header advert
Results 1 - 20 of 73
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_10 | Pages 6 - 6
1 Aug 2021
Kennedy I Hrycaiczuk A Ng N Sheerins O Patil S Jones B Stark A Meek D
Full Access

Periprosthetic fractures (PPF) of the femur following total hip arthroplasty represent a significant complication with a rising incidence. The commonest subtype is Vancouver B2 type, for which revision to a long uncemented tapered fluted stem is a widely accepted management. In this study we compare this procedure to the less commonly performed cement-in-cement revision.

All patients undergoing surgical intervention for a Vancouver B2 femoral PPF in a cemented stem from 2008 – 2018 were identified. We collated patient age, gender, ASA score, BMI, operative time, blood transfusion requirement, change in haemoglobin (Hb) level, length of hospital stay and last Oxford Hip Score (OHS). Radiographic analysis was performed to assess time to fracture union and leg length discrepancy. Complications and survivorship of implant and patients were recorded.

43 uncemented and 29 cement-in-cement revisions were identified. There was no difference in patient demographics between groups. A significantly shorter operative time was found in the cement-in-cement group, but there was no difference in transfusion requirement, Hb change, or length of hospital stay. OHS was comparable between groups. A non-significant increase in overall complication rates was found in the revision uncemented group, with a significantly higher dislocation rate. Time of union was comparable and there were no non-unions in the cement-in-cement group. A greater degree of stem subsidence was found in the uncemented group. There was no difference in any revision surgery required in either group. Three patients in the uncemented group died in the perioperative period, compared to none in the cement-in-cement group.

With appropriate patient selection, both cement-in-cement and long uncemented tapered stem revision represent appropriate treatment options for Vancouver B2 fractures.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 272 - 278
1 Jun 2020
Tapasvi S Shekhar A Patil S Pandit H

Aims

The mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position.

Methods

A total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position.


Bone & Joint Research
Vol. 7, Issue 1 | Pages 103 - 104
1 Jan 2018
Young PS Patil S Meek RMD


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 445 - 450
1 Apr 2017
Marsh AG Nisar A El Refai M Patil S Meek RMD

Aims

The purpose of this study was to evaluate whether an innovative templating technique could predict the need for acetabular augmentation during primary total hip arthroplasty for patients with dysplastic hips.

Patients and Methods

We developed a simple templating technique to estimate acetabular component coverage at total hip arthroplasty, the True Cup: False Cup (TC:FC) ratio. We reviewed all patients with dysplastic hips who underwent primary total hip arthroplasty between 2005 and 2012. Traditional radiological methods of assessing the degree of acetabular dysplasia (Sharp’s angle, Tönnis angle, centre-edge angle) as well as the TC:FC ratio were measured from the pre-operative radiographs. A comparison of augmented and non-augmented hips was undertaken to determine any difference in pre-operative radiological indices between the two cohorts. The intra- and inter-observer reliability for all radiological indices used in the study were also calculated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 114 - 114
1 May 2016
D'Lima D Colwell C Hsu A Bunn A Patil S
Full Access

Background

Despite the success of total knee arthroplasty (TKA) restoration of normal function is often not achieved. Soft-tissue balance is a major factor leading to poor outcomes including malalignment, instability, excessive wear, and subluxation. Mechanical ligament balancers only measure the joint space in full extension and at 90° flexion. This study uses a novel electronic ligament balancer to measure the ligament balance in normal knees and in knees after TKA to determine the impact on passive and active kinematics.

Methods

Fresh-frozen cadaver legs (N = 6) were obtained. A standard cruciate-retaining TKA was performed using measured resection approach and computer navigation (Stryker Navigation, Kalamazoo, MI).

Ligament balance was measured using a novel electronic balancer (Fig 1, XO1, XpandOrtho, Inc, La Jolla, CA, USA). The XO1 balancer generates controlled femorotibial distraction of up to 120N. The balancer only requires a tibial cut and can be used before or after femoral cuts, or after trial implants have been mounted. The balancer monitors the distraction gap and the medial and lateral gaps in real time, and graphically displays gap measurements over the entire range of knee flexion. Gap measurements can be monitored during soft-tissue releases without removing the balancer.

Knee kinematics were measured during active knee extension (Oxford knee rig) and during passive knee extension under varus and valgus external moment of 10Nm in a passive test rig.

Sequence of testing and measurement:

Ligament balance was recorded with the XO1 balancer after the tibial cut, after measured resection of the femur, and after soft-tissue release and/or bone resection to balance flexion-extension and mediolateral gaps.

