header advert
Results 1 - 50 of 69
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims

There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation.

Methods

We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75).


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 140 - 140
1 May 2024
Morlock M Perka C Melsheimer O Kirschbaum SM


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 130 - 136
1 Mar 2024
Morlock M Perka C Melsheimer O Kirschbaum SM

Aims

Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients.

Methods

A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 48 - 48
24 Nov 2023
Dos Santos MV Meller S Perka C Trampuz A Renz N
Full Access

Aim

Antimicrobial suppression has shown to significantly improve treatment success of streptococcal periprosthetic joint infection (PJI) compared to 12-week standard antimicrobial therapy, however, only short-term follow-up was investigated. In this study we assessed the impact of suppression on the long-term outcome of streptococcal PJI.

Method

Consecutive patients with streptococcal PJI (defined by EBJIS criteria) treated 2009–2021 were prospectively included and allocated into standard and suppression (> 6 months) treatment group. Infection-free survival was assessed with Kaplan-Meier-method and compared between the groups with log rank test. Rates of infection-free, streptococcal infection-free and relapse-free status as well as tolerability of suppression were assessed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 26 - 26
24 Nov 2023
Morovic P Benavente LP Karbysheva S Perka C Trampuz A
Full Access

Aim

Antibiotics have limited activity in the treatment of multidrug-resistant or chronic biofilm-associated infections, in particular when implants cannot be removed. Lytic bacteriophages can rapidly and selectively kill bacteria, and can be combined with antibiotics. However, clinical experience in patients with surgical infections is limited. We investigated the outcome and safety of local application of bacteriophages in addition to antimicrobial therapy.

Method

8 patients (2 female and 6 male) with complex orthopedic and cardiovascular infections were included, in whom standard treatment was not feasible or impossible. The treatment was performed in agreement with the Article 37 of the Declaration of Helsinki. Commercial or individually prepared bacteriophages were provided by ELIAVA Institute in Tbilisi, Georgia. Bacteriophages were applied during surgery and continued through drains placed during surgery three times per day for the following 5–14 days. Follow-up ranged from 1 to 28 months.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 832 - 838
3 Nov 2023
Pichler L Li Z Khakzad T Perka C Pumberger M Schömig F

Aims

Implant-related postoperative spondylodiscitis (IPOS) is a severe complication in spine surgery and is associated with high morbidity and mortality. With growing knowledge in the field of periprosthetic joint infection (PJI), equivalent investigations towards the management of implant-related infections of the spine are indispensable. To our knowledge, this study provides the largest description of cases of IPOS to date.

Methods

Patients treated for IPOS from January 2006 to December 2020 were included. Patient demographics, parameters upon admission and discharge, radiological imaging, and microbiological results were retrieved from medical records. CT and MRI were analyzed for epidural, paravertebral, and intervertebral abscess formation, vertebral destruction, and endplate involvement. Pathogens were identified by CT-guided or intraoperative biopsy, intraoperative tissue sampling, or implant sonication.


Aims

Total knee arthroplasty (TKA) may provoke ankle symptoms. The aim of this study was to validate the impact of the preoperative mechanical tibiofemoral angle (mTFA), the talar tilt (TT) on ankle symptoms after TKA, and assess changes in the range of motion (ROM) of the subtalar joint, foot posture, and ankle laxity.

Methods

Patients who underwent TKA from September 2020 to September 2021 were prospectively included. Inclusion criteria were primary end-stage osteoarthritis (Kellgren-Lawrence stage IV) of the knee. Exclusion criteria were missed follow-up visit, post-traumatic pathologies of the foot, and neurological disorders. Radiological angles measured included the mTFA, hindfoot alignment view angle, and TT. The Foot Function Index (FFI) score was assessed. Gait analyses were conducted to measure mediolateral changes of the gait line and ankle laxity was tested using an ankle arthrometer. All parameters were acquired one week pre- and three months postoperatively.


Bone & Joint Open
Vol. 4, Issue 10 | Pages 758 - 765
12 Oct 2023
Wagener N Löchel J Hipfl C Perka C Hardt S Leopold VJ

Aims

Psychological status may be an important predictor of outcome after periacetabular osteotomy (PAO). The aim of this study was to investigate the influence of psychological distress on postoperative health-related quality of life, joint function, self-assessed pain, and sports ability in patients undergoing PAO.

Methods

In all, 202 consecutive patients who underwent PAO for developmental dysplasia of the hip (DDH) at our institution from 2015 to 2017 were included and followed up at 63 months (SD 10) postoperatively. Of these, 101 with complete data sets entered final analysis. Patients were assessed by questionnaire. Psychological status was measured by Brief Symptom Inventory (BSI-18), health-related quality of life was raised with 36-Item Short Form Survey (SF-36), hip functionality was measured by the short version 0f the International Hip Outcome Tool (iHOT-12), Subjective Hip Value (SHV), and Hip Disability and Outcome Score (HOS). Surgery satisfaction and pain were assessed. Dependent variables (endpoints) were postoperative quality of life (SF-36, HOS quality of life (QoL)), joint function (iHOT-12, SHV, HOS), patient satisfaction, and pain. Psychological distress was assessed by the Global Severity Index (GSI), somatization (BSI Soma), depression (BSI Depr), and anxiety (BSI Anx). Influence of psychological status was assessed by means of univariate and multiple multivariate regression analysis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 44 - 44
23 Jun 2023
Scholz J Perka C Hipfl C
Full Access

Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation.

We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103).

DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types.

Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 80 - 80
1 Oct 2022
Morovic P Karbysheva S Meller S Kirschbaum S Perka C Conen A Trampuz A
Full Access

Aim

Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA.

Method

Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity.


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 801 - 810
1 Jul 2022
Krull P Steinbrück A Grimberg AW Melsheimer O Morlock M Perka C

Aims

Registry studies on modified acetabular polyethylene (PE) liner designs are limited. We investigated the influence of standard and modified PE acetabular liner designs on the revision rate for mechanical complications in primary cementless total hip arthroplasty (THA).

Methods

We analyzed 151,096 primary cementless THAs from the German Arthroplasty Registry (EPRD) between November 2012 and November 2020. Cumulative incidence of revision for mechanical complications for standard and four modified PE liners (lipped, offset, angulated/offset, and angulated) was determined using competing risk analysis at one and seven years. Confounders were investigated with a Cox proportional-hazards model.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 28 - 28
1 Nov 2021
Perka C Krull P Steinbrück A Morlock M
Full Access

Special acetabular polyethylene (PE) liners are intended to increase the stability of the artificial hip joint, yet registry studies on them are limited. The pupose of this study was to investigate differences in revision rates for mechanical complications in primary cementless total hip arthroplasty (THA) with standard and special PE acetabular liners in patients with ostheoarthritis.

