header advert
Results 1 - 10 of 10
Results per page:
Bone & Joint Research
Vol. 13, Issue 5 | Pages 214 - 225
3 May 2024
Groven RVM Kuik C Greven J Mert Ü Bouwman FG Poeze M Blokhuis TJ Huber-Lang M Hildebrand F Cillero-Pastor B van Griensven M

Aims

The aim of this study was to determine the fracture haematoma (fxH) proteome after multiple trauma using label-free proteomics, comparing two different fracture treatment strategies.

Methods

A porcine multiple trauma model was used in which two fracture treatment strategies were compared: early total care (ETC) and damage control orthopaedics (DCO). fxH was harvested and analyzed using liquid chromatography-tandem mass spectrometry. Per group, discriminating proteins were identified and protein interaction analyses were performed to further elucidate key biomolecular pathways in the early fracture healing phase.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 104 - 104
2 Jan 2024
der Broeck L Geurts J Qiu S Poeze M Blokhuis T
Full Access

The optimal treatment strategy for post-traumatic long bone non-unions is subject of an ongoing discussion. At the Maastricht University Medical Center (MUMC+) the induced membrane technique is used to treat post-traumatic long bone non-unions. This technique uses a multimodal treatment algorithm involving bone marrow aspirate concentrate (BMAC), the reamer-irrigator-aspirator (RIA) and P-15 bioactive peptide (iFactor, Cerapedics). Bioactive glass (S53P4 BAG, Bonalive) is added when infection is suspected. This study aims to objectify the effect of this treatment algorithm on the health-related quality of life (HRQoL) of patients with post-traumatic long bone non-unions. We hypothesized that HRQoL would improve after treatment.

From January 2020 to March 2023, consecutive patients who were referred to a multidisciplinary (trauma, orthopaedic and plastic surgery) non-union clinic at the MUMC+, The Netherlands, were evaluated using the Non-Union Scoring System (NUSS). The EQ-5D-5L questionnaire and the Lower Extremity Functional Scale (LEFS) were employed to obtain HRQoL outcomes both prior to and subsequent to surgery, with a follow-up at 6, 18 and 35 weeks.

Seventy-six patients were assessed at baseline (T0), with a mean NUSS of 40 (± 13 SD). Thirty-eight patients had their first follow-up, six weeks after surgery (T1). Thirty-one patients had a second follow-up at 18 weeks (T2), and twenty patients had the third follow-up at 35 weeks (T3). The EQ-5D index mean at baseline was 0.480, followed by an index of 0.618 at T1, 0.636 at T2, and 0.702 at T3. A significant difference was found in the HRQoL score between T0 and T1, as well as T2 and T3 (p<0.001; p=0.011). The mean LEFS significantly increased from 26 before intervention to 34, 39, and 43 after treatment (p<0.001; p=0.033; p=0.016).

This study demonstrated a significant improvement in the health-related quality of life of patients with post-traumatic long bone non-unions after the standardized treatment algorithm following the induced membrane technique.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 61 - 61
17 Apr 2023
Lodewijks L Blokhuis T Poeze M
Full Access

The need for an artificial scaffold in very large bone defects is clear, not only to limit the risk of graft harvesting, but also to improve clinical success. The use of custom osteoconductive scaffolds made from biodegradable polyester and ceramics can be a valuable patient friendly option, especially in case of a concomitant infection.

Multiple types of scaffolds for the Masquelet procedure (MP) are available, however these frequently demonstrate central graft involution when defects exceed a certain size and the complication rates remains high. This paper describes three infected tibial defect nonunions with a segmental defect over ten centimeters long treated with a customized 3D printed polycaprolactone-tricalcium phosphate (PCL-TCP) cage in combination with biological adjuncts.

Three male patients, between the age of 37 and 47, were treated for an infected tibial defect nonunion after sustaining Gustilo grade 3 open fractures. All had a segmental midshaft bone defect of more than ten centimeters (range 11–15cm). First stage MPs consisted of extensive debridement, external fixation and placement of anterior lateral thigh flaps (ALT). Positive cultures were obtained from all patients during this first stage, that were treated with specific systemic antibiotics during 12 weeks. The second stage MP was carried out at least two months after the first stage. CT scans were obtained after the first stage to manufacture defect-specific cages. In the final procedure a custom 3D printed PCL-TCP cage (Osteopore, Singapore) was placed in the defect in combination with biological adjuncts (BMAC, RIA derived autograft, iFactor and BioActive Glass). Bridging of the defect, assessed at six months by CT, was achieved in all cases. SPECT-scans 6 months post-operatively demonstrated active bone regeneration, also involving the central part of the scaffold. All three patients regained function and reported less pain with full weight-bearing.