Passive and active kinematics were measured in the normal knee before TKA, after measured resection TKA, and after soft-tissue release and/or bone resection to balance flexion-extension and mediolateral gaps.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 72 - 72
1 Jan 2016
Nagamine R Weijia C Patil S D'Lima D Todo M
Full Access

Introduction

The effect of each step of medial soft tissue release was assessed taking the expansion strength and patellar condition into account in five fresh frozen normal cadaver specimens.

Methods

In each cadaver specimen, only proximal tibia was cut. Then, ACL was cut, and deep MCL fiber was released. This condition was set as “the basic”. Joint gap distance and angle were measured at full extension, 30°, 60°, 90°, 120° flexion and in full flexion. The measurement was firstly done with the standard tensor/balancer with the patella everted, and the next with the offset tensor/balancer with the patella reduced. The torque of 10, 20 and 30 inch-pounds were applied through the specialized torque wrench. After the measurement in “the basic”, PCL, MCL superficial fibres, pes anserinus and semi-membranosus were released step by step. Measuring the joint gap distance and angle with the same scheme above were conducted after the each step.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 103 - 103
1 Jan 2016
D'Lima D Patil S Bunn A Colwell C
Full Access

Background

Despite the success of total knee arthroplasty (TKA) restoration of normal function is often not achieved. Soft tissue balance is a major factor for poor outcomes including malalignment, instability, excessive wear, and subluxation. Computer navigation and robotic-assisted systems have increased the accuracy of prosthetic component placement. On the other hand, soft tissue balancing remains an art, relying on a qualitative feel for the balance of the knee, and is developed over years of practice

Several instruments are available to assist surgeons in estimating soft tissue balance. However, mechanical devices only measure the joint space in full extension and at 90° flexion. Further, because of lack of comprehensive characterization of the ligament balance of healthy knees, surgeons do not have quantitative guidelines relating the stability of an implanted to that of the normal knee. This study measures the ligament balance of normal knees and tests the accuracy of two mechanical distraction instruments and an electronic distraction instrument.

Methods

Cadaver specimens were mounted on a custom knee rig and on the AMTI VIVO which replicated passive kinematics. A six-axis load cell and an infrared tracking system was used to document the kinematics and the forces acting on the knee.

Dynamic knee laxity was measured under 10Nm of varus/valgus moment, 10Nm of axial rotational moment, and 200N of AP shear. Measurements were repeated after transecting the anterior cruciate ligament, after TKA, and after transecting the posterior cruciate ligament.

The accuracy and reproducibility of two mechanical and one electronic distraction device was measured.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 52 - 52
1 Nov 2015
Marsh A Kennedy I Nisar A Patil S Meek R
Full Access

Introduction

Cement in cement revision with preservation of the original cement mantle has become an attractive and commonly practised technique in revision hip surgery. Since introducing this technique to our unit we have used two types of polished tapered stem. We report the clinical and radiological outcomes for cement in cement femoral revisions performed using these prostheses.

Materials and Methods

All patients who underwent femoral cement in cement revision with a smooth tapered stem between 2005 –2013 were assessed. Data collected included indication for revision surgery and components used. All patients were followed up annually. Outcomes recorded were radiographic analysis, clinical outcome scores (Oxford Hip Score, WOMAC and SF-12) and complications, including requirement for further revision surgery. Median follow-up was 5 years (range 1 – 8 years).

116 revision procedures utilising cement in cement femoral revision were performed in the 8 year study period (68 females, 48 males, and mean age of 69 years). The femoral component was a C-stem AMT (Depuy) in 59 cases and Exeter stem (Stryker) in 57 cases.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 5 - 5
1 Apr 2015
Al Fakayh O Marsh A Patil S
Full Access

Ganz peri-acetabular osteotomy is commonly used to treat symptomatic hip dysplasia. It aims to increase the load bearing contact area of the hip to reduce the risk of subsequent osteoarthritis. In this study we assess the radiographic and clinical results of the procedure since its introduction to our unit.

All patients undergoing Ganz osteotomies at our unit were followed up prospectively. Data collected included patient demographics and pre- and post-operative functional scores (Harris and Non-arthritic hip scores). In addition, acetabular correction was evaluated on pre-and post-operative radiographs (using Centre-Edge angle and Tonnis angle). Complications were also noted.