Data from the German Arthroplasty Registry (EPRD) between 2012 until 2020 were analysed. Patients with diagnosed ostheoarthritis of the hip without relevant prior surgeries, who received a primary cementless THA with a ceramic/PE bearing articulation were included. Cumulative incidences of revision for mechanical complications for Standard and 4 special PE liners (Lipped, Increased Offset, Angulated, Angulated|Increased Offset) were determined using the Kaplan-Meier Estimator. Confounding factors were investigated with a Cox proportional-hazards model.

In total 151.104 cases were included. 7-year unadjusted revision-free survival for mechanical complications compared to Standard liners (97.7%) was lower for Angulated (97.4%), Lipped (97.2%) and Angulated|Increased Offset liners (94.7%), but higher for Increased Offset liners (98.1%). Risk of revision for mechanical complications was not significantly different between Standard, Lipped and Angulated liners. Increased Offset liners (HR=0.68; 95% CI=0.5–0.92) reduced, while Angulated|Increased Offset liners (HR= 1.81; 95% CI=1.38–2.36) increased the risk. Higher age at admission and an Elixhauser comorbidity index greater zero increased the risk, whereas a larger liner share slightly reduced the risk.

Only the use of Increased Offset liners reduced the risk of revision for mechanical complications compared to Standard liners — other special liners did not.


Bone & Joint Open
Vol. 2, Issue 8 | Pages 576 - 582
2 Aug 2021
Fuchs M Kirchhoff F Reichel H Perka C Faschingbauer M Gwinner C

Aims

Current guidelines consider analyses of joint aspirates, including leucocyte cell count (LC) and polymorphonuclear percentage (PMN%) as a diagnostic mainstay of periprosthetic joint infection (PJI). It is unclear if these parameters are subject to a certain degree of variability over time. Therefore, the aim of this study was to evaluate the variation of LC and PMN% in patients with aseptic revision total knee arthroplasty (TKA).

Methods

We conducted a prospective, double-centre study of 40 patients with 40 knee joints. Patients underwent joint aspiration at two different time points with a maximum period of 120 days in between these interventions and without any events such as other joint aspirations or surgeries. The main indications for TKA revision surgery were aseptic implant loosening (n = 24) and joint instability (n = 11).


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1070 - 1077
1 Jun 2021
Hipfl C Mooij W Perka C Hardt S Wassilew GI

Aims

The purpose of this study was to evaluate unexpected positive cultures in total hip arthroplasty (THA) revisions for presumed aseptic loosening, to assess the prevalence of low-grade infection using two definition criteria, and to analyze its impact on implant survival after revision.

Methods

A total of 274 THA revisions performed for presumed aseptic loosening from 2012 to 2016 were reviewed. In addition to obtaining intraoperative tissue cultures from all patients, synovial and sonication fluid samples of the removed implant were obtained in 215 cases (79%) and 101 cases (37%), respectively. Histopathological analysis was performed in 250 cases (91%). Patients were classified as having low-grade infections according to institutional criteria and Musculoskeletal Infection Society (MSIS) International Consensus Meeting (ICM) 2013 criteria. Low-grade infections according to institutional criteria were treated with targeted antibiotics for six weeks postoperatively. Implant failure was defined as the need for re-revision resulting from periprosthetic joint infection (PJI) and aseptic reasons. The mean follow-up was 68 months (26 to 95).


Bone & Joint Open
Vol. 2, Issue 5 | Pages 344 - 350
31 May 2021
Ahmad SS Hoos L Perka C Stöckle U Braun KF Konrads C

Aims

The follow-up interval of a study represents an important aspect that is frequently mentioned in the title of the manuscript. Authors arbitrarily define whether the follow-up of their study is short-, mid-, or long-term. There is no clear consensus in that regard and definitions show a large range of variation. It was therefore the aim of this study to systematically identify clinical research published in high-impact orthopaedic journals in the last five years and extract follow-up information to deduce corresponding evidence-based definitions of short-, mid-, and long-term follow-up.

Methods

A systematic literature search was performed to identify papers published in the six highest ranked orthopaedic journals during the years 2015 to 2019. Follow-up intervals were analyzed. Each article was assigned to a corresponding subspecialty field: sports traumatology, knee arthroplasty and reconstruction, hip-preserving surgery, hip arthroplasty, shoulder and elbow arthroplasty, hand and wrist, foot and ankle, paediatric orthopaedics, orthopaedic trauma, spine, and tumour. Mean follow-up data were tabulated for the corresponding subspecialty fields. Comparison between means was conducted using analysis of variance.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 899 - 903
1 Jul 2020
Bürger J Palmowski Y Strube P Perka C Putzier M Pumberger M

Aims

To evaluate the histopathological examination of peri-implant tissue samples as a technique in the diagnosis of postoperative spinal implant infection (PSII).

Methods

This was a retrospective analysis. Patients who underwent revision spinal surgery at our institution were recruited for this study. PSII was diagnosed by clinical signs, histopathology, and microbiological examination of intraoperatively collected samples. Histopathology was defined as the gold standard. The sensitivity for histopathology was calculated. A total of 47 patients with PSII and at least one microbiological and histopathological sample were included in the study.


The Bone & Joint Journal
Vol. 102-B, Issue 5 | Pages 573 - 579
1 May 2020
Krueger DR Guenther K Deml MC Perka C

Aims

We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed.

Methods

All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 311 - 316
1 Mar 2019
Löchel J Janz V Hipfl C Perka C Wassilew GI

Aims

The use of trabecular metal (TM) shells supported by augments has provided good mid-term results after revision total hip arthroplasty (THA) in patients with a bony defect of the acetabulum. The aim of this study was to assess the long-term implant survivorship and radiological and clinical outcomes after acetabular revision using this technique.

Patients and Methods

Between 2006 and 2010, 60 patients (62 hips) underwent acetabular revision using a combination of a TM shell and augment. A total of 51 patients (53 hips) had complete follow-up at a minimum of seven years and were included in the study. Of these patients, 15 were men (29.4%) and 36 were women (70.6%). Their mean age at the time of revision THA was 64.6 years (28 to 85). Three patients (5.2%) had a Paprosky IIA defect, 13 (24.5%) had a type IIB defect, six (11.3%) had a type IIC defect, 22 (41.5%) had a type IIIA defect, and nine (17%) had a type IIIB defect. Five patients (9.4%) also had pelvic discontinuity.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 132 - 139
1 Feb 2019
Karczewski D Winkler T Renz N Trampuz A Lieb E Perka C Müller M

Aims

In 2013, we introduced a specialized, centralized, and interdisciplinary team in our institution that applied a standardized diagnostic and treatment algorithm for the management of prosthetic joint infections (PJIs). The hypothesis for this study was that the outcome of treatment would be improved using this approach.

