) were lost to follow-up. Clinical outcome was measured using Harris, Charnley and Oxford scores. Quality of life using EuroQol

EQ-5D. Radiographs were systematically analysed.

The mean age was 75.2 years. Dislocation occurred in 12 patients (three recurrent). Re operations were performed in 11 patients (1.9%). Four acetabular and one stem revisions were performed for aseptic loosening. Other re-operations were for infection (two), periprosthetic fractures (two), cup malposition (one), revision of worn liner (two). The mean Harris and Oxford scores were 89 (79–96) and 18.4 (12–32) respectively. The Charnley score was 5.7 for pain, 5.3 for movement and 5.4 for mobility. Acetabular radiolucencies were present in 54 hips (9.7%).

The mean linear polythene wear was 0.06 mm/year. Stable stem by bony ingrowth was identified in all hips excluding one femoral revision case. Mean stem subsidence was 2.2mm (0.30–3.4mm). Radiolucencies were present around 37 (6.6%) stems. EQ- 5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, survival at 12 years was 96.1% for acetabular and 98.3% for femoral components. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 97.2%.

The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long-term period.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 224 - 224
1 May 2012
Raman R Dickson D Sharma H Angus P Shaw C Johnson G Graham A
Full Access

We report the clinical and radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong Hydroxyapatite ceramic (HAC) coated acetabular components.

We reviewed 412 consecutive cementless primary THA using fully coated acetabular shell in 392 patients—with a minimum 12 to 18 year follow-up—performed at two institutions between 1986 and 1994. Twenty (22 THA) were lost prior to 12-year follow-up, leaving 372 patients (390 THA) available for study. Fully HAC coated stems were used in all patients. The clinical outcome was measured using Harris, Charnley and Oxford hip scores and the quality of life using EuroQol EQ-5D. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Polythene wear was digitally measured. The radiographic stability of the acetabular component was determined by Enghs criteria.

The mean age was 74.4 years. The mean Harris and Oxford scores were 87 (78– 97) and 19.1 (12–33) respectively. The Charnley score was 5.6 (5-6) for pain, 5.2 (4–6) for movement and 5.3 (4–6) for mobility. Migration of acetabular component was seen in four hips. Acetabular radiolucencies were present in 54 hips (9.7%). The mean linear polythene wear was 0.06mm/year. Mean inclination was 48.4° (38–65).

Radiolucencies were present around 37 (6.6%) stems. Dislocation occurred in 10 patients (three recurrent). Re-operations were performed in nine patients (1.9%). Four acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (three), periprosthetic fractures (one), cup malposition (one) and revision of worn liner (three). Mean EQ-5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, the probability of survival at 12 years was 97.1% for acetabular component. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 96.2%.

The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long-term period.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 80 - 80
1 Mar 2012
Raman R Eswaramoorthy V Dickson D Madhu T Angus P
Full Access

Introduction

We aim to report the clinical and radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong HAC coated femoral and acetabular components.

Methods

We reviewed 586 consecutive cementless primary THA in 542 patients, with a minimum 12-year follow-up to 18 years, performed at one institution between 1986 and 1994. Twenty eight (32 THA) were lost to follow-up. Clinical outcome was measured using Harris, Charnley and Oxford scores. Quality of life using EuroQol EQ-5D. Radiographs were systematically analysed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 11 - 11
1 Feb 2012
Raman R Dutta A Day N Shaw C Johnson G
Full Access

Aim

To compare the clinical effectiveness, functional outcome and patient satisfaction following intra articular injection with Synvisc¯ and Hyalgan¯ in patients with osteoarthritis (OA) of the knee.