Overall 50 procedures were performed between 2007 and 2013 with median follow-up of 3 years (1 – 7 years). The majority of patients (90%) were female. Average age at time of surgery was 29 years (16–49). There were significant improvements in pre- and post-operative median functional scores (Modified Harris Hip Score = 49 versus 64, p=0.001), Non-arthritic Hip Score = 42 versus 56, p=0.007). Median Centre Edge Angle improved from 16 degrees pre-operatively (range = 7–31 degrees) to 30 degrees post-operatively (18–33) degrees), p<0.0001. Similarly, pre-operative Tonnis angle improved from 18 degrees (9–38) to 7 degrees (2–14), p<0.0001. Five patients developed post-operative complications: 2 superficial wound infection, 1deep infection requiring hip washout and antibiotic treatment and 2 patients subsequently requiring total hip replacements.

We have shown that the Ganz peri-acetabular osteotomy can be effective for the treatment of painful hip dysplasia improving both functional and radiographic outcomes. However, patient selection is a key factor.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 14 - 14
1 Apr 2015
Halai M Augustine A Holloway N MacDonald D Mohammed A Meek R Patil S
Full Access

Two major challenges in arthroplasty are obesity and antibiotic resistance. This study was performed to characterise the organisms responsible for deep infection following total hip arthroplasty and to determine if obesity affected the microbiology profile.

A retrospective analysis of the national surgical site infection register was made to obtain data regarding deep infection following 10948 primary total hip arthroplasty (THA) from 1998–2013, with a minimum of 2 year follow-up.

Of all the primary THAs performed, there were 108 deep infections (56 patients had a BMI >30 (obese) and 52 patients <30). There were no significant differences between cardio-respiratory disease, smoking and alcohol status, and diabetes between the 2 groups. Over the last 15 years, staphylococcus aureus continues to be the most frequently isolated organism. Infection with multiple organisms was found exclusively in obese patients. Furthermore, in obese patients, there was a linear increase with methicillin resistant staphylococcus aureus (MRSA) infections and streptococcus viridans.

On this basis, we recommend careful selection of antibiotic therapy in obese patients, rather than empirical therapy, which can be especially important if there is no growth in an infected THA. In addition, a preoperative discussion regarding dental prophylaxis against streptococcus viridans may be warranted.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_3 | Pages 12 - 12
1 Apr 2015
Bradman H Patil S Martin D Marsh A
Full Access

Postgraduate training in orthopaedics has traditionally been delivered through an apprenticeship model. However, junior doctor working patterns have more recently moved away from a team based structure, potentially affecting training experience. We aimed to compare the perceived quality of training between medical students, junior non-orthopaedic trainees and orthopaedic specialty trainees.

We conducted an anonymous questionnaire of all medical students and trainees rotating through our unit over 24 months. The questionnaire contained 6, 10-point Likert rating scale questions and free text responses. Results were collated and analysed according to training stage.

Of 82 questionnaires distributed, 60 (73%) were completed (18 specialty registrars, 22 junior trainees and 20 medical students). Junior trainees consisted of 8 GPSTs and 14 Foundation Year (FY2) doctors, only one of whom had specifically chosen an orthopaedic placement.

Median Likert rating of training experience was (1 = very poor, 10 = excellent): ST4-ST8 = 8 (range 7–9), ST1-ST3 = 7 (6–9), GPSTs/FY2s = 4 (2–5) and medical students = 8 (7–10). Further analysis of junior non-orthopaedic doctors' training experience showed that placement induction, organisation of formal teaching and opportunities for training out with formal sessions were rated as poor. However, content of delivered teaching was rated highly. Free text responses identified several barriers to training including being too busy on wards and no opportunity for protected teaching.

Our study shows that junior non-orthopaedic trainees feel their training experience during orthopaedic placements is much poorer than orthopaedic trainees and medical students. Time constraints and less team based working patterns may detract from their teaching opportunities. In addition, junior doctors rotating through orthopaedic units now have a wider spectrum of career interests with heterogeneous training needs. Therefore, orthopaedic departments may need to adopt a more targeted training programme that recognises individual training needs if junior doctor training is to improve.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_14 | Pages 11 - 11
1 Oct 2014
Marsh A Al Fakayh O Patil S
Full Access

Ganz peri-acetabular osteotomy is commonly used to treat symptomatic hip dysplasia. It aims to increase the load bearing contact area of the hip to reduce the risk of subsequent osteoarthritis. In this study we assess the radiographic and clinical results of the procedure since its introduction to our unit.

