header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 143 - 143
11 Apr 2023
Lineham B Pandit H Foster P
Full Access

Management of ankle arthritis in young patients is challenging. Although ankle arthrodesis gives consistent pain relief, it leads to loss of function and adjacent joint arthritis. Ankle joint distraction (AJD) has been shown to give good outcomes in adults with osteoarthritis or post-traumatic arthritis. The efficacy in children or young adults and those with juvenile idiopathic arthritis is less well evidenced.

Clinical notes and radiographs of all patients (n=6) managed with AJD in one tertiary referral centre were retrospectively reviewed. Radiographs were taken pre-surgery, intra-operatively, 1 month following frame removal and at the last follow up, tibiotalar joint space was assessed using ImageJ software. Measurements were taken at the medial, middle and lateral talar dome using frame components as reference. Radiographic data for patients with a good clinical outcome was compared with those who did not.

At time of surgery mean age was 16.1 years (12 – 25 years). Mean follow up was 3.4 years (1.5 – 5.9 years). Indications were juvenile idiopathic arthritis (4) post-traumatic (1) and post-infective arthritis (1). Three patients at last follow up had a good clinical outcome. Two patients required revision to arthrodesis (1.3 and 2.4 years following distraction). One patient had spontaneous fusion. One patient required oral antibiotics for pin site infection.

Inter-observer reliability was 95%. Mean joint space was 1.17mm (SD = 0.87mm) pre-operatively which increased to 6.72mm (SD = 2.23mm) at the time of distraction and 2.09mm (SD = 1.14mm) at the time of removal. At one-year follow up, mean joint space was 1.96mm (SD = 1.97mm).

Outcomes following AJD in this population are variable although significant benefits were demonstrated for 50% of the patients in this series. Radiographic joint space preoperatively did not appear to be associated with need for arthrodesis. Further research in larger groups of young patients is required.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 144 - 144
11 Apr 2023
Lineham B Altaie A Harwood P McGonagle D Pandit H Jones E
Full Access

Multiple biochemical biomarkers have been previously investigated for the diagnosis, prognosis and response to treatment of articular cartilage damage, including osteoarthritis (OA). Synovial fluid (SF) biomarker measurement is a potential method to predict treatment response and effectiveness. However, the significance of different biomarkers and their correlation to clinical outcomes remains unclear. This systematic review evaluated current SF biomarkers used in investigation of cartilage degeneration or regeneration in the knee joint and correlated these biomarkers with clinical outcomes following cartilage repair or regeneration interventions.

PubMed, Institute of Science Index, Scopus, Cochrane Central Register of Controlled Trials, and Embase databases were searched. Studies evaluating SF biomarkers and clinical outcomes following cartilage repair intervention were included. Two researchers independently performed data extraction and QUADAS-2 analysis. Biomarker inclusion, change following intervention and correlation with clinical outcome was compared.

9 studies were included. Study heterogeneity precluded meta-analysis. There was significant variation in sampling and analysis. 33 biomarkers were evaluated in addition to microRNA and catabolic/anabolic ratios. Five studies reported on correlation of biomarkers with six biomarkers significantly correlated with clinical outcomes following intervention. However, correlation was only demonstrated in isolated studies.

This review demonstrates significant difficulties in drawing conclusions regarding the importance of SF biomarkers based on the available literature. Improved standardisation for collection and analysis of SF samples is required. Future publications should also focus on clinical outcome scores and seek to correlate biomarkers with progression to further understand the significance of identified markers in a clinical context.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 34 - 34
1 Dec 2021
Elkington R Beadling A Hall R Pandit H Bryant M
Full Access

Abstract

Objectives

Current use of hard biomaterials such as cobalt-chrome alloys or ceramics to articulate against the relatively soft, compliant native cartilage surface reduces the joint contact area by up to two thirds. This gives rise to high and abnormal loading conditions which promotes degradation and erosion of the mating cartilage leading to pain, stiffness, and loss of function. Biomimetic soft lubrication strategies have been developed by grafting hydrophilic polymers onto substrates to form a gel-type surface. Surface grafted gels mimic the natural mechanisms of friction dissipation in synovial joints, showing a promising potential for use in hemiarthroplasty. This project aims to develop implant surfaces with properties tailored to match articular cartilage to retain and promote natural joint function ahead of total joint replacement.

Methods

Four different types of monomers were grafted in a one-step photopolymerisation procedure onto polished PEEK substrates. The functionalised surfaces were investigated using surface wettability, FTIR, and simplified 2D-tribometry tests against glass and animal cartilage specimens to assess their lubricity and mechanical properties for hemiarthroplasty articulations.


Abstract

Objective

To compare the periprosthetic fracture mechanics between a collared and collarless fully coated cementless femoral stem in a composite femur.