Patients and Methods

In a retrospective analysis with a standard postoperative follow-up, 95 patients with a PJI of the hip and knee who were treated with a two-stage exchange between 2013 and 2017 formed the study group. A historical cohort of 86 patients treated between 2009 and 2011 not according to the standardized protocol served as a control group. The success of treatment was defined according to the Delphi criteria in a two-year follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 58 - 58
1 Dec 2018
Sigmund IK Önder N Winkler T Perka C Trampuz A Renz N
Full Access

Aim

Two stage revision is the most commonly used surgical treatment strategy for periprosthetic hip infections (PHI). The aim of our study was to assess the intra- and postoperative complications during and after two stage revision using resection arthroplasty between ex- and reimplantation.

Method

In this retrospective cohort study, all patients treated with a two stage revision using resection arthroplasty for PHI were included from 2008 to 2014. During the first stage, the prosthesis was removed resulting in a resection arthroplasty without the use a PMMA spacer. During second stage, (cemented or uncemented) reimplantation of the hip prosthesis was performed. The cohort was stratified into two groups according to the length of prosthesis-free interval (≤10 weeks and >10 weeks). Data on complications during explantation, prosthesis-free interval, reimplantation, and after reimplantation was collected. The overall complication rate between both groups was compared using the chi-squared test. The revision-free and infection-free survival was estimated using Kaplan-Meier survival analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 10 - 10
1 Dec 2018
Renz N Trebse R Akgün D Perka C Trampuz A
Full Access

Aim

Treatment of enterococcal periprosthetic joint infections (PJI) is challenging due to heterogeneous pathogenesis, non-standardized management strategies and lack of biofilm-active antibiotics. Previous studies report treatment success from 50–76%. We evaluated the characteristics and outcome of enterococcal PJI, in particular the influence of antimicrobial treatment regimens.

Method

Consecutive patients with enterococcal PJI treated at two specialized orthopaedic institutions were retrospectively included from 2010 to 2017. PJI was defined by the proposed European Bone and Joint Infection Society (EBJIS) criteria. Adequate antimicrobial treatment was considered when the antibiotic was appropiate for the treatment of enterococcal bone infections (activity, dose, oral bioavailability, bone penetration). The treatment success (defined as no relapse of enteroccal infection) and clinical success(i.e. infection-free status) was evaluated and compared using Fishers exact test.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1482 - 1486
1 Nov 2018
Akgün D Müller M Perka C Winkler T

Aims

The aim of this study was to determine the prevalence and characteristics of C-reactive protein (CRP)-negative prosthetic joint infection (PJI) and evaluate the influence of the type of infecting organism on the CRP level.

Patients and Methods

A retrospective analysis of all PJIs affecting the hip or knee that were diagnosed in our institution between March 2013 and December 2016 was performed. A total of 215 patients were included. Their mean age was 71 years (sd 11) and there were 118 women (55%). The median serum CRP levels were calculated for various species of organism and for patients with acute postoperative, acute haematogenous, and chronic infections. These were compared using the Kruskal–Wallis test, adjusting for multiple comparisons with Dunn’s test. The correlation between the number of positive cultures and serum CRP levels was estimated using Spearman correlation coefficient.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1442 - 1448
1 Nov 2018
Hipfl C Janz V Löchel J Perka C Wassilew GI

Aims

Severe acetabular bone loss and pelvic discontinuity (PD) present particular challenges in revision total hip arthroplasty. To deal with such complex situations, cup-cage reconstruction has emerged as an option for treating this situation. We aimed to examine our success in using this technique for these anatomical problems.

Patients and Methods

We undertook a retrospective, single-centre series of 35 hips in 34 patients (seven male, 27 female) treated with a cup-cage construct using a trabecular metal shell in conjunction with a titanium cage, for severe acetabular bone loss between 2011 and 2015. The mean age at the time of surgery was 70 years (42 to 85) and all patients had an acetabular defect graded as Paprosky Type 2C through to 3B, with 24 hips (69%) having PD. The mean follow-up was 47 months (25 to 84).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 20 - 20
1 Jan 2018
Renz N Mudrovcic S Trampuz A Perka C
Full Access

Cutibacterium species (formerly Propionibacterium species) are increasingly recognized as causative pathogens of low-grade periprosthetic joint infections (PJI). The clinical manifestation of infections caused by this low virulent microorganism is nonspecific and the interpretation remains challenging. In this prospective cohort study from 01/2012 to 07/2017 we analyzed the clinical and diagnostic characteristics of microbiologically proven hip PJI caused by Cutibacterium species. PJI was defined by growth of Cutibacteria in ≥2 periprosthetic tissue samples or in sonication fluid of the removed implant (>50 CFU/ml) at revision surgery. If Cutibacteria grew only in synovial fluid at least one other positive microbiological specimen or non-microbiological criterion was required.

We included 26 patients suffering from Cutibacterium hip PJI, among them 19 were males (73%). The majority of PJI (24, 92%) presented delayed (3–24 months) or late (>24 months) after implantation. Sinus tract was present in 4 patients (16%) and radiological implant loosening in 16 patients (62%). Among non-microbiological diagnostic tests, increased synovial fluid leukocyte count showed the highest sensitivity (82%), followed by tissue histology (71%) and serum C-reactive protein (58%). After 7 days of incubation Cutibacterium grew in synovial fluid, periprosthetic tissue and sonication fluid culture in 20%, 42% and 32%, respectively, and in 43%, 76% and 83%, respectively, after 14 days of incubation.

We conclude that Cutibacterium PJI was diagnosed late in the disease course and presented with subtle clinical signs. Prolonged culture incubation and implant sonication improved the poor performance of conventional microbiological tests. Due to lack of reliable diagnostic tests, Cutibacterium remains difficult to detect making the diagnosis challenging.


The Bone & Joint Journal
Vol. 99-B, Issue 12 | Pages 1584 - 1589
1 Dec 2017
Wassilew GI Heller MO Janz V Perka C Müller M Renner L

Aims

This study sought to establish the prevalence of the cross over sign (COS) and posterior wall sign (PWS) in relation to the anterior pelvic plane (APP) in an asymptomatic population through reliable and accurate 3D-CT based assessment.

Materials and Methods

Data from pelvic CT scans of 100 asymptomatic subjects (200 hips) undertaken for conditions unrelated to disorders of the hip were available for analysis in this study. A previously established 3D analysis method was applied to assess the prevalence of the COS and PWS in relation to the APP.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 53 - 53
1 Dec 2017
Akgün D Rakow A Perka C Trampuz A Renz N
Full Access

Background

Periprosthetic joint infections (PJI), caused by pathogens, for which no biofilm-active antibiotics are available, are often referred to as difficult-to-treat (DTT). It is unclear whether DTT PJI has worse outcome due to unavailability of biofilm-active antibiotics. We evaluated the outcome of DTT and non-DTT PJI managed according to a standardized treatment regimen.