All patients undergoing Ganz osteotomies at our unit were followed up prospectively. Data collected included patient demographics and pre- and post-operative functional scores (Harris and Non-arthritic hip scores). In addition, acetabular correction was evaluated on pre-and post-operative radiographs (using Centre-Edge angle and Tonnis angle). Complications were also noted.

Overall 50 procedures were performed between 2007 and 2013 with median follow-up of 3 years (1–7 years). The majority of patients (90%) were female. Average age at time of surgery was 32 years (17–39). There were significant improvements in pre- and post-operative median functional scores (Modified Harris Hip Score = 52 versus 63, p=0.001), Non-arthritic Hip Score = 49 versus 60, p=0.01). Median Centre Edge Angle improved from 15 degrees pre-operatively (range = 8–19 degrees) to 29 degrees post-operatively (22–36 degrees), p=0.02. Similarly, pre-operative Tonnis angle improved from 19 degrees (16–38) to 7 degrees (2–14), p=0.01. Four patients developed post-operative complications: 1 superficial wound infection, 1deep infection requiring hip washout and antibiotic treatment and 2 patients subsequently requiring total hip replacements.

We have shown that the Ganz peri-acetabular osteotomy can be effective for the treatment of painful hip dysplasia improving both functional and radiographic outcomes. However, patient selection is a key factor.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 9 - 9
1 Apr 2014
Marsh A Nisar A El Refai M Meek R Patil S
Full Access

When performing total hip replacements in patients with hip dysplasia, acetabular augmentation may be required to prevent early component failure. Preoperative radiographic templating may help estimate acetabularcomponent coverage but has not previously been shown to predict the need for augmentation.

We developed a simple method to estimate the percentage of acetabular component coverage from pre-operative radiographs (True: False cup ratio). We aimed to evaluate whether this couldpredict the need foracetabular augmentation at primary total hip replacement for patients with dysplastic hips.

We reviewed all patients with hip dysplasia who underwent a primary total hip replacement from 2005–2012. Classification of hip dysplasia (Crowe), centre edge angle (CEA), Sharp and Tonnis angles were determined on pre-operative radiographs for each patient. Templating was performed on anteroposteriorand lateral view hip radiographs to determine the likely percentage of acetabular component coverage using the True: False cup ratio. Patients requiring acetabular augmentation at time of primary total hip arthroplasty were noted.

128 cases were reviewed, 31 (24%) required acetabularaugmentation. Comparison between augmented and non-augmented cases revealed no difference in the mean CEA (p = 0.19), Sharp angles (p = 0.76) or Tonnis angles (p = 0.32). A lower True Cup: False Cup ratio was observed in the augmented groupcompared to the non-augmented group(median = 0.68 vs 0.88, p < 0.01).

Preoperative templating can help predict which dysplastic hips are likely to require acetabular augmentation at primary total hip replacement.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_7 | Pages 16 - 16
1 Apr 2014
Abdelhalim M Gillespie J Patil S
Full Access

Femoroacetabular impingement (FAI) is the result of abnormal contact/impingement of the femoral head-neck junction and acetabulum during motion. This can be corrected by surgical dislocation (using Ganz's trochanteric osteotomy) and femoral osteochondroplasty +/− acetabular rim resection. Our study aimed to assess the improvement in hip scores following open osteochondroplasty to predict outcomes based on patient characteristics.

This was a retrospective case note analysis of a single surgeon case series over a 4 year period. Inclusion criteria were open osteochondroplasty, complete pre- and post-op hip scores available), Tonnis osteoarthritis grade 0 or 1, with 1 year followup. Data was extracted from electronic and paper case notes for pre- and post-op Modified Harris Hip Scores (MHHS), Non-arthritis Hip Scores (NAHS) and SF-12 general satisfaction scores, as well as baseline patient demographics. Two independent observers used the PACS radiology system to examine x-rays and MRI. SPSS version 19 was used for statistical analysis.

42 patients met the inclusion criteria. There was an overall improvement in hip scores after the procedure. Mean pre-op scores were MHHS 52.5, NAHS 44.0, SF-12 32.1. Mean post-op scores were MHHS 66.1, NAHS 58.7, SF-12 36.4. Therefore mean improvements were seen in MHHS (13.6), NAHS (14.7) and SF-12 (4.3), all significant at p<0.005 when paired t-test was used for analysis. Pearson correlation for subgroup analysis showed no significant correlation of scores with age, centre-edge angle or alpha angles. Furthermore, no significant difference was seen between males and females (independent t test).