Methods

Two groups of six composite femurs (‘Osteoporotic femur’, SawBones, WA USA) were implanted with either a collared (collared group) or collarless (collarless group) cementless femoral stem which was otherwise identical by a single experienced surgeon. Periprosthetic fractures of the femur were simulated using a previously published technique. High speed video recording was used to identify fracture mechanism. Fracture torque and angular displacement were measured and rotational work and system stiffness were estimated for each trial. Results were compared between collared and collarless group and the comparison was evaluated against previously published work using fresh frozen femurs and the same protocol.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 19 - 19
1 Mar 2021
Lamb J Coltart O Adekanmbi I Stewart T Pandit H
Full Access

Abstract

Objective

To estimate the effect of calcar collar contact on periprosthetic fracture mechanics using a collared fully coated cementless femoral stem.

Methods

Three groups of six composite femurs were implanted with a fully coated collared cementless femoral stem. Neck resection was increased between groups (group 1 = normal, group 2 = 3mm additional, group 3 = 6mm additional), to simulate failure to obtain calcar collar contact. Periprosthetic fractures of the femur were simulated using a previously published technique. Fracture torque and rotational displacement were measured and torsional stiffness and rotational work prior to fracture were estimated. High speed video recording identified if collar to calcar contact (CCC) occurred. Results between trials where calcar contact did and did not occur where compared using Mann-Whitney U tests.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 41 - 41
1 Mar 2021
Lamb J Coltart O Adekanmbi I Stewart T Pandit H
Full Access

Abstract

Objective

To estimate the effect of calcar collar separation on the likelihood of calcar collar contact during in vitro periprosthetic fracture.

Methods

Three groups of six composite femurs were implanted with a collared cementless femoral stem. Neck resection was increased between groups (group 1 = normal, group 2 = 3mm additional, group 3 = 6mm additional), to simulate failure to obtain calcar collar contact. Prior to each trial, the distances between anterior (ACC) and posterior (PCC) collar and the calcar were measured. Periprosthetic fractures of the femur were simulated using a previously published technique. High speed video recording identified when collar to calcar contact (CCC) occurred. The ACC and PCC were compared between trials where the CCC was and was not achieved. Regression estimated the odds of failing to achieve CCC for a given ACC or PCC.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 27 - 27
1 Mar 2021
van Duren B Lamb J Al-Ashqar M Pandit H Brew C
Full Access

The angle of acetabular inclination is an important measurement in total hip replacement (THR) procedures. Determining the acetabular component orientation intra-operatively remains a challenge. An increasing number of innovators have described techniques and devices to achieve it. This paper describes a mechanical inclinometer design to measure intra-operative acetabular cup inclination. Then, the mechanical device is tested to determine its accuracy. The aim was to design an inclinometer to measure inclination without existing instrumentation modification. The device was designed to meet the following criteria: 1. measure inclination with acceptable accuracy (+/− 5o); 2. easy to use intra-operatively (handling & visualization); 3. adaptable and useable with majority of instrumentation kits without modification; 4. sterilizable by all methods; 5. robust/reusable.

The prototype device was drafted by computer aided design (CAD) software. Then a prototype was constructed using a 3D printer to establish the final format. The final device was CNC machined from SAE 304 stainless steel. The design uses an eccentrically weighted flywheel mounted on two W16002-2RS ball bearings pressed into symmetrical housing components. The weighted wheel is engraved with calibrated markings relative to its mass centre. Device functioning is dependent on gravity maintaining the weighted wheel in a fixed orientation while the housing can adapt to the calibration allowing for determining the corresponding measurement. The prototype device accuracy was compared to a digital device. A digital protractor was used to create an angle. The mechanical inclinometer (user blinded to digital reading) was used to determine the angle and compared to the digital reading.

The accuracy of the device compared to the standard freehand technique was assessed using a saw bone pelvis fixed in a lateral decubitus position. 18 surgeons (6 expert, 6 intermediate, 6 novice) were asked to place an uncemented acetabular cup in a saw bone pelvis to a target of 40 degrees. First freehand then using the inclinometer. The inclination was determined using a custom-built inertial measurement unit with the user blinded to the result. Comparison between the mechanical and digital devices showed that the mechanical device had an average error of −0.2, a standard deviation of 1.5, and range −3.3 to 2.6. The average root mean square error was 1.1 with a standard deviation of 0.9. Comparison of the inclinometer to the freehand technique showed that with the freehand component placement 50% of the surgeons were outside the acceptable range of 35–45 degrees. The use of the inclinometer resulted all participants to achieve placement within the acceptable range. It was noted that expert surgeons were more accurate at achieving the target inclination when compared to less experienced surgeons.

This work demonstrates that the design and initial testing of a mechanical inclinometer is suitable for use in determining the acetabular cup inclination in THR. Experimental testing showed that the device is accurate to within acceptable limits and reliably improved the accuracy of uncemented cup implantation in all surgeons.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 125 - 125
1 Jul 2014
Boissonneault A Lynch J Wise B Segal N Gross D Nevitt M Murray D Pandit H
Full Access

Summary

Anatomical variations in hip joint anatomy are associated with both the presence and location of tibiofemoral osteoarthritis (OA).

Introduction

Variations in hip joint anatomy can alter the moment-generating capacity of the hip abductor muscles, possibly leading to changes in the magnitude and direction of ground reaction force and altered loading at the knee. Through analysis of full-limb anteroposterior radiographs, this study explored the hypothesis that knees with lateral and medial knee OA demonstrate hip geometry that differs from that of control knees without OA.