This case report shows that 3D printed PCL-TCP cages in combination with biological adjuncts is a novel addition to the surgical treatment of very large bone defects in (infected) posttraumatic nonunion of the tibia. This combination could overcome some of the current drawbacks in this challenging indication.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 13 - 13
4 Apr 2023
Meesters D Groven R Wijnands N Poeze M
Full Access

Nitric oxide is a free radical which in vivo is solely produced during the conversion of the amino acid arginine into citrulline by nitric oxide synthase enzymes. Recently, the importance of nitric oxide on inflammation and bone metabolism has been investigated. However, the knowledge regarding possible in vitro effects of arginine supplementation on chondrogenic differentiation is limited.

ATDC5, a cell line which is derived from mouse teratocarcinoma cells and which is characterized as chondrogenic cell line, were proliferated in Dulbecco's Modified Eagle Medium (DMEM)/F12 and subsequently differentiated in proliferation medium supplemented with insulin, transferrin and sodium-selenite and where arginine was added in four different concentrations (0, 7.5, 15 and 30 mM). Samples were harvested after 7 or 10 days and were stored at −80 °C for subsequent RNA isolation for qPCR analysis. To determine chondrogenic differentiation, Alcian Blue staining was performed to stain the proteoglycan aggrecan, which is secreted by differentiated ATDC5 cells. All measurements were performed in triplo.

Alcian Blue staining showed a qualitative increase of proteoglycan aggrecan secretion in differentiated ATDC5 cells after treatment with 7 and 15 mM arginine, with additional increased expression of ColII, ColX, Bmp4 and Bmp6. Treatment with 30 mM arginine inhibited chondrogenic differentiation and expression of aforementioned genes, however, Cox-2 and Vegfa gene expression were increased in these samples. Bmp7 was not significantly expressed in any experimental condition.

The obtained results are suggestive for a dose-dependent effect of arginine supplementation on chondrogenic differentiation and associated gene expression, with 7.5 and 15 mM as most optimal concentrations and implications for apoptosis after incubation with 30 mM arginine. A future recommendation would be to investigate the effects of citrulline in a similar experiment, as this shows even more promising results to enhance the nitric oxide metabolism in sepsis and bone healing.


Bone & Joint Open
Vol. 2, Issue 10 | Pages 842 - 849
13 Oct 2021
van den Boom NAC Stollenwerck GANL Lodewijks L Bransen J Evers SMAA Poeze M

Aims

This systematic review and meta-analysis was conducted to compare open reduction and internal fixation (ORIF) with primary arthrodesis (PA) in the treatment of Lisfranc injuries, regarding patient-reported outcome measures (PROMs), and risk of secondary surgery. The aim was to conclusively determine the best available treatment based on the most complete and recent evidence available.

Methods

A systematic search was conducted in PubMed, Cochrane Controlled Register of Trials (CENTRAL), EMBASE, CINAHL, PEDro, and SPORTDiscus. Additionally, ongoing trial registers and reference lists of included articles were screened. Risk of bias (RoB) and level of evidence were assessed using the Cochrane risk of bias tools and the Grading of Recommendations Assessment, Development and Evaluation (GRADE) tool. The random and fixed-effect models were used for the statistical analysis.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1697 - 1702
1 Dec 2020
Schormans PMJ Kooijman MA Ten Bosch JA Poeze M Hannemann PFW

Aims

Fixation of scaphoid nonunion with a volar locking plate and cancellous bone grafting has been shown to be a successful technique in small series. Few mid- or long-term follow-up studies have been reported. The aim of this study was to report the mid-term radiological and functional outcome of plate fixation for scaphoid nonunion.

Methods

Patients with a scaphoid nonunion were prospectively enrolled and treated with open reduction using a volar approach, debridement of the nonunion, and fixation using a locking plate and cancellous bone grafting, from the ipsilateral iliac crest. Follow-up included examination, functional assessment using the patient-rated wrist/hand evaluation (PRWHE), and multiplanar reformation CT scans at three-month intervals until union was confirmed.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 478 - 484
1 Apr 2020
Daniels AM Wyers CE Janzing HMJ Sassen S Loeffen D Kaarsemaker S van Rietbergen B Hannemann PFW Poeze M van den Bergh JP

Aims

Besides conventional radiographs, the use of MRI, CT, and bone scintigraphy is frequent in the diagnosis of a fracture of the scaphoid. However, which techniques give the best results remain unknown. The investigation of a new imaging technique initially requires an analysis of its precision. The primary aim of this study was to investigate the interobserver agreement of high-resolution peripheral quantitative CT (HR-pQCT) in the diagnosis of a scaphoid fracture. A secondary aim was to investigate the interobserver agreement for the presence of other fractures and for the classification of scaphoid fracture.