Open osteochondroplasty improves symptoms and function based on patient reported outcome measures. Although the mean scores improved, some patients’ scores deteriorated. We have not identified any statistically significant predictors of outcome, and therefore patient selection remains unclear.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 40 - 40
1 Dec 2013
D'Lima D Bunn A Patil S Colwell C
Full Access

Introduction:

Kinematic studies are used to evaluate function and efficacy of various implant designs. Given the large variation between subjects, matched pairs are ideal when comparing competing designs. It is logical to deduce that both limbs in a subject will behave identically during a given motion [1], barring unilateral underlying pathology, thus allowing for the most direct comparison of two designs. It is our goal to determine if this is a valid assumption by assessing whether or not there are significant differences present in the kinematics of left and right knees from the same subject. Gait studies have compared pre-and postoperative implantation kinematics for various pathologies like ACL rupture [2] and osteoarthritis [3, 4]. We designed a study to assess squatting in cadaver specimens.

Methods:

Sixteen matched pairs of fresh-frozen cadavers, (Eleven males, five females; aged 71 years [± 10 yrs]) were tested. Each knee, intact, was tested by mounting it on a dynamic, quadriceps-driven, closed-kinetic-chain Oxford knee rig (OKR), which simulated a deep knee bend from full extension to 120° flexion. We chose femoral rollback, tibiofemoral external rotation, tibial adduction, patellofemoral tilt and shift as our outcomes, which were recorded using an active infrared tracking system.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 502 - 502
1 Dec 2013
Robinson J Patil S Rathod P Rodriguez J
Full Access

Introduction:

Subsidence of cementless femoral stems in total hip arthroplasty (THA) has been associated with poor initial fixation and subsequent risk of aspectic loosening. There is limited literature on how subsidence of cementless, proximally porous coated, tapered wedge femoral stems impacts the patient clinically. The aim of our study was to assess whether subsidence with these stems is associated with a decline in clinical function.

Method:

A review of a prospectively collected database of THAs performed by a single surgeon at one institution using two cementless, tapered wedge stem designs from January 2006 to June 2010 was performed. Radiographic analysis using Picture Archiving and Communications System (PACS) was used to identify patients with greater than 1.5 mm of subsidence, and to document osseointegration. Preoperative and postoperative pain and Harris hip scores were recorded; and analyzed to identify if the clinical recovery pattern of the subsidence versus no subsidence groups differed. Protected weight bearing was recommended to all patients with subsidence.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 41 - 41
1 Dec 2013
D'Lima D Patil S Bunn A Bugbee W Colwell C
Full Access

Introduction:

Despite over 95% long-term survivorship of TKA, 14–39% of patients express dissatisfaction due to anterior knee pain, mid-flexion instability, reduction in range of flexion, and incomplete return of function. Changing demographics with higher expectations are leading to renewed interest in patient-specific designs with the goal of restoring of normal kinematics.

Improved imaging and image-processing technology coupled with rapid prototyping allow manufacturing of patient-specific cutting guides with individualized femoral and tibial components with articulating surfaces that maximize bony coverage and more closely approximate the natural anatomy. We hypothesized that restoring the articular surface and maintaining medial and lateral condylar offset of the implanted knee to that of the joint before implantation would restore normal knee kinematics. To test this hypothesis we recorded kinematics of patient-specific prostheses implanted using patient-specific cutting guides.

Methods:

Preoperative CT scans were obtained from nine matched pairs of human cadaveric knees. One of each pair was randomly assigned to one of two groups: one group implanted with a standard off-the-shelf posterior cruciate-retaining design using standard cutting guides based on intramedullary alignment; the contralateral knee implanted with patient-specific implants using patient-specific cutting guides, both manufactured from the preoperative CT scans. Each knee was tested preoperatively as an intact, normal knee, by mounting the knee on a dynamic, quadriceps-driven, closed-kinetic-chain Oxford knee rig (OKR), simulating a deep knee bend from 0° to 120° flexion. Following implantation with either the standard or patient-specific implant, knees were mounted on the OKR and retested. Femoral rollback, tibiofemoral rotation, tibial adduction, patellofemoral tilt and shift were recorded using an active infrared tracking system.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 4 - 4
1 Aug 2013
Marsh A Nisar A Patil S Meek R
Full Access

Repeat revision hip replacements can lead to severe bone loss necessitating salvage procedures such as proximal or total femoral replacement. We present medium term outcomes from our experience of the Limb Preservation System (LPS) in patients with failed revision hip arthroplasties.