Methods

Patients with hip and knee PJI from 2013 to 2015 were prospectively included and followed-up for ≥2 years. DTT PJI was defined as growth of microorganism(s) resistant to biofilm-active antibiotics. The Kaplan-Meier survival analysis was used to compare the probability of infection-free survival between DTT and non-DTT PJI.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 76 - 76
1 Dec 2017
Renz N Mudrovcic S Perka C Trampuz A
Full Access

Aim

To assess the clinical characteristics, diagnostic tests and treatment strategies in orthopedic implant-associated infections (OIAI) caused by Cutibacterium spp.

Method

We retrospectively included consecutive patients with OIAI caused by Cutibacterium spp. treated at our institution from January 2012 to January 2017. OIAI was diagnosed when: (i) macroscopic purulence, sinus tract or exposed implant was present; (ii) acute inflammation in peri-implant-tissue was documented; (iii) Cutibacterium spp. grew in joint aspirate, ≥2 intraoperative peri-implant tissue samples or in sonication fluid of the removed implant (>50 CFU/ml).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 84 - 84
1 Dec 2017
Rakow A Perka C Akgün D Schütz M Trampuz A Renz N
Full Access

Aim

The incidence of hematogenous periprosthetic joint infections (hPJI) is unknown and the cases probably largely underreported. Unrecognized and untreated primary infectious foci may cause continuous bacteremia, further spread of microorganisms and thus treatment failure or relapse of infection. This study aimed at improving knowledge about primary foci and microbiological characteristics of this entity to establish preventive measures and improve diagnostic and therapeutic strategies to counteract hPJI.

Method

We retrospectively analysed all consecutive patients with hPJI, who were treated at our institution from January 2010 until December 2016. Diagnosis of PJI was established if 1 of the following criteria applied:(i) macroscopic purulence, (ii) presence of sinus tract, (iii) positive cytology of joint aspirate (>2000 leukocytes/μl or >70% granulocytes), (iv) significant microbial growth in synovial fluid, periprosthetic tissue or sonication culture of retrieved prosthesis components, (v) positive histopathology. PJI was classified as hematogenous if the following criteria were fulfilled additionally: (1) onset of symptoms more than 1 month after arthroplasty AND (2) i) isolation of the same organism in blood cultures OR ii) evidence of a distant infectious focus consistent with the pathogen.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 19 - 19
1 Dec 2017
Renz N Yermak K Perka C Trampuz A
Full Access

Aim

The aim of the study was to assess the accuracy of the alpha defensin lateral flow test for diagnosis of periprosthetic joint infection (PJI) using an optimized diagnostic algorithm and three classification systems. In addition, we compared the performance with synovial fluid leukocyte count, the most sensitive preoperative test.

Method

In this prospective multicenter study we included all consecutive patients with painful prosthetic hip and knee joints undergoing diagnostic joint aspiration. Alpha defensin lateral flow test was used according to manufacturer instructions. The following diagnostic criteria were used to confirm infection: Musculoskeletal Infection Society (MSIS), Infectious Diseases Society of America (IDSA) and Swiss orthopedics and Swiss Society of Infectious Diseases (SOSSID). In the latter, PJI was confirmed when at least one of following criteria applied: macroscopic purulence, sinus tract, positive cytology of joint aspirate (>2000 leukocytes/μl or >70% granulocytes), histological proof of acute inflammation in periprosthetic tissue, positive culture (from aspirate, tissue or sonication fluid). Infection was classified as chronic, if symptom duration was more than 3 weeks or if infection manifested after more than 1 month after surgery. The sensitivity and specificity of the alpha defensin lateral flow test and leukocyte count in synovial fluid were calculated and compared using McNemar Chi-square test.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1490 - 1495
1 Nov 2017
Akgün D Müller M Perka C Winkler T

Aims

The aim of this study was to identify the incidence of positive cultures during the second stage of a two-stage revision arthroplasty and to analyse the association between positive cultures and an infection-free outcome.

Patients and Methods

This single-centre retrospective review of prospectively collected data included patients with a periprosthetic joint infection (PJI) of either the hip or the knee between 2013 and 2015, who were treated using a standardised diagnostic and therapeutic algorithm with two-stage exchange. Failure of treatment was assessed according to a definition determined by a Delphi-based consensus. Logistic regression analysis was performed to assess the predictors of positive culture and risk factors for failure. The mean follow-up was 33 months (24 to 48).


The Bone & Joint Journal
Vol. 99-B, Issue 7 | Pages 921 - 926
1 Jul 2017
Märdian S Perka C Schaser K Gruner J Scheel F Schwabe P

Aims

Periprosthetic fracture is a significant complication of total hip and knee arthroplasty. This study aimed to describe the survival of patients sustaining periprosthetic femoral fractures and compare this with that of the general population, as well as to identify the factors that influence survival.

Patients and Methods

A total of 151 patients (women: men 116:35, mean age 74.6 years, standard deviation 11.5) that sustained a periprosthetic fracture between January 2005 and October 2012 were retrospectively analysed. Epidemiological data, comorbidities, type of surgical management, type of implant, and mortality data were studied.


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 653 - 659
1 May 2017
Akgün D Trampuz A Perka C Renz N

Aims

To investigate the outcomes of treatment of streptococcal periprosthetic joint infection (PJI) involving total knee and hip arthroplasties.

Patients and Methods

Streptococcal PJI episodes which occurred between January 2009 and December 2015 were identified from clinical databases. Presentation and clinical outcomes for 30 streptococcal PJIs in 30 patients (12 hip and 18 knee arthroplasties) following treatment were evaluated from the medical notes and at review. The Kaplan-Meier survival method was used to estimate the probability of infection-free survival. The influence of the biofilm active antibiotic rifampin was also assessed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 102 - 102
1 Mar 2017
Rakow A Schoon J Dienelt A John T Textor M Duda G Perka C Schulze F Ode A
Full Access

INTRODUCTION

The uncertainty of the biological effects of wear and corrosion from Metal-on-metal (MoM) implants has initiated a debate on their safety and use. Generally, the release of wear particles from MoM hip implants can clinically manifest in aseptic osteolysis. In our study, the effect of MoM-wear particles and particle originated Co and Cr ions on mesenchymal stromal cells (MSCs) was investigated [1]. The lead hypotheses were that (1) dissociated Co and Cr, originated from MoM-wear particles, accumulate in the bone marrow and (2) apparently impair the osteogenic function of local MSCs. This impairment could be one element contributing to the manifestation of periprosthetic osteolyses.

