Luc R Favard L Guery J Sirveaux F Oudet D Mole D Walch G
Full Access

Over the long term, the results of the insertion of a Grammont inverted shoulder prothesis are unknown. The present study reports survivorship curves and the role of the initial aetiology in patients re-examined after 5 to 10 years.

Patients and methods Eighty prostheses (for 77 patients) were implanted between 1992 and 1998: 66 cases of massive cuff tear arthropathy (MCTA) and 24 cases for another aetiology (mainly rheumatoid arthritis and revision).

At the time of follow-up, 18 patients had died and 2 could not be traced. The remaining patients (57 representing 60 prostheses) were seen by an independent examiner. The minimum follow-up was 5 years. The average follow-up was 69,6 months.

Kaplan-Meir survivorship curves for the 60 prostheses were established in order to show the probability of failure as defined by: revision of the prothesis, glenoid loosening, and a functional level< 30 points according to the Constant score.

Results The survivorship curves were as follow:

- for non revision of the prosthesis at 10 years: 91% overall; after 9 years: 95% for MCTA, and 77 % for the others aetiologies. This difference was statistically significant (p< 0,01) ; 6 implants were revised: 3 for MCTA and 3 for other aetiologies.

- for non glenoid loosening at 10 years: 84 % overall ; after 7 years: 91% for MCTA and 77% for other aetiologies. This difference was statistically significant (p< 0,05). In addition to the cases of replaced implants mentioned above there was a case of glenoid loosening after 8 years follow-up in a patient aged 92.

-for Constant score < 30 at 10 years: 58 % overall. The punctual survivorship rate was significantly different in function of the aetiology, at 6 years ; but this was no longer the case after 7 years.

Discussion

According to revision of the prosthesis, there is a clear rupture in the survivorship curve about 3 years after insertion in aetiologies other than MCTA. This suggests that Grammont inverted total shoulder arthroplasty is not appropriate in these aetiologies (particularly in cases of rheumatoid arthritis).

According to Constant score < 30, there is a clear rupture in the survivorship curve about 7 years after insertion specially in MCTA cases. This suggests that inverted protheses should be used only in cases with severe handicap and only in patients aged over 75.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 119 - 119
1 Apr 2005
Favard L Sirveaux F Huguet D Oudet D Molé D
Full Access

Purpose: Preoperative morphology must be carefully assessed for proper surgical planning for patients with arthroplasty with massive rotator cuff tears, but many morphological aspects are poorly understood. The purpose of this study was to assess the technical implications of this situation.

Material and methods: We included patients with arthropathy with massive rotator cuff tears who had a complete clinical and radiographic preoperative work-up. We analysed the morphological aspects of the acromion, the humerus and the glenoid cavity.

Results: One hundred forty-two patients (148 shoulders) were included. The acromion presented a fracture or lysis in 13 shoulders and was thinned or had an imprint in 37. It was normal in 70 and hypertrophic in 16. The humerus showed signs of necrosis in 31 shoulders, with a washed out trochiter in 7. Glenoid wear was classed in four stages: E0 or normal glenoid (n=51), E1 or centred wear (n=32), E2 or biconcave aspect (n=46), and E3 or major wear with superior concavity (n=13). Inverted prostheses were implanted in 80 shoulders and non-constrained prostheses in 68. The non-constrained prostheses exhibited progressive ascension of the humeral head in 63% with wear of the glenoid vault. Clinical deterioration led to revision in two patients. The non-constrained prostheses inserted in patients with an E2 glenoid had a significantly lower Constant score (p< 0.05) than the others. A notch appeared in the scapular column in 65%; of the constrained prostheses. This notch was favoured significantly in glenoids classed E2 or E3 preoperatively. The preoperative aspect of the humerus did not appear to affect clinical and radiographic outcome.

Discussion: A thin or lysed acromion associated with an E2 glenoid constitutes a poor indication for non-constrained prosthesis. In this situation, an inverted prosthesis should be used taking care to avoid orienting the glenosphere upwardly, a technically difficult task. Good indications for non-contrained prostheses should probably be limited to shoulders with a normal or thickened acromion and and E1 glenoid.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 388 - 395
1 Apr 2004
Sirveaux F Favard L Oudet D Huquet D Walch G Mole D

We reviewed 80 shoulders (77 patients) at a mean follow-up of 44 months after insertion of a Grammont inverted shoulder prosthesis. Three implants had failed and had been revised. The mean Constant score had increased from 22.6 points pre-operatively to 65.6 points at review. In 96% of these shoulders there was no or only minimal pain. The mean active forward elevation increased from 73° to 138°. The integrity of teres minor is essential for the recovery of external rotation and significantly influenced the Constant score. Five cases of aseptic loosening of the glenoid and seven of dissociation of the glenoid component were noted.