All patients undergoing proximal femoral or total femoral replacement from 2003–2007 at our unit were reviewed. Data was collected preoperatively and at annual assessment post procedure for a minimum of 5 years. This included clinical review, functional outcome scores (WOMAC, Oxford Hip Score, Harris Hip Score) and radiographic evaluation.

A total of 17 patients underwent femoral replacement (13 proximal, 4 total) using the LPS during the study period. Within this cohort there were 13 males and 4 females with a mean age of 64 years (range 47–86). Median follow up was 7 years (range 5–9 years). Primary diagnoses were DDH (7), Primary OA (5), RA (2), proximal femoral fracture (2) and phocomelia (1). Five patients (29%) required further revision surgery for infection (2 patients) or recurrent dislocations (3 patients). No stems required revision due to aseptic loosening or stem failure at 5–9 years. Compared to preoperative assessment, there was significant improvement in median outcome scores at 5 years (WOMAC increased by 33 points, Oxford hip score by16 points and Harris hip score by 43 points). 82% of patients maintained functional independence at latest review.

The Limb Preservation System offers a salvage procedure for failed revision total hip arthroplasty with significant symptom and functional improvement in most patients at medium term follow up.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 20 - 20
1 Aug 2013
Elias-Jones C Reilly J Kerr S Meek R Patil S Kelly M Campton L McInnes I Millar N
Full Access

Femoroacetabular impingement (FAI) is a significant cause of osteoarthritis in young active individuals but the pathophysiology remains unclear. Increasing mechanistic studies point toward an inflammatory component in OA. This study aimed to characterise inflammatory cell subtypes in FAI by exploring the phenotype and quantification of inflammatory cells in FAI versus OA samples.

Ten samples of labrum were obtained from patients with FAI (confirmed pathology) during open osteochondroplasty or hip arthroscopy. Control samples of labrum were collected from five patients with osteoarthritis undergoing total hip arthroplasty. Labral biopsies were evaluated immunohistochemically by quantifying the presence of macrophages (CD68 and CD202), T cells (CD3), mast cells (mast cell tryptase) and vascular endothelium (CD34).

Labral biopsies obtained from patients with FAI exhibited significantly greater macrophage, mast cell and vascular endothelium expression compared to control samples. The most significant difference was noted in macrophage expression (p<0.01). Further sub typing of macrophages in FAI using CD202 tissue marker revealed and M2 phenotype suggesting that these cells are involved in a regenerate versus a degenerate process. There was a modest but significant correlation between mast cells and CD34 expression (r=0.4, p<0.05) in FAI samples.

We provide evidence for an inflammatory cell infiltrate in femoroacetabular impingement. In particular, we demonstrate significant infiltration of mast cells and macrophages suggesting a role for innate immune pathways in the events that mediate hip impingement. Further mechanistic studies to evaluate the net contribution and hence therapeutic utility of these cellular lineages and their downstream processes may reveal novel therapeutic approaches to the management of early hip impingement.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 7 - 7
1 May 2013
Patil S Goudie S Keating JF Patton S
Full Access

Vancouver B fractures around a cemented polished tapered stem (CTPS) are often treated with revision arthroplasty. Results of osteosynthesis in these fractures are poor as per current literature. However, the available literature does not distinguish between fractures around CTPS from those around other stems.

The aim of our study was to assess the clinical and radiological outcome of open reduction and internal fixation in Vancouver B fractures around CTPS using a broad non-locking plate.

Patients treated with osteosynthesis between January 1997 and July 2011 were retrospectively reviewed. All underwent direct reduction and stabilisation using cerclage wires before definitive fixation with a broad DCP. Bicortical screw fixation was obtained in the proximal and distal fragments. We defined failure of treatment as revision for any cause.

101 patients (42 men and 59 women, mean age 79) were included. 70 had minimum follow-up of 6 months. 63 of these went on to clinical and radiological union. Three developed infected non-union. 7 had failure of fixation. Lack of anatomical reduction was the commonest predictor of failure followed by inadequate proximal fragment fixation and infection. 14 patients dropped at least 1 mobility grade from their preoperative status.

This is the largest series of a very specific group of periprosthetic fractures treated with osteosynthesis. Patients who develop these fractures are often frail and “high risk” for major revision surgery. We recommend osteosynthesis for patients with Vancouver B periprosthetic fractures around CTPS provided these fractures can be anatomically reduced and adequately fixed.