METHODS

The study was approved by the local ethical committee (EA1/194/13); all donors gave written informed consent. Blood (B), Synovial fluid (SF) periprosthetic tissue (PT) and bone marrow (BM) were collected from patients with at least one osteolytic lesion, undergoing a revision of a MoM hip implant. Patients undergoing primary THA served as controls. Metal wear particles were isolated from PT by enzymatic digestion and their size and shape characterized by transmission electron microscopy (TEM). Local and systemic levels of Co and Cr were analyzed by graphite furnace atomic absorption spectroscopy. MoM-MSCs and control-MSCs were isolated from BM for in vitro assessment of their viability, proliferation, migration and multilineage differentiation. In addition, control-MSCs were in vitro exposed to Co and Cr ions and assessed for their viability, proliferation and osteogenic differentiation.


The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1185 - 1188
1 Sep 2016
Hommel H Perka C Kopf S

Aims

It is widely held that most Baker’s cysts resolve after treatment of the intra-articular knee pathology. The present study aimed to evaluate the fate of Baker’s cysts and their associated symptoms after total knee arthroplasty (TKA).

Patients and Methods

In this prospective cohort study, 102 patients with (105 were included, however three were lost to follow-up) an MRI-verified Baker’s cyst, primary osteoarthritis and scheduled for TKA were included. Ultrasound was performed to evaluate the existence and the gross size of the cyst before and at one year after TKA. Additionally, associated symptoms of Baker's cyst were recorded pre- and post-operatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 56 - 56
1 May 2016
Janz V Bartek B Wassillew G Trampuz A Winkler T Perka C
Full Access

Introduction

Despite the lack of data regarding the diagnostic validity of synovial aspiration in Girdlestone hips a Girdlestone-aspiration is often performed before reimplantation to detect a possible persistence of infection during two staged revision total hip arthroplasty (THA). The aim of this study was to assess the diagnostic performance of the synovial aspiration in Girdlestone hips, without a PMMA-Spacer, for the detection of infection persistence prior to THA reimplantation.

Methods

Seventy four patients undergoing a two staged revision THA surgery between 2006 and 2013 were included in this retrospective cohort study. Both synovial cultures and CRP values were acquired before explantation of the THA and of the Girdlestone hip before reimplantation. An antibiotic holiday of 14 days was observed prior to synovial aspiration.

A PJI was defined according to the following criteria: intraarticular presence of pus or a sinus tract, a periprosthetic membrane indicative of infection in the histological analysis, or a positive microbiological isolation in a minimum of two samples.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 57 - 57
1 May 2016
Wassillew G Perka C Janz V Renner L
Full Access

INTRODUCTION

The efficacy of tranexamic acid (TXA) to reduce blood loss in various surgical procedures has been proven. However, there is little data about the effect of TXA on blood loss, rate of blood transfusion and thromboembolic events during periacetabular osteotomy (PAO). The reduction of blood loss during PAO promotes postoperative mobilization and reduces the risk of complications, associated with blood transfusions. The aim of the following study was to determine, if TXA can reduce both blood loss and the rate of blood transfusions. In addition we analyzed whether TXA was associated with an increased risk of thromboembolic events.

METHODS

A consecutive series of 96 PAO procedures was reviewed to compare the groups immediately prior to and following the routine implementation of TXA. The TXA group received a continuous infusion of TXA with a rate of 10mg/kg/h. The outcome was blood transfusion rate, total blood loss, length of hospital stay, and thromboembolic events.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 80 - 80
1 May 2016
Trampuz A Maiolo E Winkler T Perka C
Full Access

Background

The main reasons for hip prosthesis failure are aseptic loosening and periprosthetic joint infection (PJI). The real frequency of PJI is probably largely underestimated because of non-standardized definition criteria, diagnostic procedure, treatment algorithm and other confounders. Therefore, data from joint registries are not reflecting the frequency of PJI and can be misleading; particularly low-grade PJI can be frequently misdiagnosed as aseptic failure. Therefore, prospective clinical studies with standardized protocol, comprehensive diagnostic procedure and sufficient follow-up should be performed. Sonication of explanted prosthesis is highly sensitive for detection of biofilms on prosthetic surface and allows quantitative analysis of biofilm formation. We hypothesize that by using sonication, ceramic components (BIOLOX®delta, BIOLOX®forte) will show higher resistance against biofilm adhesion compared to polyethylene (PE) and metal (CoCrMo).

Methods

In this prospective multicentre study (level of evidence: Ia), we included all consecutive adults ≥18 years of age, who underwent explantation of the hip prosthesis for infection or aseptic reason. Excluded were patients in whom part of the prosthetic components were retained. A standardized and comprehensive diagnostic algorithm was applied, including sonication of all removed prosthetic components for qualitative and quantitative microbiological analysis (ultrasound bath 40 kHz, 1 W/cm2, 1 min). Individual components (metal, PE, ceramic) were separately placed in sterile boxes for investigation. All patients were simultaneously included in the European Prosthetic joint infection cohort (EPJIC, www.epjic.org) to ensure long-term follow-up.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 71 - 71
1 Jan 2016
Janz V Wassilew GI Perka C
Full Access

Introduction

A timely isolation of the causative bacterial species is of paramount importance in the treatment of periprosthetic joint infection (PJI). Sonication of the explanted endoprosthesis and the microbiological culture of sonicate fluid (SFC) has been proven to increase the rate of bacterial isolations in comparison to the conventional microbiological methods. The cultivation of aspired synovial fluid in blood culture bottles (BCB) has been shown to yield a higher rate of bacterial isolations and produce a lower rate of contaminants than cultivation on conventional agar plates. The primary aim of this study was to investigate whether the inoculation of BCB with sonicate fluid leads to a higher rate of bacterial isolations than the culture on agar plates. Secondly, we wanted to investigate whether the utilization of BCB leads to an earlier identification of the causative bacterial species. To our knowledge this is the first study to investigate the effects of BCB use on SFC.

Methods

We performed a retrospective analysis comparing the results of the two different culture methods. To detect slow growing species all microbiological cultures, regardless of the culture method, were incubated for 14 days.


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 14 - 17
1 Jan 2016
Sentuerk U von Roth P Perka C

The leading indication for revision total hip arthroplasty (THA) remains aseptic loosening owing to wear. The younger, more active patients currently undergoing THA present unprecedented demands on the bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest rates of wear. The recent advances, especially involving alumina/zirconia composite ceramic, have led to substantial improvements and good results in vitro.

