header advert
Results 1 - 20 of 179
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_18 | Pages 16 - 16
1 Dec 2023
Saghir R Watson K Martin A Cohen A Newman J Rajput V
Full Access

Introduction

Knee arthroscopy can be used for ligamentous repair, reconstruction and to reduce burden of infection. Understanding and feeling confident with knee arthroscopy is therefore a highly important skillset for the orthopaedic surgeon. However, with limited training or experience, furthered by reduced practical education due to COVID-19, this skill can be under-developed amongst trainee surgeons.

Methods

At a single institution, ten junior doctors (FY1 to CT2), were recruited as a part of a five, two-hour session, training programme utilising the Simbionix® ARTHRO Mentor knee arthroscopy simulator, supplemented alongside educational guidance with a consultant orthopaedic knee surgeon. All students had minimal to no levels of prior arthroscopic experience. Exercises completed included maintaining steadiness, image centring and orientation, probe triangulation, arthroscopic knee examination, removal of loose bodies and meniscectomy. Pre and post experience questionnaires and quantitative repeat analysis on simulation exercises were undertaken to identify levels of improvement.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 58 - 58
7 Aug 2023
Saghir R Watson K Martin A Cohen A Newman J Rajput V
Full Access

Abstract

Introduction

Knee arthroscopy can be used for ligamentous repair, reconstruction and to reduce burden of infection. Understanding and feeling confident with knee arthroscopy is therefore a highly important skillset for the orthopaedic surgeon. However, with limited training or experience, furthered by reduced practical education due to COVID-19, this skill can be under-developed amongst trainee surgeons.

Methods

At a single institution, ten junior doctors (FY1 to CT2), were recruited as a part of a five, two-hour session, training programme utilising the Simbionix® ARTHRO Mentor knee arthroscopy simulator, supplemented alongside educational guidance with a consultant orthopaedic knee surgeon. All students had minimal to no levels of prior arthroscopic experience. Exercises completed included maintaining steadiness, image centering and orientation, probe triangulation, arthroscopic knee examination, removal of loose bodies, and meniscectomy. Pre and post-experience questionnaires and quantitative repeat analysis on simulation exercises were undertaken to identify levels of improvement.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 14 - 14
17 Apr 2023
Bartolo M Newman S Dandridge O Provaggi E Accardi M Dini D Amis A
Full Access

No proven long-term joint-preserving treatment options exist for patients with irreparable meniscal damage. This study aimed to assess gait kinematics and contact pressures of novel fibre-matrix reinforced polyvinyl alcohol-polyethylene glycol (PVA-PEG) hydrogel meniscus implanted ovine stifle joints against intact stifles in a gait simulator.

The gait simulator controlled femoral flexion-extension and applied a 980N axial contact force to the distal end of the tibia, whose movement was guided by the joint natural ligaments (Bartolo; ORS 2021;p1657- LB). Five right stifle joints from sheep aged >2 years were implanted with a PVA-PEG total medial meniscus replacement, fixed to the tibia via transosseous tunnels and interference screws. Implanted stifle joint contact pressures and kinematics in the simulator were recorded and compared to the intact group. Contact pressures on the medial and lateral condyles were measured at 55° flexion using Fujifilm Prescale Low Pressure film inserted under the menisci. 3D kinematics were measured across two 30 second captures using the Optotrak Certus motion-tracking system (Northern Digital Inc.).

Medial peak pressures were not significantly different between the implanted and intact groups (p>0.4), while lateral peak pressures were significantly higher in the implanted group (p<0.01). Implanted stifle joint kinematics in the simulator did not differ significantly from the intact baseline (p>0.01), except for in distraction-compression (p<0.01).

Our findings show that the fibre-matrix reinforced PVA-PEG hydrogel meniscal replacement restored the medial peak contact pressures. Similar to published literature (Fischenich; ABE 2018;46(11):1–12), the lateral peak pressures in the implanted group were higher than the intact. Joint kinematics were similar across groups, with slightly increased internal-external rotation in the implanted group. These findings highlight the effectiveness of the proposed approach and motivate future work on the development of a total meniscal replacement.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 648 - 655
1 Aug 2022
Yeung CM Bhashyam AR Groot OQ Merchan N Newman ET Raskin KA Lozano-Calderón SA

Aims

Due to their radiolucency and favourable mechanical properties, carbon fibre nails may be a preferable alternative to titanium nails for oncology patients. We aim to compare the surgical characteristics and short-term results of patients who underwent intramedullary fixation with either a titanium or carbon fibre nail for pathological long-bone fracture.