Methods

348 consecutive patients were randomised into two groups to receive either Hylan G-F 20 -Synvisc (n= 181) or Sodium Hyaluronate -Hyalgan (n=167). All patients were prospectively reviewed by independent assessors blinded for the treatment. Knee pain on a VAS were recorded. The functional outcome was assessed using Tegner, UCLA, Oxford knee score and EuroQol-5D scores. VAS was used to quantify patient satisfaction. Mean follow-up was 12 months.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 48 - 48
1 Feb 2012
Madhu T Raman R Giannoudis P
Full Access

To analyse and compare long-term functional outcome of combined spino-pelvic injuries to an isolated pelvis and spinal fractures, the outcome of matched 30 patients with combined pelvic and spinal fractures was compared with 32 patients with isolated pelvic fractures and 30 patients with isolated spinal fractures. Functional outcome was measured using the self-report questionnaire EuroQol EQ-5D, a generic outcome tool. The functional outcome was compared with the average UK population scores.

The mean age, median ISS and demographic profile were similar in all 3 groups. Neurological injuries were seen in 10 patients in the combined injury group, 5 patients in the pelvic injury group and 3 patients in the spinal fracture group. 1 patient had sexual dysfunction in the combined injury group. The EuroQol EQ-5D descriptive scores for the combined group were 0.67±0.11 (0.71±0.12 for spine fracture, 0.61±0.18 for pelvic fracture) and Valuation scores for the combined injury were 69.6±11.4 (65.1±19.4 for spine fracture, 61.5±21.9 for pelvic fracture), which are p=0.004 and p=0.003 for the combined injury compared to the average UK population. Duration of hospital stay was a mean of 13 days in spine injury group compared to 49 days in the combined injury group. 70% of patients with spinal injuries returned to the same level of employment in a mean duration of 5.3 months with only 10% retired due to injury; compared to 56.6% returned to work in the combined injury group after a mean duration of 12.8 months with 23.3% retired due to injury.

Long-term functional outcome is significantly better with isolated spinal injuries compared to pelvic injury or combined injury. There is no significant long-term difference between the combined spino-pelvic group and the isolated pelvic injury group. We feel that the spinal injuries in a patient with coexisting pelvic fracture do not contribute towards the overall functional outcome in those patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 93 - 93
1 Feb 2012
Giannoudis P Raman R Harwood P Allami M Dimitriou R Macdonald D Kind P
Full Access

We aimed to quantify the health related quality of life in a series of patients suffering a variety of different tibial injuries. Patients with previous tibial injury, randomly selected from our trauma database, who successfully completed their entire course of treatment at our institution, were recalled for final assessment. Mean time to final follow-up was 37.4 months. Statistical analysis was performed using SPSS computer software.

Overall, 130 patients were evaluated. There was no significant difference in the self-care dimension between the groups. Psychological problems were common in patients with IIIb and IIIc fractures, as well as amputees, with the highest incidence in those with IIIc fractures. Patients who had undergone amputation and those with IIIb open fractures reported problems with mobility significantly more frequently than those who had IIIc type injuries. However, this could be partially attributed to the significant difference in mean age between groups, with patients sustaining IIIc injuries being younger (31.9 vs 46.9). Patients with IIIb and IIIc type fractures reported significantly more problems with pain compared with those who had undergone amputation. Interestingly, patients who had undergone fasciotomy reported pain as frequently as amputees. Regarding the VAS, only patients with closed fractures reported significantly different scores from the mean of all the other groups.

These data represent the health related quality of life of patients having suffered the full spectrum of tibial injury and should be considered when determining the treatment options for these patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 222 - 222
1 May 2011
Raman R Johnson G Sharma H Gopal S Shaw C
Full Access

Aim: To discuss the rationale, selection criteria, indications, and results of using large diameter ceramic heads in primary and revision hip arthroplasty.

Patients and Methods: We routinely use Biolox family of ceramic heads and acetabular liners in patients undergoing total hip replacements. We present our experience in using ceramic articular bearings over the last 20 years and the switch to larger diameter ceramic heads. We also present our rationale for using a large diameter ceramic head instead of a large metal head.