Alumina/zirconia composite ceramics are extremely hard, scratch resistant and biocompatible. They offer a low co-efficient of friction and superior lubrication and lower rates of wear compared with other bearings. The major disadvantage is the risk of fracture of the ceramic. The new composite ceramic has reduced the risk of fracture of the femoral head to 0.002%. The risk of fracture of the liner is slightly higher (0.02%).

Assuming that the components are introduced without impingement, CoC bearings have major advantages over other bearings. Owing to the superior hardness, they produce less third body wear and are less vulnerable to intra-operative damage.

The improved tribology means that CoC bearings are an excellent choice for young, active patients requiring THA.

Cite this article: Bone Joint J 2016;98-B(1 Suppl A):14–17.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1604 - 1607
1 Dec 2015
Wassilew GI Perka C Janz V Krämer M Renner L

We have investigated the effect of using tranexamic acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative blood loss and blood transfusion requirements. In addition we analysed whether the use of TXA was associated with an increased risk of venous thromboembolism (VTE) following this procedure.

A consecutive series of 96 PAOs, performed by a single surgeon, were reviewed. A total of 48 patients received TXA and 48 did not. The TXA group received a continuous infusion of TXA at a rate of 10 mg/kg/h. The primary outcome measure was the requirement for blood transfusion. Secondary outcomes included total blood loss, the decrease in the level of haemoglobin in the blood, the length of hospital stay, and the complications of this treatment.

The mean rate of transfusion was significantly lower in the TXA group (62.5% vs 12.5%, p < 0.001). The mean blood loss was also significantly reduced in the TXA group (1.9 L (standard deviation (sd) 0.9) vs 1.5 L (sd 0.7), p < 0.01). No post-operative episodes of VTE were identified in either group.

The use of TXA reduced the blood loss and the rate of transfusion after PAO significantly, without adverse effects such as an increased rate of VTE.

Cite this article: Bone Joint J 2015;97-B:1604–7.


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1615 - 1622
1 Dec 2015
Müller M Abdel MP Wassilew GI Duda G Perka C

The accurate reconstruction of hip anatomy and biomechanics is thought to be important in achieveing good clinical outcomes following total hip arthroplasty (THA). To this end some newer hip designs have introduced further modularity into the design of the femoral component such that neck­shaft angle and anteversion, which can be adjusted intra-operatively. The clinical effect of this increased modularity is unknown. We have investigated the changes in these anatomical parameters following conventional THA with a prosthesis of predetermined neck–shaft angle and assessed the effect of changes in the hip anatomy on clinical outcomes.

In total, 44 patients (mean age 65.3 years (standard deviation (sd) 7); 17 male/27 female; mean body mass index 26.9 (kg/m²) (sd 3.1)) underwent a pre- and post-operative three-dimensional CT scanning of the hip. The pre- and post-operative neck–shaft angle, offset, hip centre of rotation, femoral anteversion, and stem alignment were measured. Additionally, a functional assessment and pain score were evaluated before surgery and at one year post-operatively and related to the post-operative anatomical changes.

The mean pre-operative neck–shaft angle was significantly increased by 2.8° from 128° (sd 6.2; 119° to 147°) to 131° (sd 2.1; 127° to 136°) (p = 0.009). The mean pre-operative anteversion was 24.9° (sd 8; 7.9 to 39.1) and reduced to 7.4° (sd 7.3; -11.6° to 25.9°) post-operatively (p < 0.001). The post-operative changes had no influence on function and pain. Using a standard uncemented femoral component, high pre- and post-operative variability of femoral anteversion and neck–shaft angles was found with a significant decrease of the post-operative anteversion and slight increase of the neck–shaft angles, but without any impact on clinical outcome.

Cite this article: Bone Joint J 2015;97-B:1615–22.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 6 - 6
1 Feb 2015
Perka C
Full Access

The leading cause for total hip arthroplasty (THA) revision remains aseptic loosening due to bearing wear. The younger and more active patients currently undergoing arthroplasty present unprecedented demands on THA-bearings. Ceramic-on-ceramic (CoC) bearings have consistently shown the lowest wear rates. The recent advances, especially in alumina CoC bearings, have solved many past problems and produced preferable results in vitro.

Alumina ceramics are extremely hard, scratch resistant, biocompatible, offer a low coefficient of friction, superior lubrication and lower wear rates in comparison to other bearings in THA. The major disadvantage of ceramics used to be fracture. The new generation of alumina ceramics, has reduced the risk of ball fracture to 0.03–0.05%. The risk for liner fracture is even lower.

Assuming an impingement-free component implantation, CoC bearings have major advantages over other bearing combinations. Due to the superior hardness, CoC bearings produce less third body wear and are virtually impervious to damage from instruments during the implantation process.

A complication specific to CoC bearings is squeaking. Squeaking occurs if the friction in the joint articulation is sufficient to excite vibrations to audible magnitudes (due to loss of lubrication). The high range of reported squeaking (0.45% to 10.7%) highlights the importance of correct implant position. If a correct implant position can be guaranteed, then squeaking is rare and without clinical significance.

The improved tribology and presumable resulting implant longevity make CoC the bearing of choice for young and active patients. Especially the alumina matrix (Biolox delta) offers increased burst strength and greater fracture toughness.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 30 - 30
1 Feb 2015
Perka C
Full Access

The endoprosthetic treatment of secondary osteoarthritis resulting from congenital hip dysplasia is difficult due to the small diameter of the acetabulum and the hypoplastic anterolateral bone stock. On the femoral side the increased femoral anteversion, insufficient femoral offset and proximal femoral deformities (mostly valgus deformities) as well as the small diameter and straight form of the intramedullary canal pose challenges. Careful preoperative planning is mandatory. The Crowe classification is usually used to describe these pathologies. In severe cases (Crowe 3 and especially Crowe 4) a shortening and derotating femoral osteotomy should be taken into account. Small acetabular components, acetabular augments, and modular femoral components must be available at all times.

For acetabular fixation press-fit cups are preferred today, but excellent results were also described for threaded cups. The advantage of press-fit cups is the extensively documented and superior track record, but threaded cups allow for an easier reconstruction of the original hip center as well as slight medialization. As a result of medialization a reduction in polyethylene wear together with a low rate of loosening lead to very good long-term results in a younger patient population.