Methods

This single tertiary-institutional, retrospectively matched case-control study included 72 patients who underwent prophylactic or therapeutic fixation for pathological fracture of the humerus, femur, or tibia with either a titanium (control group, n = 36) or carbon fibre (case group, n = 36) intramedullary nail between 2016 to 2020. Patients were excluded if intramedullary fixation was combined with any other surgical procedure/fixation method. Outcomes included operating time, blood loss, fluoroscopic time, and complications. Fisher’s exact test and Mann-Whitney U test were used for categorical and continuous outcomes, respectively.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 23 - 23
1 Jul 2022
Frame M Hauck O Newman M
Full Access

Abstract

Introduction

Tibial tubercle osteotomy (TTO) is a complex surgical procedure with a significant risk of complications, which include nonunion and tibial fracture. To determine whether an additional suture tape augmentation can provide better biomechanical stability compared with standard screw fixation.

Methods

Five matched pairs of human cadaveric knees were divided into 2 groups: the first group underwent standard TTO fixation with 2 parallel screws. The second group underwent a novel fixation technique, in which a nonabsorbable suture tape (FiberTape) in a figure-of-8 construct was added to the standard screw fixation. Tubercular fragment migration of >50% of the initial distalization length was defined as clinical failure Tubercular fragment displacement during cyclic loading and pull-to-failure force were recorded and compared between the 2 groups.


The Bone & Joint Journal
Vol. 103-B, Issue 6 | Pages 1173 - 1173
1 Jun 2021
Alsousou J Oragui E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 644 - 649
1 Apr 2021
Alsousou J Oragu E Martin A Strickland L Newman S Kendrick B Taylor A Glyn-Jones S

Aims

The aim of this prospective cohort study was to evaluate the early migration of the TriFit cementless proximally coated tapered femoral stem using radiostereometric analysis (RSA).

Methods

A total of 21 patients (eight men and 13 women) undergoing primary total hip arthroplasty (THA) for osteoarthritis of the hip were recruited in this study and followed up for two years. Two patients were lost to follow-up. All patients received a TriFit stem and Trinity Cup with a vitamin E-infused highly cross-linked ultra-high molecular weight polyethylene liner. Radiographs for RSA were taken postoperatively and then at three, 12, and 24 months. Oxford Hip Score (OHS), EuroQol five-dimension questionnaire (EQ-5D), and adverse events were reported.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 1 - 1
1 Jul 2020
Fernquest S Palmer A Gimpel M Birchall R Broomfield J Wedatilake T Dijkstra H Lloyd T Pereira C Newman S Carr A Glyn-Jones S
Full Access

Background

Cam morphology develops during adolescence and predisposes individuals to future hip pain and osteoarthritis. An improved understanding of cam development is required to determine whether the process is modifiable.

Hypothesis/Purpose

The aim of this study was to characterise the risk factors, timing, and pathogenesis of cam formation.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 83 - 83
1 Feb 2020
Wolff D Newman J Shah N Morrissey P Conway C Gold R Tretiakov M Sedaghatpour D Pivec R Naziri Q Illical E
Full Access

Purpose

Infections in orthopaedic surgery are costly, debilitating complications. The search for new treatments and prevention strategies has led to the use of antibiotic-filled calcium sulfate (CaS) as a bone void filler that is both safe and effective. The purpose of this study was to examine the available data on the efficacy of this technology.

Methods

A literature search was performed for studies that evaluated the use of antibiotic-loaded CaS cement in orthopaedics published between inception of the databases to 2017. Selected studies included randomized controlled trials (RCTs) and observational studies published in the English language that met the following criteria: 1) patients underwent an orthopaedic procedure; 2) CaS cement with an antibiotic was used; and 3) at least one of our outcomes were mentioned. Outcomes included resolution of infection, complications related to treatment, subsequent surgeries, overall infection rate, fracture union rate, clinical outcomes, and wound complications. A total of 17 studies were included.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 86 - 86
1 Feb 2020
Khondakar N Shah N Murtaugh T Gold R Aylyarov A Pascal S Harb M Newman J Schwartz J Maheshwari A
Full Access

Summary

A meta-analysis was performed to compare rate of SSI after application of chlorhexidine vs. iodine in total joint arthroplasty. Chlorhexidine had significantly lower odds of SSI.