Results: We reviewed a total of 1189 arthroplasties over this time period and we report the outcome of large bearing couples with case examples in primary and revision scenarios. Furthermore we compared a subset of patients (110) with large diameter ceramic heads – Biolox Delta 36mm to patients who had metal on metal (large head 42 mm and above) bearing couples. The performance of the ceramic bearing couples will be discussed along with the functional outcome of these patients. We found no difference in the functional, clinical sports activities (UCLA and Tegner scores) between patients who had large metal bearing couples and large ceramic couples. Complication rate was less with the ceramic bearing arthroplasties, as was patient satisfaction

Conclusion: Ceramic bearing couples have stood the test of time and have demonstrated an excellent long term wear properties. The recent introduction of the large diameter couples proves to be an excellent alternative if not the first choice in young, complex primary and revision case scenarios


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 220 - 220
1 May 2011
Raman R Johnson G Sharma H Gopal S Shaw C Singh J
Full Access

Aim: To report the clinical, functional and radiological outcome of consecutive primary hip arthroplasties using large diameter (36mm and above) ceramic bearing couples. We believe this to be one of the first reported series in the UK.

Methods: We prospectively reviewed 319 consecutive primary THA using fully HAC coated acetabular shell and fully HAC coated stem (JRI Ltd) in 302 patients, with minimum follow-up of 12 months. A Biolox-Delta ceramic liner with an 18 deg taper and Biolox-Delta ceramic head (36mm and 40mm) were used in all cases, which were performed in one institution by 3 surgeons. None were lost to follow-up. Clinical outcome was measured using Harris, Charnley Oxford, EuroQol EQ-5D scores. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Return to sports and hobbies were recorded.

Results: Mean age was 64.9 yrs (11–82yrs). There were no dislocations. 50–62mm acetabular shells were used. 36 mm head was used in 96% of cases. No acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (1), peri-prosthetic fractures (1). The mean Harris and Oxford scores were 95 (88–97) and 14.1 (12–33) respectively. The Charnley score was 5.7 (5–6) for pain, 5.8 (4–6) for movement and 5.9 (4–6) for mobility. There was a significant improvement in the range of movement of the hip. There was no migration of acetabular component. Acetabular radiolucencies were present around one shell. No acetabular liner wear was demonstrated in CT Scans. Mean inclination was 47.4deg(37–65). Mean EQ- 5D description scores and health thermometer scores were 0.84 (0.71–0.92) and 88 (66–96). With an end point of definite or probable loosening, the probability of survival was 100%. Overall survival with removal or repeat revision of either component for any reason as the end point was 99.1%.

Conclusion: The results of this study show an excellent clinical and functional outcome and support the use of a fully coated prosthesis with ceramic bearing couples. We envisage to monitor and prospectively report the long-term outcome of this series of patients.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 16 - 16
1 Jan 2011
Raman R Eswaramoorthy V Angus P Sharma H Madhu T Shaw C Johnson G
Full Access

We aim to report the clinical, radiological outcome of consecutive primary hip arthroplasties using the JRI-Furlong Hydroxyapatite ceramic coated acetabular components. We reviewed 412 consecutive primary THA using fully coated acetabular shell in 392 patients, with minimum 12-year follow-up to 18 years, performed at two institutions. Twenty (22 THA) were lost prior to 12-year follow-up, leaving 372 patients (390 THA) available for study.

Fully HAC coated stems were used in all patients. Clinical outcome was measured using Harris, Charnley Oxford, EuroQol EQ-5D scores. Radiographs were systematically analysed for implant position, loosening, migration, osteolysis. Polythene wear was digitally measured.

Mean age was 74.4 yrs. Dislocation occurred in 10 patients (3 recurrent). Revision operations were performed in nine patients (1.9%). Four acetabular revisions were performed for aseptic loosening. Other re-operations were for infection (3), periprosthetic fractures (1), cup malposition (1), revision of worn liner (3). The mean Harris and Oxford scores were 87 (78–97) and 19.1 (12–33) respectively. The Charnley score was 5.6 (5–6) for pain, 5.2 (4–6) for movement and 5.3 (4–6) for mobility. Migration of acetabular component was seen in 4 hips. Acetabular radiolucencies were present in 54 hips (9.7%). The mean linear polythene wear was 0.06mm/year. Mean inclination was 48.4 deg(38–65). Mean EQ-5D description scores and health thermometer scores were 0.81 (0.71–0.89) and 86 (64–95). With an end point of definite or probable loosening, the probability of survival at 12 years was 96.1%. Overall survival at 12 years with removal or repeat revision of either component for any reason as the end point was 94.2%.