Cementless straight stems are documented to be preferable for the small femoral diameter and the straight anatomic shape of the proximal femur. Nevertheless, the higher complication rate, especially the increased rate of nerve palsies, should be preoperatively discussed with the patient. The ideal bearing surface is currently unclear, ceramic-on-ceramic seems to be promising, although the longest data available support the use of metal-on-polyethylene.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1618 - 1622
1 Dec 2014
von Roth P Abdel MP Wauer F Winkler T Wassilew G Diederichs G Perka C

Intact abductors of the hip play a crucial role in preventing limping and are known to be damaged through the direct lateral approach. The extent of trauma to the abductors after revision total hip replacement (THR) is unknown. The aim of this prospective study was to compare the pre- and post-operative status of the gluteus medius muscle after revision THR. We prospectively compared changes in the muscle and limping in 30 patients who were awaiting aseptic revision THR and 15 patients undergoing primary THR. The direct lateral approach as described by Hardinge was used for all patients. MRI scans of the gluteus medius and functional analyses were recorded pre-operatively and six months post-operatively. The overall mean fatty degeneration of the gluteus medius increased from 35.8% (1.1 to 98.8) pre-operatively to 41% (1.5 to 99.8) after multiple revision THRs (p = 0.03). There was a similar pattern after primary THR, but with considerably less muscle damage (p = 0.001), indicating progressive muscle damage. Despite an increased incidence of a positive Trendelenburg sign following revision surgery (p = 0.03) there was no relationship between the cumulative fatty degeneration in the gluteus medius and a positive Trendelenburg sign (p = 0.26). The changes associated with other surgical approaches to the hip warrant investigation.

Cite this article: Bone Joint J 2014;96-B:1618–22.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 87 - 87
1 Dec 2013
Janz V Wassilew GI Matziolis G Tohtz S Perka C
Full Access

Introduction

The utilization of sonicate fluid cultures (SFC) has been shown to increase the detection rate of periprosthetic joint infection (PJI) in comparison to the use of conventional microbiological methods, because sonication enables a sampling of the causative bacteria directly from the surface of the endoprosthetic components. The hypothesis of this study is that not only will the detection rate of PJI be improved, but also the detection rate of polymicrobial infection in patients with total knee arthroplasty (TKA) revision surgery.

Material and methods

74 patients which underwent TKA revision surgery received a synovial aspiration, intraoperative tissue cultures, histological sampling of the periprosthetic membrane, and sonication of the explanted endoprosthesis. A PJI was defined according to the following criteria: presence of intraarticular pus or a sinus tract, positive isolation of causative bacteria in ≥2 microbiological samples or a histological membrane indicative of infection (type II or III periprosthetic membrane).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 199 - 199
1 Dec 2013
Wassilew GI Heller M Perka C
Full Access

INTRODUCTION:

Acetabular retroversion has been implicated as a risk factor for the development of early hip osteoarthritis. In clinical practice standard osseous signs such as the cross-over sign (COS) and the posterior wall sign (PWS) are widely used to establish the diagnosis of acetabular retroversion on plain radiographs. Despite standardized radiological evaluation protocols, an increased pelvic tilt can lead to a misdiagnosis of acetabular retroversion in AP radiographs and 2D MR or CT scans. Previous studies have shown that the elimination of observer bias using a standardized methodology based on 3D-CT models and the anterior pelvic plane (APP) for the assessment of COS and PWS results in greater diagnostic accuracy. Using this method a prevalence of 28% for COS and 24% for PWS has been found in a cohort of patients with symptoms indicative of FAI, however the prevalence of both signs in asymptomatic adults remains unknown. This study therefore sought to establish the prevalence of the COS and PWS in relation to the APP in an asymptomatic population using a reliable and accurate 3 D-CT based assessment.

METHODS:

A large pool of consecutive CT scans of the pelvis undertaken in our department for conditions unrelated to disorders of the hip was available for analysis. Scans in subjects with a Harris hip score of less than 90 points were excluded leaving a sample of 100 asymptomatic subjects (200 hips) for this study. A previously established 3D analysis method designed to eliminate errors resulting from variations in the position and orientation of the pelvis during CT imaging was applied to determine in order to assess the prevalence of the COS and PWS in relation to the APP. Here, the acetabuli were defined as retroverted if either the COS, PWS or both were positive.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 88 - 88
1 Dec 2013
Janz V Wassilew GI Tohtz S Perka C
Full Access

Introduction

Sonicate fluid cultures (SFC) are more sensitive than conventional microbiological methods in identifying periprosthetic joint infections (PJI), because sonication enables a sampling of the causative bacteria directly from the surface of the endoprosthetic components. Because of their high sensitivity SFC can be positive while all other microbiological methods remain negative. It is therefore difficult to interpret a single SFC as being truly or falsely positive. The aim of this prospective study was to improve the interpretation of SFC in the diagnosis of PJI in patients after total hip arthroplasty through the use of multiple SFC.

Material and methods

102 patients of which 37 had a defined PJI according to the following criteria were included: intraarticular pus or a sinus tract, a periprosthetic membrane (PM) indicative of infection, or a positive microbiological culture in a minimum of 2 separate microbiological samples. A single positive microbiological sample was classified as false positive. In 35 patients multiple SFC were acquired from the separate endoprosthetic components.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 115 - 115
1 Sep 2012
Morlock M Bishop N Perka C
Full Access

Head sizes used in total hip arthroplasty (THA) has increased drastically from the original 22mm used by Charnley. This is due to two factors: the use of hard-on-hard materials for the bearing articulation and the increasing problem of dislocation.

The tribological aspect

Hard-on-hard materials enable mixed or fluid film lubrication due to their good wettability. The development of a fluid film layer is encouraged by smaller surface pressures (larger area) and higher velocity at the articulating interface (larger radius), suggesting that larger diameters exhibit better lubrication and such less wear. This was effectivly proven in pre-clinical simulator studies and used as argument to increase the diameters of metal-on-metall and ceramic-on-ceramic bearings. Clinically the tribological advantage of larger diameters has not yet been shown. For hard-on-soft bearings the situation is different. Due to the bad wettability of Polyethylene (PE), the abrasive wear regime is dominant. This means that the longer wear path of a larger diameter will inevitably carry a larger amount of wear debris. Despite this relation, the heads used in combination with PE were also increased up to 40mm diameter, justified by the overall greatly reduced wear amount of the new generation(s) of cross-linked PE and favourable simulator results. First in-vivo studies have shown that larger heads carry larger amounts of wear particles. Whether this increase is relevant with respect to osteolysis is still unclear and will have to be shown in longer term studies.

The biomechanical aspect

Larger heads require a larger “jumping” distance until they dislocate. Consequently the use of larger heads reduces dislocation rates, which was shown in multiple clinical studies. However, the reduction in dislocation rate achieved by increasing diameters varies greatly. Some centres achieve dislocation rates below 1% with 28mm heads, other centres require 36mm heads to achieve the same result. No study shows any further advantage with head diameters larger than 36mm. Despite their obvious biomechanical advantage with regard to stability, larger heads also have large disadvantages. Larger heads carry inevitably larger friction moments, requiring better anchoring of the components. In unfavourable conditions (start-up, break-down of lubrication film), friction moments of hard-on-hard bearings can get very high and reach or even exceed the losening torque of the head on the taper. Depending on the head impaction foce during assembly, the loosening torques amount to 8 to 17Nm. Movement at the head-taper connection possibly causes wear and increased corrosion at this interface. Larger head diameters also require thinner shells and/or liners, leading to problems with liner chipping or incomplete seating. Large head diameters have also lead to the use of sub-hemispherical cups with reduced covering surface, increasing the risk of fluid film break down due to edge loading if not well positioned. Finally, larger heads might give the surgeon a wrong feeling of security regarding a sub-optimal positioned cup.

The question regarding “the optimal” head diameter is open for discussion and needs to consider the bearing material used. Head size should be limited to a reasonable compromise, which based on the information currently available, could be 36mm. Join the “36 and under” club.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 470 - 471
1 Nov 2011
Dynybil C Snel J Kääb M Perka C
Full Access

Purpose: The objective of the present study was to evaluate whether horizontal cleavage and complex meniscus tears, which supposed to be degenerative tears, are associated with an increase of specific matrix metalloproteinases and an increased incidence of cartilage damage, in comparison with patients having other patterns of meniscal injury1,2.

Materials and Methods: Data were collected prospectively from 32 knee arthroscopies, patients were assigned by intraoperative findings due to their meniscal tear to one of two groups: “degenerative meniscal lesions” (horizontal cleavage and complex tears; n=20) or “traumatic tears” (longitudinal and radial tears; n=12). Patient data (age, duration of symptoms, mechanism of injury, body mass index [BMI]), intra-articular and radiographic findings were recorded. Samples of knee joint fluid were analyzed for the matrix matrix metalloproteinases pro-MMP-1, MMP-3 and pro-MMP-13, which are postulated to be involved in articular cartilage degradation3. Cartilage changes were classified intraoperative by Outerbridge (grade 0–4). Praeoperative bone morphology of the knee joint was graduated by Kellgren-Lawrence (Stadium 0–4). The Knee Injury and Osteoarthritis Outcome Score (KOOS) was used to assess the patients opinion about their knee and associated symptoms and function preoperative and 1.5 years postoperative.

Results: Degenerative meniscus lesions appeared predominantly at the end of fifty years of age (58.5±13.9 years), whereas other patterns of meniscal lesions happened around 30 years of age (28.7±8.1 years; P< .0001; Fig. 1 [Median]). Patients with a degenerative meniscus lesion had marginally overweight, whereas patients with a traumatic tear were in the normal range regarding the body mass index (BMI 23.7±5.3 vs. BMI 26.8±3.9; P=.044). A comparison of patients with horizontal cleavage and complex meniscal tears (“degenerative tears”) to patients with longitudinal or radial (“traumatic”) tears showed for the former increased severity of chondral lesions (Outerbridge: 2.9±1.4 vs 1.1±0.9; P=.001; Fig. 2 [Median]) and radiographic osteoarthritis (Kellgren-Lawrence: 1.9±1.5 vs 0.4±0.5; P=.004; Fig. 3 [Median]). The KOOS improved after arthroscopic treatment in the degenerativemeniscal-tear group as well as in the traumatic-tear group significantly (Total-KOOS Score preoperative: 36.5±30.7 and 38.1±24.8; Total-KOOS Score 1.5 years postoperative: 87.8±6.7 and 49.2±21.9; p=.043 and p=.012; “0” indicates extreme knee problems; “100” indicates no knee problems; Fig. 4 [Median]). Pro-MMP-13 correlated significantly with an increase of chondral lesions and radiographic osteoarthritis (r=.534; p=.003; r=.457; p=.02). MMP-3 concentrations in the synovial fluid of patients with a degenerative meniscus lesion were about 20% higher compared to patients with other patterns of meniscal lesions. No one of the investigated MMPs correlated significantly with a specific meniscal injury (Fig. 5 [Median]).

Conclusions: Complex and horizontal cleavage meniscal tears are not as benign as was previously thought and are highly associated with an increased severity of cartilage degeneration and radiographic osteoarthritis. In spite of distinct cartilage changes arthroscopic treatment improved knee-related symptoms at least on medium-term also in patients with degenerative meniscal tears. In this study, increased concentrations of the investigated MMPs did not seem to be associated with specific patterns of meniscal lesions.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 134 - 134
1 May 2011
Von Roth P Radojewski P Matziolis G Duda G Perka C Winkler T
Full Access

Objectives: Skeletal muscle trauma leads to severe functional deficits. Present therapeutic treatments are unsatisfying and insufficient posttraumatic regeneration is a problem in trauma and orthopaedic surgery. Mesenchymal stem cell (MSC) therapy is a promising tool in the regeneration of muscle function after severe trauma. Our group showed increased contraction forces compared to a non-treated control group 3 weeks after MSC transplantation (TX) into a skeletal muscle trauma. In addition we demonstrated a dose-response relationship of the amount of MSC and force enhancement. We furthermore investigated the fate of the transplanted MSC labelled with very small iron oxide particles using 7 Tesla-MRI. Histological analysis revealed fusion events between existing myofibers but only to a low amount. The increase of muscle force can not be explained by these events only. Before further steps are taken the impact of paracrine effects and the homing to the site of trauma of the MSC has to be evaluated. Experimental studies about the functional regeneration of traumatized skeletal muscule after systemic MSC-TX do not exist.

Methods: 36 female SD-rats received open crush trauma of the left soleus muscle. One week after trauma 2.5 x 106 autologous MSC, harvested from tibial biopsies, were transplanted intraarterially (i.a., femoral arte-ria, group 1) or intravenously (i.v., tail vein, group 2) (n=18). Control animals received saline (i.a.: group 3; i.v.: group 4) (n=18). Histological analysis and biomechanical evaluation by in vivo muscle force measurement was performed 3 weeks after TX.

Results: Twitch stimulation of the healthy right soleus muscles resulted in a contraction force of 0.52±0.14 N. Forces of tetanic contraction in the uninjured muscles reached 0.98±0.27 N. The i.a. MSC-TX improved the muscle force of the injured soleus significantly compared to control (twitch: 82,4%, p=0.02, tetany: 61.6%, p=0.02). Contraction forces of muscles treated i.v. (MSC vs. saline) showed no significant difference. The histological analysis showed no differences in the amount of fibrotic tissue.

Conclusions: The presented study demonstrates the effect of systemic MSC-TX in the treatment of severe skeletal muscle injuries. Interestingly, the functional regeneration could only be increased by i.a. application. The entrapment of MSC in the lungs and the dilution effect in the circulation, when injecting the MSC i.v. could be the reason. For possible future therapeutic approaches a systemic application is considered to be favourable compared to local injections due to the better distribution of the cells in the target muscle.