header advert
Results 1 - 10 of 10
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 13 - 13
24 Nov 2023
Sliepen J Hoekstra H Onsea J Bessems L Depypere M Herteleer M Sermon A Nijs S Vranckx J Metsemakers W
Full Access

Aim

The number of operatively treated clavicle fractures has increased over the past decades. Consequently, this has led to an increase in secondary procedures required to treat complications such as fracture-related infection (FRI). The primary objective of this study was to assess the clinical and functional outcome of patients treated for FRI of the clavicle. The secondary objectives were to evaluate the healthcare costs and propose a standardized protocol for the surgical management of this complication.

Method

All patients with a clavicle fracture who underwent open reduction and internal fixation (ORIF) between 1 January 2015 and 1 March 2022 were retrospectively evaluated.

This study included patients with an FRI who were diagnosed and treated according to the recommendations of a multidisciplinary team at the University Hospitals Leuven, Belgium.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_14 | Pages 36 - 36
1 Dec 2019
Depypere M Moonen C Alaerts R Hoekstra H Sermon A Nijs S Metsemakers W
Full Access

Aim

Negative-pressure wound therapy (NPWT) is often propagated as treatment option for fracture-related infection (FRI). After surgical debridement and repeated NPWT dressing changes, the wounds are often closed by free flaps. Sometimes even healing by secondary intention seems an alternative. Recently, concerns have been raised on the long-term use of NPWT as it could be related to bacterial overgrowth and possible re-infection. The purpose of this study was to conduct a retrospective evaluation of the influence of long-term NPWT on tissue culture results and outcome in FRI patients

Method

Between January 1st, 2015 and December 31st, 2018, a total of 852 patients were treated with NPWT for different indications on the Department of Trauma Surgery. Inclusion criteria for this study were patients with a closed fracture, stabilized with osteosynthetic fixation and complicated with a confirmed FRI according to the FRI consensus definition. Patients were included when they received at least three NPWT dressing changes in the operating room. Exclusion criteria were patients younger than 18 years, or the absence of cultures results from dressing changes.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 89 - 89
1 Dec 2018
Morgenstern M Vallejo A McNally M Moriarty F Ferguson J Nijs S Metsemakers W
Full Access

Aim

Alongside debridement and irrigation, soft tissue coverage and osseous stabilization, systemic antibiotic prophylaxis is considered the gold standard in the management of open fractures and considerably reduces the risk of subsequent fracture-related Infections (FRI). The direct application of antibiotics into the surgical field (local antibiotics) has been used for decades as additional prophylaxis in open fractures, although definitive evidence confirming a beneficial effect is scarce. The purpose of the present study was to review the clinical evidence regarding the effect of prophylactic application of local antibiotics in open limb fractures.

Method

A comprehensive literature search was performed in PubMed, Web-of- Science and Embase. Cohort studies investigating the effect of additional local antibiotic prophylaxis compared to systemic prophylaxis alone in the management of open fractures were included and the data were pooled in a meta-analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_17 | Pages 16 - 16
1 Dec 2018
Declercq P Nijssen A Quintens J De Ridder T Merten B Mesure J Nijs S Zalavras C Spriet I Metsemakers W
Full Access

Aim

Duration of perioperative antimicrobial prophylaxis (PAP) remains controversial in prevention of fracture-related infection (FRI) – with rates up to 30% - in open fracture (OF) management. Objectives were to investigate the impact of the PAP duration exclusively in or related to long bone OF trauma patients and the influence of augmented renal clearance (ARC), a known phenomenon in trauma patients, as PAP consists of predominantly renally eliminated antibiotics.

Method

Trauma patients with operatively treated OF, admitted between January 2003 and January 2017 at the University Hospitals Leuven, were retrospectively evaluated. FRI was defined following the criteria of the consensus definition of FRI. A logistic regression model was conducted with FRI as outcome. Results were considered statistically significant when p< 0.05.