Introduction

Surgical site infections (SSI) are a significant source of morbidity and mortality. The optimal preoperative skin preparation in lower extremity total joint arthroplasty (TJA) remains debatable between chlorhexidine and iodine-containing solutions. This meta-analysis sought compare SSI rates between chlorhexidine cloth application the night before surgery plus povidone-iodine-alcohol (povidone-iodine) solution at surgery or only povidone-iodine at surgery.


The Bone & Joint Journal
Vol. 100-B, Issue 7 | Pages 875 - 881
1 Jul 2018
Newman JM Khlopas A Sodhi N Curtis GL Sultan AA George J Higuera CA Mont MA

Aims

This study compared multiple sclerosis (MS) patients who underwent primary total hip arthroplasty (THA) with a matched cohort. Specifically, we evaluated: 1) implant survivorship; 2) functional outcomes (modified Harris Hip Scores (mHHS), Hip Disability and Osteoarthritis Outcome Score, Joint Replacement (HOOS JR), and modified Multiple Sclerosis Impact Scale (mMSIS) scores (with the MS cohort also evaluated based on the disease phenotype)); 3) physical therapy duration and return to function; 4) radiographic outcomes; and 5) complications.

Patients and Methods

We reviewed our institution’s database to identify MS patients who underwent THA between January 2008 and June 2016. A total of 34 MS patients (41 hips) were matched in a 1:2 ratio to a cohort of THA patients who did not have MS, based on age, body mass index (BMI), and Charlson/Deyo score. Patient records were reviewed for complications, and their functional outcomes and radiographs were reviewed at their most recent follow-up.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 58 - 58
1 Jan 2018
Newman J Khlopas A Sodhi N Curtis G Sultan A Higuera C Mont M
Full Access

Patients who have multiple sclerosis (MS) may be at increased risk of developing complications after total hip arthroplasty (THA). The purpose of this study was to compare: 1) implant survivorship; 2) functional outcomes; 3) complication rates; and 4) radiographic findings after THA between MS patients and a matched cohort.

A single institutional database was reviewed for patients who had a diagnosis of MS and underwent a THA. Thirty-four patients (41 hips) were matched to a 2:1 cohort who did not have MS using based on age, sex, body mass index (BMI), and Charlson/Deyo scores. This resulted in a matching cohort of 80 patients (82 hips). The available medical records were reviewed. Functional outcomes and complications were assessed. Postoperative radiographs were evaluated.

The matching cohort had higher all-cause survivorship at 4-years postoperatively (99 vs. 93%). There were 3 revisions in the MS cohort and 0 revisions in the matching cohort. The MS cohort had lower mHHS scores (66 vs.74 points, p<0.001), lower HOOS JR scores (79 vs. 88 points, p<0.01), required more physical therapy (5 vs. 3 weeks, p<0.01), and took longer to return to their baseline functional level (7 vs. 5 weeks, p<0.05). MS patients had higher rate of complications (6 vs. 1, p<0.05). Excluding revision cases, there was no additional radiographic evidence of progressive radiolucency, loosening, or subsidence.

We found that MS patients had lower implant survivorship, lower functional outcome scores, and increased complication rates. These findings may help orthopaedists to have a better knowledge of how MS patients do after THA.


Bone & Joint Research
Vol. 6, Issue 8 | Pages 522 - 529
1 Aug 2017
Ali AM Newman SDS Hooper PA Davies CM Cobb JP

Objectives

Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain.

Methods

A total of 16 composite tibias were implanted with an Oxford Domed Lateral Partial Knee implant using cutting guides to define tibial slope and resection depth. Four implant positions were assessed: standard (5° posterior slope); 10° posterior slope; 5° reverse tibial slope; and 4 mm increased tibial resection. Using an electrodynamic axial-torsional materials testing machine (Instron 5565), a compressive load of 1.5 kN was applied at 60 N/s on a meniscal bearing via a matching femoral component. Tibial strain beneath the implant was measured using a calibrated Digital Image Correlation system.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 22 - 22
1 Feb 2017
Huixiang W Newman S Jones G Sugand K Cobb J Auvinet E
Full Access

Introduction

Because of the low cost and easy access, surgical video has become a popular method of acquiring surgical skills outside operating rooms without disrupting normal surgical flow. However, currently existing video systems all use a single point of view (POV). Some complex orthopedic procedures, such as joint replacement, require a level of accuracy in several dimensions. So single and fixed POV video may not be enough to provide all the necessary information for educational and training purposes. The aim of our project was to develop a novel multiple POV video system and evaluate its efficacy as an aid for learning joint replacement procedure compared with traditional method.