This study confirms the promising early results obtained with the inverted prosthesis in the treatment of a cuff-tear arthropathy. It should be considered in the treatment of osteoarthritis with a massive tear of the cuff but should be reserved for elderly patients.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 230 - 230
1 Mar 2004
Favard L Sirveaux F Oudet D Huguet D Mole D
Full Access

Aim: To compare results of hemi arthroplasty (Aequalis) and reverse arthroplasty (Delta) in treatment of arthropathy with massive cuff tear.

Methods: This was a multicentric study included 142 shoulder arthroplasties (80 reverse and 62 hemiarthroplasties). The pre-op. status was similar in two population according to Constant score, active anterior elevation (AAE) and active external rotation (AER).

Results: The patients were evaluated with a mean follow-up of 44 months. There were 7 failures needed 5 revisions (2 in hemi group and 3 in reverse one). The Constant score was significantly better (p< 0,01) in reverse group (65.6) than in hemi group (46.2). AAE was significantly better (p< 0,01) in reverse group (138°) than in hemi group (96°). AER was significantly better (p< 0,05) in hemi group (22°) than in reverse group (11°) but external rotation in elevated position and internal rotation were not different. These results stay similar even with a follow up over 5 years. In reverse group, partial glenoid unscrewing was observed in 3 patients, and a notch in pillar of scapula in 50 cases. In hemi group, upward migration was observed in 32 cases.

Conclusions: We found significantly better results for reverse prostheses. The inherent risk of hemiarthroplasties is upward migration wearing the coraco acromialarch. The inherent risk of reverse prosthesis is the notch in scapula, and the strain on glenoid fixation, but the results over 5 years stay satisfactory.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 29 - 30
1 Jan 2004
Favard L Sirveaux F Oudet D Huguet D Molé D
Full Access

Purpose: The purpose of this work was to compare outcome after hemiarthroplasty and after inverted arthroplasty for the treatment of excentred degeneration of the shoulder joint.

Material and methods: This multicentric study inclued 136 patients, 110 women and 26 men, mean age 72.4 years (range 55 – 86 years) with 142 shoulder prostheses. Among the 142 shoulders operated on, 62 underwent Aequalis hemiarthroplasty and 80 inverted arthroplasty. The preoperative handicap was more severe in the hemiarthroplasty group (Constant score 26) than in the inverted arthroplasty group (Constant score 23).

Results: Clinical and radiological follow-up data were collected at a mean follow-up of 44 months for the Aequalis prostheses and at 45 months for the inverted prostheses. There were seven failures requiring five revision procedures: three in the hemiarthroplasty group and four in the inverted arthroplasty group.

The differences between the hemi- and inverted arthroplasty groups concerned the Constant score, which was significantly better in the inverted prostheses (65.5) than in the hemiarthroplasties (46.1), for all subscores. Active elevation was 138° for the inverted prostheses and 97° for the Aequalis prostheses (p < 0.01). Mean external rotation in position 1 was 22° for the Aequalis prostheses and 11° for the inverted prostheses (p < 0.01) with no difference in elevation rotation. These results remained equivalent and significant over time, even beyond five years.

Radiographically, there was one case with an anomalous humeral component (impaction) in the inverted group. For the inverted prostheses, there were three migrations that have not been revised to date and three partial screw loosenings. The main problem was the development of notches in the scapular column observed in 50% of the cases including 20% which reached the lower screw. For the Aequalis prostheses, the main problem was deterioration of the acromial vault observed in 50% of the cases leading to altered function.

Discussion: Inverted prostheses provide clearly better mid-term results, even after five years. With hemiarthroplasty there is a long-term risk of vault wear. The long-term course of the inverted prostheses is worrisome due to the notches in the scapular column and the stress on the fixation. These prostheses should be used preferably for old persons with a deteriorated vault.