Bone & Joint Research
Vol. 7, Issue 7 | Pages 447 - 456
1 Jul 2018
Morgenstern M Vallejo A McNally MA Moriarty TF Ferguson JY Nijs S Metsemakers W

Objectives

As well as debridement and irrigation, soft-tissue coverage, and osseous stabilization, systemic antibiotic prophylaxis is considered the benchmark in the management of open fractures and considerably reduces the risk of subsequent fracture-related infections (FRI). The direct application of antibiotics in the surgical field (local antibiotics) has been used for decades as additional prophylaxis in open fractures, although definitive evidence confirming a beneficial effect is scarce. The purpose of the present study was to review the clinical evidence regarding the effect of prophylactic application of local antibiotics in open limb fractures.

Methods

A comprehensive literature search was performed in PubMed, Web of Science, and Embase. Cohort studies investigating the effect of additional local antibiotic prophylaxis compared with systemic prophylaxis alone in the management of open fractures were included and the data were pooled in a meta-analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 73 - 73
1 Apr 2018
Vancleef S Herteleer M Herijgers P Nijs S Jonkers I Vander Sloten J
Full Access

Last decade, a shift towards operative treatment of midshaft clavicle fractures has been observed [T. Huttunen et al., Injury, 2013]. Current fracture fixation plates are however suboptimal, leading to reoperation rates up to 53% [J. G. Wijdicks et al., Arch. Orthop. Trauma Surg, 2012]. Plate irritation, potentially caused by a bad geometric fit and plate prominence, has been found to be the most important factor for reoperation [B. D. Ashman et a.l, Injury, 2014]. Therefore, thin plate implants that do not interfere with muscle attachment sites (MAS) would be beneficial in reducing plate irritation. However, little is known about the clavicle MAS variation. The goal of this study was therefore to assess their variability by morphing the MAS to an average clavicle.

14 Cadaveric clavicles were dissected by a medical doctor (MH), laser scanned (Nikon, LC60dx) and a photogrammetry was created with Agisoft photoscan (Agisoft, Russia). Subsequently a CT-scan of these bones was acquired and segmented in Mimics (Materialise, Belgium). The segmented bone was aligned with the laser scan and MAS were indicated in 3-matic (Materialise, Belgium). Next, a statistical shape model (SSM) of the 14 segmented clavicles was created. The average clavicle from the SSM was then registered to all original clavicle meshes. This registration assures correspondences between source and target mesh. Hence, MAS of individual muscles of all 14 bones were indicated on the average clavicle.

Mean area is 602 mm2 ± 137 mm2 for the deltoid muscle, 1022 mm2 ±207 mm2 for the trapezius muscle, and 683 mm2 ± 132 mm2 for the pectoralis major muscle. The sternocleidomastoid muscle has a mean area of 513 mm2 ± 190 mm2 and the subclavius muscle had the smallest mean area of 451 mm2 ± 162 mm2. Visualization of all MAS on the average clavicle resulted in 72% coverage of the surface, visualizing only each muscle's largest MAS led to 52% coverage.

The large differences in MAS surface areas, as shown by the standard deviation, already indicate their variability. Difference between coverage by all MAS and only the largest, shows that MAS location varies strongly as well. Therefore, design of generic plates that do not interfere with individual MAS is challenging. Hence, patient-specific clavicle fracture fixation plates should be considered to minimally interfere with MAS.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 78 - 78
1 Dec 2016
Metsemakers W Smeets B Nijs S Hoekstra H
Full Access

Aim

The objective of this study was to define hospital-related healthcare costs associated with infection after fracture fixation (IFF) of the tibia and identify the subset of clinical variables relevant in driving these costs within the Belgium's healthcare system.

Method

Between January 1st 2009 and January 1st 2014, a total of 358 patients treated operatively for AO type 41, 42 and 43 tibial fractures, were included in this study. The calculated costs were related to the Belgium's healthcare financing context and limited to costs induced by hospital related care. Five main hospital-related cost categories were studied: honoraria, materials, hospitalization, day care admission, and pharmaceuticals. In addition, a total of 19 clinical and process variables were defined.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 151 - 151
1 Sep 2012
Nijs S Hardeman F
Full Access

Introduction

Analysing the results of angular stable osteosynthesis in large groups of patients can give us an indication of the possibilities and limitations of both angular stable nailing and plating.

Material and Methods

Fractures have been classified using the AO-classification system.

To judge vascularisation of the head fragment we use the criteria as described by Hertel.

We considered fracture reduction as adequate when the CCD-angle could be restored, with a maximum of 10° varus or valgus malalignment and a maximal persistent tuberosity displacement equal to or less than 3 mm in any direction.

An independent investigator collects information on reoperations based on: patient interview, hospital data and contact with the operating surgeon if the revision took place elsewhere. Reoperation is defined as any secondary surgical procedure after the initial open reduction and fixation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 274 - 274
1 Jul 2011
Corten K Van Rykel F Sermon A Vanderschot P Nijs S Bellemans J Reynders P Simon J Broos P
Full Access

Purpose: Plate and cable alone constructs to treat periprosthetic fractures around a well-fixed femoral stem in total hip replacements, have been reported with high failure rates. The aim of this study was to evaluate the results of our surgical treatment algorithm to reliably use lateral plate and cable constructs in these fractures.

Method: One hundred and six periprosthetic fractures in 102 patients were treated between 1996 and 2006. Forty-five fractures were pre-operatively assessed as Vancouver type B1 fractures. The joint was always dislocated and stability of the implant was meticulously evaluated. This led to the identification of nine (20%) unstable stems leaving 36 fractures to be real B1-type fractures. The fracture was considered to be suitable for lateral plate and cable alone fixation if the medial cortex was not comminuted and an anatomical reduction of the medial cortex could be achieved. Twenty-nine B1- and 5 C-type fractures had been treated with a single lateral plate and cable construct. The mean length of follow-up was 43.2 months. The paired Student’s T-test with a confidence interval of 95% and a significant p-value of p< 0.05 was used to compare the pre- and postoperative UCLA hip scores.

Results: Four (12%) patients died within one month from surgery leaving 30 patients for follow-up. Twenty-nine fractures united at a mean of 6.4 months. One B1-type construct failed due to inappropriate proximal fixation. Two fractures united uneventfully with a mean of 8° of varus alignment of the proximal fragment. One patient with a C-type fracture sustained a fracture distal to the tip of the plate. There were three plate infections (8.8%). There was no significant difference between the pre- and post-operative UCLA hip scores (25 versus 23 resp.).

Conclusion: These fractures represent a difficult problem with a high complication rate of 30%. The presented treatment algorithm contributed significantly to the 97% union rate with plate and cable alone constructs that was comparable to the union rates achieved with combined plate and strut graft fixation.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 571 - 571
1 Oct 2010
Dietz S Nijs S Rommens P Sternstein W
Full Access

The aim of our biomechanical study was to find out whether the prosthetic design, especially of the metaphyseal part, and the type of tuberosity fixation influences the primary stability in shoulder arthroplasty.

Materials and Methods: 16 fresh frozen human cadaveric humeri were dissected until only the rotator cuff remained. A four-part fracture was simulated by osteotomy. In a first step two types of shoulder prosthesis (open stem versus closed stem) were used. The Tornier Aequalis prosthesis (open stem) using suture fixation and the Mathys Affinis fracture prosthesis (closed stem) using cable fixation were implanted according to standard techniques. The specimens were then loaded into a servo-pneumatic testing device in 25° of abduction. In 20 consecutive cycles traction of 40 Newton was alternating exerted on the subscapularis and infraspinatus tendon, while a continuous force of 40 Newton was exerted on the greater tuberosity to simulate the pull of the m. supraspinatus. The motion of the fragments was recorded by 2 high speed cameras. The following parameters were investigated : Failure of osteosynthesis, intertuberosity motion, motion lesser tuberosity-shaft, motion greater tuberosity-shaft, motion metaphysis-shaft. After completing the first series the cable fixation exposed to be more stable. In a second series we compared cable versus suture fixation in the Affinis fracture prosthesis to find out whether the stability was depending on the prosthesis design.

Results:

Series 1: The intertuberosity motion was significantly lower in the cable prosthesis. The tuberosity-shaft motion was significantly lower in the cable group for greater and lesser tuberosity. The metaphysis - shaft motion did not significantly differ in both groups.

Series 2: The intertuberosity motion was significant lower when the tuberosities were fixed by cable. The tuberosity-shaft motion was significantly lower when cable fixation was used. The metaphysis-shaft motion was not significantly diverse.

Conclusion: Highest primary stability of tuberosity fixation in trauma-arthroplasty of the shoulder was measured in cable fixation and closed stem. We proved that the kind of fixation was the most important factor determing the stability. Metaphyseal design was less important.