Materials and Methods

Based on the videos of a hip resurfacing procedure performed by an expert orthopedic surgeon captured by 8 cameras fixed all around the operating table, we developed a novel multiple POV video system which enables users to autonomously switch between optimal viewpoints (Figure 1). 30 student doctors (undergraduate years 3–5 and naive to hip resurfacing procedure) were recruited and randomly allocated to 2 groups: experiment group and control group, and were assigned to learn the procedure using multiple or single POV video systems respectively. Before learning they were first asked to complete a multiple choicetest designed using a modified Delphi technique with the advice and feedback sought from 4 experienced orthopedic surgeons to test the participants' baseline knowledge of hip resurfacing procedure. After video learning, they were asked to answer the test again to verify their gained information and comprehension of the procedure, followed by a 5-point Likert-scale questionnaire to demonstrate their self-perception of confidence and satisfaction with the learning experience. The scores in the 2 tests and in the Likert-scale questionnaire were compared between 2 groups using Independent-Samples t-test (for normally distributed data) or Mann-Whitney U test (for non-normally distributed data). Statistical significance was set as p<0.05.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 884 - 891
1 Jul 2016
Elliott DS Newman KJH Forward DP Hahn DM Ollivere B Kojima K Handley R Rossiter ND Wixted JJ Smith RM Moran CG

This article presents a unified clinical theory that links established facts about the physiology of bone and homeostasis, with those involved in the healing of fractures and the development of nonunion. The key to this theory is the concept that the tissue that forms in and around a fracture should be considered a specific functional entity. This ‘bone-healing unit’ produces a physiological response to its biological and mechanical environment, which leads to the normal healing of bone. This tissue responds to mechanical forces and functions according to Wolff’s law, Perren’s strain theory and Frost’s concept of the “mechanostat”. In response to the local mechanical environment, the bone-healing unit normally changes with time, producing different tissues that can tolerate various levels of strain. The normal result is the formation of bone that bridges the fracture – healing by callus. Nonunion occurs when the bone-healing unit fails either due to mechanical or biological problems or a combination of both. In clinical practice, the majority of nonunions are due to mechanical problems with instability, resulting in too much strain at the fracture site. In most nonunions, there is an intact bone-healing unit. We suggest that this maintains its biological potential to heal, but fails to function due to the mechanical conditions. The theory predicts the healing pattern of multifragmentary fractures and the observed morphological characteristics of different nonunions. It suggests that the majority of nonunions will heal if the correct mechanical environment is produced by surgery, without the need for biological adjuncts such as autologous bone graft.

Cite this article: Bone Joint J 2016;98-B:884–91.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 30 - 30
1 May 2016
Newman S Clarke S Harris S Cobb J
Full Access

Introduction

Patient Specific Instrumentation (PSI) has the potential to allow surgeons to perform procedures more accurately, at lower cost and faster than conventional instrumentation. However, studies using PSI have failed to convincingly demonstrate any of these benefits clinically. The influence of guide design on the accuracy of placement of PSI has received no attention within the literature.

Our experience has suggested that surgeons gain greater benefit from PSI when undertaking procedures they are less familiar with. Lateral unicompartmental knee replacement (UKR) is relatively infrequently performed and may be an example of an operation for which PSI would be of benefit. We aimed to investigate the impact on accuracy of PSI with respect to the area of contact, the nature of the contact (smooth or studded guide surfaces) and the effect of increasing the number of contact points in different planes.

Method

A standard anatomy tibial Sawbone was selected for use in the study and a computed tomography scan obtained to facilitate the production of PSI. Nylon PSI guides were printed on the basis of a lateral UKR plan devised by an orthopaedic surgeon. A control PSI guide with similar dimensions to the cutting block of the Oxford Phase 3 UKR tibial guide was produced, contoured to the anterior tibial surface with multiple studs on the tibial contact surface. Variants of this guide were designed to assess the impact of design features on accuracy. These were: a studded guide with a 40% reduction in tibial contact area, a non-studded version of the control guide, the control guide with a shim to provide articular contact, a guide with an extension to allow distal referencing at the ankle and a guide with a distal extension and an articular shim. All guides were designed with an appendage that facilitated direct attachment to a navigation machine (figure 1). 36 volunteers were asked to place each guide on the tibia with reference to a 3D model of the operative plan. The order of placement was varied using a counterbalanced latin square design to limit the impact of the learning effect. The navigation machine recorded deviations from the plan in respect of proximal-distal and medial-lateral translations as well as rotation around all three axes. Statistical analysis was performed on the compound translational and rotational errors for each guide using ANOVA with Bonferroni correction with statistical significance at p<0.05.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 32 - 32
1 Jan 2016
Carroll K Newman J Holmes A Della Valle AG Cross MB
Full Access

Introduction

Stiffness after total knee arthroplasty is a common occurrence. Despite its prevalence, little is known as to which patients are at risk for poor range of motion after total knee arthroplasty. The purpose of this study was to determine the risk factors for manipulation under anesthesia (MUA) after total knee arthroplasty (TKA).

Methods

Using a single institution registry, 160 patients who underwent a manipulation under anesthesia after total knee arthroplasty between 2007 and 2013 were retrospectively evaluated. Each patient was 1:1 matched by age, gender and laterality to a control group of 160 patients who did not require MUA after TKA. Risk factors for MUA were assessed, and included medical co-morbidities, BMI, prior operations, and preoperative range of motion.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_8 | Pages 6 - 6
1 Feb 2013
Granville-Chapman J Nawaz S Trompeter A Newman K Elliott D
Full Access

Intramedullary nailing of tibial fractures is commonplace and freehand techniques are increasingly popular. The standard freehand method has the knee of the injured leg flexed over a radio-lucent bolster. This requires the imaging C-arm to swing from antero-posterior to lateral position several times. Furthermore, guide wire placement; reaming and nail insertion are all performed well above most surgeons' shoulder height. If instead the leg is hung over the edge of the table, the assistant must crouch and hold the leg until the nail is passed beyond the fracture.

We describe a method of nailing which is easier both for the surgeons and the (often inexperienced) radiographer and present a series of 87 consecutive cases managed with this technique.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 157 - 157
1 Jan 2013
Nawaz S Keightley A Elliott D Newman K Khaleel A
Full Access

Currently the debate continues in definitive fixation method for complex tibial plateau fractures. The aim of surgical management remains prevention of further damage to the articular cartilage, whilst avoiding iatrogenic risks - Low Risk Surgery (LRS). The purpose of this study was to determine the functional impact, clinical radiological outcome following tibial plateau fractures treated with either external fixation or internal fixation.

124 Schatzker IV-VI tibial plateau fractures were reviewed following surgical fixation. Fractures analysed included 24 type IV, 20 type V and 80 type VI tibial plateau fractures. The majority of Schatzker IV fractures were treated with internal fixation, but 67 of 80 Schatzker VI fractures were treated with the Ilizarov method. The average IOWA knee score, was 86 (16 to 100) and the average range of motion was 133 degrees (60 to 150). There were no differences between the circular fixator group and the internal fixation group in terms of range of motion or IOWA scores. There were comparable functional outcomes and complication rates between both groups.

In summary patients with high energy tibial plateau fracture treated with internal or external fixation, have a good chance of achieving satisfactory long term knee function.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 537 - 537
1 Sep 2012
Mohammed R Farook M Newman K
Full Access

We reviewed our results and complications of using a pre-bent 1.6mm Kirschner wire (K-wire) for extra-articular metacarpal fractures. The surgical procedure was indicated for angulation at the fracture site in a true lateral radiograph of at least 30 degrees and/or in the presence of a rotatory deformity.

A single K-wire is pre-bent in a lazy-S fashion with a sharp bend at approximately 5 millimetres and a longer smooth curve bent in the opposite direction. An initial entry point is made at the base of the metacarpal using a 2.5mm drill by hand. The K-wire is inserted blunt end first in an antegrade manner and the fracture reduced as the wire is passed across the fracture site. With the wire acting as three-point fixation, early mobilisation is commenced at the metacarpo-phalangeal joint in a Futuro hand splint.

The wire is usually removed with pliers post-operatively at four weeks in the fracture clinic.

We studied internal fixation of 18 little finger and 2 ring finger metacarpal fractures from November 2007 to August 2009. The average age of the cohort was 25 years with 3 women and 17 men. The predominant mechanism was a punch injury with 5 diaphyseal and 15 metacarpal neck fractures. The time to surgical intervention was a mean 13 days (range 4 to 28 days). All fractures proceeded to bony union. The wire was extracted at an average of 4.4 weeks (range three to six weeks). At an average follow up of 8 weeks, one fracture had to be revised for failed fixation and three superficial wound infections needed antibiotic treatment.

With this simple and minimally invasive technique performed as day-case surgery, all patients were able to start mobilisation immediately.

The general outcome was good hand function with few complications.