The results of this study support the continued use of a fully coated prosthesis and documents the durability of the HAC coated components. In our clinical experience, the Furlong prosthesis revealed encouraging radiographic stability over a long term period


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 39 - 39
1 Jan 2011
Raman R Madhu T Hamilton R Shaw C Johnson G
Full Access

The aim of this study was to compare the clinical outcome, radiological outcome, activity level and functional outcome of hip resurfacing against metal on metal (MOM) hip arthroplasty.

Matched pairs of patients were selected from consecutive patients who had either MOM arthroplasty (n=236) or hip resurfacing (n=264). We matched 346 patients (173 pairs) in terms of age, sex, diagnosis, and a minimum follow up of 60 months. The functional outcome was assessed using Harris, Charnley-MDP, SF-36, UCLA and Tegner scores. Mean follow up was 67 months (61–80).

Mean age was 54.5 years. Femoral neck fractures were seen in 4 patients in the resurfacing group. The mean acetabular inclination was 42.8 deg and 44.3 deg in the resurfacing and MOM groups. Mean stem subsidence was 1.2mm. Bony ingrowth was seen in ninety six stems and all stems were stable by Engh s criterion. Radiolucent halo was observed around the stem of two resurfacing heads. The mean Harris hip score was 87.9 and 88.2 in the MOM and resurfacing groups respectively (p=0.76). The SF 36 score was 77.8 and 80.1 (p=0.4). The UCLA and Tegner scores were 6.1 and 3.6 for the resurfacing group and 5.9 and 3.9 for the MOM group. Nine patients in the resurfacing group had a postoperative painful limp which settled by 3 months. There was no radiological evidence of implant failure at last follow up. Survival at 5 years was 100% for the MOM group and 94.1% for the resurfacing group.

Functional outcome and activity levels increased in both groups with no difference between the groups. Post operative complications were fewer in MOM group and return to activity was quicker. It appears that resurfacing arthroplasty offers no medium term advantages over MOM arthroplasty. However longer follow up is required to establish the longevity and durability of this implant.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 389 - 389
1 Jul 2010
Madhu T Akula M Raman R Sharma H Johnson G
Full Access

The aim of the paper is to provide an independent single surgeon experience with BHR after a seven-year follow-up.

A cohort of 117 hips in 101 consecutive patients operated by the senior author between Jan 1998 and Dec 2002 were assessed to note their clinical, radiological and functional outcome after a mean follow-up of 7 years (5–9.4 years). Primary osteoarthritis was seen in 73 hips and secondary in 44 hips. Their mean age at surgery was 54 years (range 20–74years). At latest follow-up their mean flexion was 100°and their mean functional outcome scores were respectively: Oxford hip score of 21.5 (12–52, mode 12); Harris hip score of 84.8 (25–100, mode 97), Charnley modification of Merle d’ Aubigné and Postel scores were 4.8 for pain, 4.3 for walking and 5.4 for movement; and SF-36 (physical component 43.9 and mental component 51.45). Failure in the study was defined as revision for any reason. Revision was undertaken in 8 hips (6.8%), five within the first year for periprosthetic fracture neck of femur and 3 hips after the end of 5-year follow-up (2 for advance collapse of the femoral component in patients’ with avascular necrosis of the femoral head and 1 hip for sepsis).

The Kaplan-Meier survival with revision as end point at minimum 5-years of follow-up was 95.7% (95% CI 92–99%) and overall survival at an average 7-years was 91.7% (95% CI 86–97.6%). All the failures were due to the femoral component. However, the reported survival with the use of traditional uncemented and cemented femoral stems is beyond 99% at similar period of follow-up. Patient selection particularly in patients with secondary osteoarthritis is therefore a critical factor when choosing BHR components.