Methods

Two radiologists and two orthopaedic trauma surgeons evaluated HR-pQCT scans of 31 patients with a clinically-suspected scaphoid fracture. The observers were asked to determine the presence of a scaphoid or other fracture and to classify the scaphoid fracture based on the Herbert classification system. Fleiss kappa statistics were used to calculate the interobserver agreement for the diagnosis of a fracture. Intraclass correlation coefficients (ICCs) were used to assess the agreement for the classification of scaphoid fracture.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 35 - 35
1 Jan 2017
Stevens J Wiltox A Meijer K Bijnens W Poeze M
Full Access

Osteoarthritis of the first metatarsophalangeal (MTP1) joint is a common disorder in elderly, resulting in pain and disability. Arthrodesis of this joint shows satisfactory results, with relieve of pain in approximately 85% of the patients. However, the compensation mechanism for loss of motion in the MTP1 joint after MTP1 arthrodesis is unknown. A reduced compensation mechanism of the foot may explain the disappointing result of MTP1 arthrodesis in the remaining 15% of the patients. This study was conducted to elucidate this compensation mechanism. We hypothesize that the ankle and forefoot are responsible for compensation after MTP1 arthrodesis.

Gait was evaluated in eight patients with arthrodesis of the MTP1 joint (10 feet) and twelve healthy controls (21 feet) by using a sixteen-camera Vicon-system. The four-segmental, validated Oxford-Foot-Model was used to investigate differences in range of motion of the hindfoot-tibia, forefoot-hindfoot and hallux-forefoot segment during stance. For statistical analysis, the unpaired t-test with Bonferroni correction (p<0.0125) was performed.

No differences in spatiotemporal parameters were observed between both groups. In the frontal plane, MTP1 arthrodesis decreased the range of motion in midstance, while an increased range of motion was observed in terminal stance for the hindfoot relative to the tibia in the transversal plane. Subsequently range of motion in the forefoot in preswing was increased. This resulted in less eversion in the hindfoot during midstance, increased internal rotation of the hindfoot during terminal stance and more supination in the forefoot during preswing in the MTP1 arthrodesis group. Motion of the hallux was restricted in the loading response (i.e. plantar flexion) and terminal stance (i.e. dorsiflexion).

As hypothesized, both the ankle and the forefoot are responsible for compensation after MTP1 arthrodesis, because arthrodesis causes less eversion and increased internal rotation of the hindfoot and increased supination of the forefoot. As expected, both dorsiflexion and plantar flexion of the hallux was restricted due to arthrodesis. These findings suggest a gait pattern in which the lateral arch of the foot is more loaded and the stiff hallux is avoided during the stance phase of gait.

Our results indicate that proper motion of the forefoot and ankle joint is important when considering arthrodesis of the MTP1 joint. Therefore, we emphasize careful assessment the range of motion in the forefoot and ankle joint in the pre-operative situation, since patients with a decreased range of motion in the forefoot and ankle joint have a less functioning compensation mechanism. We currently perform a study to evaluate the strength of the positive correlation between the pre-operative range of motion in the forefoot and ankle joint and the clinical outcome.


The Bone & Joint Journal
Vol. 96-B, Issue 8 | Pages 1070 - 1076
1 Aug 2014
Hannemann PFW van Wezenbeek MR Kolkman KA Twiss ELL Berghmans CHJ Dirven PAMGM Brink PRG Poeze M

We hypothesised that the use of pulsed electromagnetic field (PEMF) bone growth stimulation in acute scaphoid fractures would significantly shorten the time to union and reduce the number of nonunions in a randomised, double-blind, placebo-controlled multicentre trial. A total of 102 patients (78 male, 24 female; mean age 35 years (18 to 77)) from five different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly allocated to PEMF (n = 51) or placebo (n = 51) and assessed with regard to functional and radiological outcomes (multiplanar reconstructed CT scans) at 6, 9, 12, 24 and 52 weeks. The overall time to clinical and radiological healing did not differ significantly between the active PEMF group and the placebo group. We concluded that the addition of PEMF bone growth stimulation to the conservative treatment of acute scaphoid fractures does not accelerate bone healing.

Cite this article: Bone Joint J 2014; 96-B:1070–6.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1403 - 1408
1 Oct 2012
Hannemann PFW Göttgens KWA van Wely BJ Kolkman KA Werre AJ Poeze M Brink PRG

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks.

A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group.

We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures.